• 제목/요약/키워드: No load temperature

검색결과 241건 처리시간 0.028초

Flexural strengths of implant-supported zirconia based bridges in posterior regions

  • Rismanchian, Mansour;Shafiei, Soufia;Nourbakhshian, Farzaneh;Davoudi, Amin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.346-350
    • /
    • 2014
  • PURPOSE. Impact forces in implant supported FDP (fixed dental prosthesis) are higher than that of tooth supported FDPs and the compositions used in frameworks also has a paramount role for biomechanical reasons. The aim of this study was to evaluate the flexural strength of two different zirconia frameworks. MATERIALS AND METHODS. Two implant abutments with 3.8 mm and 4.5 mm platform were used as premolar and molar. They were mounted vertically in an acrylic resin block. A model with steel retainers and removable abutments was fabricated by milling machine; and 10 FDP frameworks were fabricated for each Biodenta and Cercon systems. All samples were thermo-cycled for 2000 times in $5-55^{\circ}C$ temperature and embedded in $37^{\circ}C$ artificial saliva for one week. The flexural test was done by a rod with 2 mm ending diameter which was applied to the multi-electromechanical machine. The force was inserted until observing fracture. The collected data were analyzed with SPSS software ver.15, using Weibull modulus and independent t-test with the level of significance at ${\alpha}=.05$. RESULTS. The mean load bearing capacity values were higher in Biodenta but with no significant differences (P>.05). The Biodenta frameworks showed higher load bearing capacity ($F_0=1700$) than Cercon frameworks ($F_0=1520$) but the reliability (m) was higher in Cercon (m=7.5). CONCLUSION. There was no significant difference between flexural strengths of both zirconia based framework systems; and both Biodenta and Cercon systems are capable to withstand biting force (even parafunctions) in posterior implant-supported bridges with no significant differences.

청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구 (A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage)

  • 이석건;고재군
    • 한국농공학회지
    • /
    • 제18권1호
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

A branch-switching procedure for analysing instability of steel structures subjected to fire

  • Morbioli, Andrea;Tondini, Nicola;Battini, Jean-Marc
    • Structural Engineering and Mechanics
    • /
    • 제67권6호
    • /
    • pp.629-641
    • /
    • 2018
  • The paper describes the development of a two-dimensional (2D) co-rotational nonlinear beam finite element that includes advanced path-following capabilities for detecting bifurcation instability in elasto-plasticity of steel elements subjected to fire without introducing imperfections. The advantage is twofold: i) no need to assume the magnitude of the imperfections and consequent reduction of the model complexity; ii) the presence of possible critical points is checked at each converged time step based on the actual load and stiffness distribution in the structure that is affected by the temperature field in the elements. In this way, the buckling modes at elevated temperature, that may be different from the ones at ambient temperature, can be properly taken into account. Moreover, an improved displacement predictor for estimating the displacement field allowed significant reduction of the computational cost. A co-rotational framework was exploited for describing the beam kinematic. In order to highlight the potential practical implications of the developed finite element, a parametric analysis was performed to investigate how the beam element compares both with the EN1993-1-2 buckling curve and with experimental tests on axially compressed steel members. Validation against experimental data and numerical outcomes obtained with commercial software is thoroughly described.

KSTAR TOKAMAK의 열차폐막 설계 (The Design of Thermal Shield for KSTAR TOKAMAK)

  • 김동락;노영미;허남일;조승연;육종설;안귀천;도철진;권면;이경수;윤병주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.45-47
    • /
    • 2001
  • The function of the thermal shield(TS) is to eliminate the thermal radiation from the room temperature side to the coil temperature(4.5K) region so as to reduce the thermal load on the He refrigerator. The TS is composed of multilayer insulation(MLI) which is coated very thin aluminum on the insulating material, cryopanel which is cooled by cold gaseous He, and supports which stand the cryopanel and MLI on the room temperature part. The thermal shield for the TF coils and PF coils has been located between the coils and vacuum vessel. The thermal shielding cryopanel is cooled under 80 K by a forced flow of helium gas using cooling pipes on the cryopanel.

  • PDF

대기온도, 증발기 누출, 엔진오일 및 엔진부하에 따른 LPG 차량의 연비실험에 관한 연구 (Experimental Study on Fuel Consumptions of LPG Vehicle Depending on the Atmospheric Temperature, Vaporizer Gas Leakage, Engine Oil and Engine Loads)

  • 김청균;이일권
    • 한국가스학회지
    • /
    • 제13권5호
    • /
    • pp.1-6
    • /
    • 2009
  • 본 논문에서는 LPG 차량의 연비효과에 미치는 대기온도, 증발기의 가스누출, 엔진오일의 점도, 엔진의 부하조건을 실험적으로 고찰하고자 한다. 연비에 대한 시험결과에 의하면, 엔진의 온도가 상승할수록 연비효과도 함께 점차 높아지고 있다. 대기온도가 $24.2^{\circ}C$일 때의 연비는 $1^{\circ}C$일 때보다 13.6% 정도 높게 나타난 것을 알 수 있다. LP가스 누출이 없는 증발기의 연비는 가스누출이 있는 경우에 비해 5.3%나 좋아지는 것으로 확인되었다. 반면에 엔진오일을 새로 교환한 경우의 연비는 9,500km를 주행한 오일에 비해 1.1% 정도 향상된 것으로 나타났으며, 이것은 대기온도나 증발기의 누설조건에 비해 상대적으로 낮은 영향을 미치는 것으로 관찰되었다. 연비에 더 많은 영향을 미치는 요소는 급제동, 급출발, 급가속과 같은 운전조건으로 판단된다. 연비시험 결과에 의하면, 정상출발은 급출발에 비해 32.3%나 연비가 향상되었고, 급가속은 급출발보다 10.8%나 우수한 연비조건을 보여주고 있다. 또한, 급제동은 급출발보다 18.3%나 우수한 연비상태를 나타내고 있다. 결국 비정상적인 주행조건은 정상적인 운전패턴에 비해 연비가 나쁜 것으로 나타났으므로, 연비를 높이기 위해서는 차량의 주행조건을 정상상태로 유지하는 것이 대단히 중요함을 알 수 있다.

