• Title/Summary/Keyword: No load temperature

Search Result 241, Processing Time 0.025 seconds

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.

Demonstration Study on Ammonia Stripping in Electronic Industry Wastewater with High Concentrations of Ammonia Nitrogen (고농도 암모니아를 함유한 전자 폐수의 암모니아 탈기 실증 연구)

  • Jae Hyun Son;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.297-304
    • /
    • 2023
  • The rapid advancement of the high-tech electronics industry has led to a significant increase in high-concentration ammonia wastewater. Various methods have been attempted to reliably treat wastewater containing high concentrations of ammonia, but no successful technology has yet been developed and applied. In this study, the removal efficiency and characteristics of ammonia nitrogen was evaluated according to changes in temperature, air loading rate, and liquid loading rate using a closed circulation countercurrent packed tower type demonstration facility for wastewater containing high concentrations of ammonia generated in the high-tech electronics industry. The temperature was varied while maintaining operating conditions of a wastewater flowrate of 20.8 m3 h-1 and an air flow rate of 18,000 Nm3 h-1. The results showed that at temperatures of 45,50,55, and 60℃, the removal efficiencies of ammonia nitrogen (NH3-N) were 87.5%, 93.4%, 96.8%, and 98.7%, respectively. It was observed that temperature had the most significant impact on the removal efficiency of NH3-N under these conditions. As the air loading rate increases, the removal rate also increases, but the increase in removal efficiency is not significant because droplets from the absorption tower flow into the stripping tower. Even if the liquid loading rate was changed by ±30%, the removal rate did not change significantly. This does not mean that the removal rate was unaffected, but was believed to be due to the relatively high air load rate. Through demonstration research, it was confirmed that ammonia stripping is a reliable technology that can stably treat high-concentration ammonia wastewater generated in the high-tech electronics industry.

Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators (프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구)

  • Lim, B.H.;Park, Y.B.;Yoo, H.K.;Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

A Implementation of Acer Pictum Sap Integrated Management System based on Energy Harvesting and Monitoring System (에너지 하베스팅 및 모니터링 기반의 고로쇠 수액 통합 관리 시스템 구현)

  • Jung, SeHoon;Jo, KyeongHo;Kim, JunYeoung;Park, Jun;Kim, JongChan;Choi, SooIm;Sim, ChunBo
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.11
    • /
    • pp.1324-1337
    • /
    • 2019
  • This study set out to investigate an energy harvesting device to ensure stable energy supply to batteries and data collection devices and a monitoring system for acer pictum sap to check collected data. Acer pictum sap farmers have written down weather information and yield of acer pictum sap manually for data storage. Since the job is done manually, there are many missing values in their data. In addition, it is not easy to manage batteries due to the characteristics of the areas where acer pictum sap is collected. The present study thus decided to build an energy harvesting device based on new renewable energy to ensure stable energy supply by taking into consideration power load, daily power consumption, and number of days with no sunshine for various devices. For a monitoring system, the investigator proposed a JSP-based web page to monitor temperature, humidity, volume of collected water, and battery state in real time. The proposed energy harvesting device was applied to reduce missing values in data. It promoted stable energy supply to the batteries and data collection devices, reducing the percentage of missing values in data from 30.55% to 0%.

Development of Control Method for Air-Conditioner as the Resources of DLC (직접부하제어자원으로서 에어컨 주기제어 방법론 개발)

  • Doo, Seog-Bae;Kim, Jeoung-Uk;Kim, Hyeong-Jung;Kim, Hoi-Cheol;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.145-147
    • /
    • 2005
  • This paper presents a methodology for satisfying the thermal comfort of Indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. KEPCO(Korea Electric Power Corporation) use the fixed duty cycle control method regardless of the indoor thermal environment. This method has disadvantages that energy saying depends on the set-point value of the Air-Conditioner and DLC has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. A variable duty cycle estimates the PMV(Predict Mean Vote) at the next step with a predicted temperature and humidity coming from the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. The proposed methodology uses the historical real data of Sep. 7th, 2001 from a classroom in seoul to verify the effectiveness of the variable duty cycle method comparing with fixed duty cycle. The result shows that the variable duty cycle reduces the peak demand to 2.6times more than fixed duty cycle and increases the load control ratio by 8% more. Based on the variable duty cycle control algorithm, the effectiveness of DLC is much more improved as compared with the fixed duty cycle.