  • PDF

레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석 (Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply)

  • 유지호;조종현;정민길;박성진;강광희
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

경량형 옥상녹화에 따른 열부하 저감 잠재성 연구 (Reduction Potential for Thermal Load by Extensive Green Roofs)

  • 김연미;남미아;장대희;김현수;김현옥
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.67-77
    • /
    • 2013
  • Based on the increasing demand for a solution to reduce thermal load, extensive green roofs have great opportunity for application to existing roofs due to their light-weight and easy maintenance. The present study delivers data regarding thermal behavior and heat reduction potential in relation to vegetation coverage between green roof types. 1) In the hottest hour in a day, green roofs showed considerable potential to mitigate heat load in roof environments, which can be up to $10^{\circ}C$ difference. 2) Compared to conventional cement roofs, the extensive green roofs only have a slight potential to cool the air over green roofs. By statistical analysis of linear regression, green coverage has little to do with the reduction of air temperature; the cooling effect was proven only in nighttime. 3) Green roofs act as an insulating roof membrane, the inner substrate of green roofs remained cooler than cement roof surfaces in the daytime, but in the nighttime the green roofs generally were warmer than the cement roof surfaces. 4) The variable of vegetation coverage resulted in no significant difference in thermal behavior in the air, but had the greatest effect in keeping the substrate cool in the daytime. The high vegetation coverage also hindered the rapid cooling of the substrate in the nighttime, and therefore was warmer than other measured temperatures. In order to draw a clear conclusion to combat urban heat island effect with extensive green roofs, the experiment needs to be applied on a larger scale.

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

Evaluation for Impacts of Nitrogen Source to Groundwater Quality in Livestock Farming Area

  • Lee, Gyeong-Mi;Park, Sunhwa;Kim, Ki-In;Jeon, Sang-Ho;Song, Dahee;Kim, Deok-hyun;Kim, Tae-Seung;Yun, Seong-Taek;Chung, Hyen Mi;Kim, Hyun-Koo
    • 한국토양비료학회지
    • /
    • 제50권5호
    • /
    • pp.345-356
    • /
    • 2017
  • We investigated 52 livestock farming complexes in Gyeong-Gi and Incheon provinces based on low, medium, and high livestock density and groundwater quality. The objective of this study was to evaluate a relationship between nitrate N concentration in groundwater and animal factors, such as livestock density and animal species. 2,200 groundwater samples for 3 years from 2012 to 2014 at Gyeong-Gi and Incheon provinces were collected and analyzed for pH, EC, DO, ORP, temperature, major anions and cations, such as $NO_3-N$, ${HCO_3}^-$, ${PO_4}^-$, ${SO_4}^{2-}$, $Cl^-$, $NH_4-N$, $K^+$, $Na^+$, $Ca^{2+}$, $Mg^{2+}$, T-N, and TOC. Average concentration of total N for generated load density was $23,973g\;day^{-1}\;km^{-2}$ for cattle, $51,551g\;day^{-1}\;km^{-2}$ for pig, and $52,100g\;day^{-1}\;km^{-2}$ for poultry. For animal feeding species, average ratio for generated load over discharge load was 16.1% for cattle, 7.8% for pig, and 7.1% for poultry. Therefore, cattle feeding region is highly vulnerable for water pollution compared to pig and poultry feeding areas. The concentrations of chloride, nitrate, and total N in the groundwater samples were higher at high animal farming regions than other regions. The average concentration of nitrate, and chloride in groundwater samples was $5.0mg\;L^{-1}$, $16.6mg\;L^{-1}$ for low livestock density, $6.9mg\;L^{-1}$, $17.7mg\;L^{-1}$ for medium livestock density and $7.6mg\;L^{-1}$, $22.7mg\;L^{-1}$ for high livestock density and total nitrogen (T-N) was $7.7mg\;L^{-1}$ for low livestock density, $9.4mg\;L^{-1}$ for medium livestock density, $10.7mg\;L^{-1}$ for high livestock density. In conclusion, based on this research, for managing groundwater quality near livestock farming regions, $Ca-(Cl+NO_3)$ group from the Piper diagram is more efficient than using 19 factors for water quality standard.

치과 도재용착용 Ni-Cr 합금의 열처리에 따른 결합력 연구 (Study on Shear Bond Strength of Ni-Cr Alloy for Porcelain Fused to Metal Crown at the Temperature of Degassing)

  • 주규지;신재우;조홍규
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.69-77
    • /
    • 2016
  • Purpose: This study was to evaluate the shear bond strength of ceramic fused to Ni-Cr alloy(Alophaloy) by heat treatment. Methods: The specimens were divided into 5 groups according to heat treatment conditions prior to porcelain application. Eighteen specimens from each group were subjected to the shear load a universal testing machine using a 0.1mm/min cross-head speed and two specimens from each group were observed with SEM and EDX line profile. Results: The observation of the oxide film on the metal surface by SEM photograph showed a coarsening with an increasing degassing hold time. The diffusion of metal oxide was observed farther from the opaque layer in the heat treated specimen than no heat treated specimen. The shear bond strength measured highest to A5(55.23MPa) in the 10min holding group and measured lowest from A1(24.38MPa) in the no heat treated group, and there was a significant difference(p<0.05). Conclusion: The shear bond strength of Ni-Cr alloy improved in the heat treatment compared to the no heat treatment specimen.