  • PDF

A Study on the Effect of Trim on the Resistance in a Small Coastwise Passenger Boat (소형연안객선(小型沿岸客船)의 Trim변화(變化)가 저항(抵抗)에 미치는 영향(影響))

  • J.H.,Hwang;K.J.,Bai
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.4 no.1
    • /
    • pp.49-54
    • /
    • 1967
  • The authors considered the effects of trim in the small coastal passenger boat upon resistance in this paper. Any change of trim no matter how small, necessarily produces some effect upon resistance. The relations between the resistance coefficients and trim were investigated through the towing test of the Model $MCI-P_1-65$, Korean Standardized Ship, GT 70 tons passenger boat in the gravitational tank. The Lines of the Model are given in Fig. 1. Principal dimensions and other characteristics vary with the trim in general. Those values varied with the trim for $MCI-P_1-65$ are tabulated in table 1. The resistance was measured at five conditions such as even keel, 0.0273L, (original designed trim) 0.0473L, 0.0663L, 0.0873L trim by the stern, fixing the displacement corresponding to the designed load water line. Model was made of wood in length of 3.5 feet coated with varnish, and without appendages. As the artificial turbulent stimulator, the sand strip method was used. The results of model towing tests, correcting to water temperature of $70^{\circ}F$, were expanded to full scale using the Schoenherr's friction formula and surface roughness allowance coefficient of 0.0004. The authors point out, the following results. 1) Optimum trim which gives the minimum resistance exists for every speed at constant displacement and each comes to the same value. For $MCI-P_1-65$ optimum trim is 0.0673L trim by the stern(Fig.4-The cross curves of the resistancecoefficients). 2) At constant displacement, when LCB(longitudinal position of center of buoyancy) varies with the trim, there exists optimum value of LCB which gives minimum resistance for every speed and each comes to the same value. For $MCI-P_1-65$ optimum position of LCB is 8%L aft from midship section (Fig.6).

  • PDF

Effect of light-curing, pressure, oxygen inhibition, and heat on shear bond strength between bis-acryl provisional restoration and bis-acryl repair materials

  • Shim, Ji-Suk;Lee, Jeong-Yol;Choi, Yeon-Jo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.47-50
    • /
    • 2015
  • PURPOSE. This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat. MATERIALS AND METHODS. Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.2 Mpa; oxygen inhibition- applied an oxygen inhibitor around the repaired material,; heat treatment - performed heat treatment in a dry oven at $60^{\circ}C$, $100^{\circ}C$, or $140^{\circ}C$. The shear bond strength was measured with a universal testing machine, and the shear bond strength (MPa) was calculated from the peak load of failure. A comparison of the bond strength between the repaired specimens was conducted using one-way ANOVA and Tukey multiple comparison tests (${\alpha}$=.05). RESULTS. There were no statistically significant differences in the shear bond strength between the control group and the light curing, pressure, and oxygen inhibition groups. However, the heat treatment groups showed statistically higher bond strengths than the groups treated without heat, and the groups treated at a higher temperature resulted in higher bond strengths. Statistically significant differences were seen between groups after different degrees of heat treatment, except in groups heated at $100^{\circ}C$ and $140^{\circ}C$. CONCLUSION. Strong bonding can be achieved between a bis-acryl base and bis-acryl repair material after heat treatment.

Short-term Forecasting of Power Demand based on AREA (AREA 활용 전력수요 단기 예측)

  • Kwon, S.H.;Oh, H.S.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • It is critical to forecast the maximum daily and monthly demand for power with as little error as possible for our industry and national economy. In general, long-term forecasting of power demand has been studied from both the consumer's perspective and an econometrics model in the form of a generalized linear model with predictors. Time series techniques are used for short-term forecasting with no predictors as predictors must be predicted prior to forecasting response variables and containing estimation errors during this process is inevitable. In previous researches, seasonal exponential smoothing method, SARMA (Seasonal Auto Regressive Moving Average) with consideration to weekly pattern Neuron-Fuzzy model, SVR (Support Vector Regression) model with predictors explored through machine learning, and K-means clustering technique in the various approaches have been applied to short-term power supply forecasting. In this paper, SARMA and intervention model are fitted to forecast the maximum power load daily, weekly, and monthly by using the empirical data from 2011 through 2013. $ARMA(2,\;1,\;2)(1,\;1,\;1)_7$ and $ARMA(0,\;1,\;1)(1,\;1,\;0)_{12}$ are fitted respectively to the daily and monthly power demand, but the weekly power demand is not fitted by AREA because of unit root series. In our fitted intervention model, the factors of long holidays, summer and winter are significant in the form of indicator function. The SARMA with MAPE (Mean Absolute Percentage Error) of 2.45% and intervention model with MAPE of 2.44% are more efficient than the present seasonal exponential smoothing with MAPE of about 4%. Although the dynamic repression model with the predictors of humidity, temperature, and seasonal dummies was applied to foretaste the daily power demand, it lead to a high MAPE of 3.5% even though it has estimation error of predictors.

Analysis of a damaged industrial hall subjected to the effects of fire

  • Kmet, Stanislav;Tomko, Michal;Demjan, Ivo;Pesek, Ladislav;Priganc, Sergej
    • Structural Engineering and Mechanics
    • /
    • v.58 no.5
    • /
    • pp.757-781
    • /
    • 2016
  • The results of diagnostics and analysis of an industrial hall located on the premises of a thermal power plant severely damaged by fire are presented in the paper. The comprehensive failure-related diagnostics, non-destructive and destructive tests of steel and concrete materials, geodetic surveying of selected structural members, numerical modelling, static analysis and reliability assessment were focused on two basic goals: The determination of the current technical condition of the load bearing structure and the assessment of its post fire resistance as well as assessing the degree of damage and subsequent design of reconstruction measures and arrangements which would enable the safe and reliable use of the building. The current mechanical properties of the steel material obtained from the tests and measured geometric characteristics of the structural members with imperfections were employed in finite element models to study the post-fire behaviour of the structure. In order to compare the behaviour of the numerically modelled steel roof truss, subjected to the effects of fire, with the real post-fire response of the damaged structure theoretically obtained resistance, critical temperature and the time at which the structure no longer meets the required reliability criteria under its given loading are compared with real values. A very good agreement between the simulated results and real characteristics of the structure after the fire was observed.

IN VITRO EVALUATION OF FRACTURE RESISTANCE OF VARIOUS THICKNESS FIBER- REINFORCED COMPOSITE INLAY FPD

  • Yi Yang-Jin;Yoon Dong-Jin;Park Chan-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.762-771
    • /
    • 2003
  • Statement of problem. In dentistry, the minimally prepared inlay resin-bonded fixed partial denture (FPD) made of new ceromer / fiber-reinforced composite (FRC) was recently introduced. However, the appropriate dimensions for the long-term success and subsequent failure strength are still unknown. Purpose. The aim of this study was to investigate the most fracture-resistible thickness combination of the ceromer / FRC using a universal testing machine and an AE analyzer. Material and Methods. A metal jig considering the dimensions of premolars and molars was milled and 56-epoxy resin dies, which had a similar elastic modulus to that of dentin, were duplicated. According to manufacturer's instructions, the FRC beams with various thicknesses (2 to 4 mm) were constructed and veneered with the 1 or 2 mm-thick ceromers. The fabricated FPDs were luted with resin cement on the resin dies and stored at room temperature for 72 hours. AE (acoustic emission) sensors were attached to both ends, the specimens were subjected to a compressive load until fracture at a crosshead speed of 0.5 mm/min. The AE and failure loads were recorded and analyzed statistically. Results. The results showed that the failure strength of the ceromer/FRC inlay FPDs was affected by the total thickness of the connectors rather than the ceromer to FRC ratio or the depth of the pulpal wall. Fracture was initiated from the interface and propagated into the ceromer layer regardless of the change in the ceromer / FRC ratio. Conclusion. Within the limitations of this study, the failure loads showed significant differences only in the case of different connector thicknesses, and no significant differences were found between the same connector thickness groups. The application of AE analysis method in a fiber-reinforced inlay FPD can be used to evaluate the fracture behavior and to analyze the precise fracture point.