• Title/Summary/Keyword: No Fault Found

Search Result 40, Processing Time 0.028 seconds

Native Hawaiian Collection Systems in Lava Tubes(Caves) and Fault Cracks: Puna - Ka'u Districts, Hawaii

  • Martin, James F.
    • Journal of the speleological society of Korea
    • /
    • no.4
    • /
    • pp.41-50
    • /
    • 1996
  • The coastal plains of the Puna and Ka' u Districts of the island of Hawaii are a contradiction to the popular view that the island of Hawaii is a tropical rain forest or a vegetated landscape with abundant water sour This section of the island lies in the rain shadow of Mauna Loa a Kilauea Volcanoes and receives less than 30 inches of annual precipita When rain does come. it is in the form of sudden down pours. givi residents of the area little time to collect and conserve water. Due to porous nature of the rock. there is no standing surface water. In spite of these harsh climatic conditions. archeological evidence indic that an extensive agriculture complex existed not only along the coast. into the most remote parts of what is called the Ka'u Desert. Pass through these agricultural areas are historic and pre - historic t systems. These trail systems apparently played a significant suppor role for exchange between the ahupua's (classic land divisions of Haw and the geopolitical districts. The question arises as to how could vast agricultural complexes a heavy foot travel over miles of arid land exist without dependable wa sources\ulcorner While planting - pits and mounds were designed to make most efficient use of available water and conserve moisture(Carter 19 9). people involved in planting also needed potable water for surv Most publications and research papers dealing with the early population this area make only oblique reference to springs and wells which t populations depended upon. The Federal Cave Resource Protection Act(1988) has served as imprtus for the National Park Service to look closer at the lava tu caves and fault cracks within Hawaii Volcanoes National Park. P visitors to these underground areas found large volumes of standing wa in fault cracks. and abundant drip areas with the lava tubes. Re observes noted that in most cases. where the cracks and caves we located in the arid sections of the park. there has been extens modifiacation or utilization of these water sources by the early Hawaii and others. The variety of western containers used for collection indica that these water sources were used during historic times. William E described similar water sources in his narrative of his trip around island in 1823(Eills 1979), This report is directed at documenting recent observations and a stimulating further research into early Hawaiian water collection syst It also explores the implications that power and political influence of e chiefs in the arid portions of Hawaii could have been linked to the con of the water resources.

  • PDF

Improvement of Circuit-Time Product through Analysis of Operating Time of Earth Leakage Circuit-Breakers (누전차단기의 트립 동작시간 분석을 통한 전류·시간적(積) 개선)

  • Kim, Ju-Chul;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.44-49
    • /
    • 2012
  • The earth leakage circuit-breakers installed to protect the human body against electrical shock have conventionally had a sensitivity current of 30 mA and an operating time of 30 ms or less. No reviews are found, however, on the operating time of the current conducting through the human body due to the electrical shock or ground fault. This paper measures the trip-operating time against the earth leakage under the condition of increased current as well as under the condition of rated sensitivity current of the earth leakage circuit-breakers. Further measurement with a prototype model showed an improved operating time of 16 ms or less under the condition of rated sensitivity current. It is expected that development of circuit-breakers with higher safety is possible if the performance of the electronic circuit can be improved.

Novel Method of ACO and Its Application to Rotor Position Estimation in a SRM under Normal and Faulty Conditions

  • Torkaman, Hossein;Afjei, Ebrahim;Babaee, Hossein;Yadegari, Peyman
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.856-863
    • /
    • 2011
  • In this paper a novel method of the Ant Colony Optimization algorithm for rotor position estimation in Switched Reluctance Motors is presented. The data provided by the initial assumptions is one of the important aspects used to solve the problems relative to an Ant Colony algorithm. Considering the nature of a real ant colony, it was found that the ants have no primary data for deducing which is the shortest path in their initial iteration. They also do not have the ability to see the food sources at a distance. According to this point of view, a novel method is presented in which the rotor pole position relative to the corresponding stator pole in a switched reluctance motor is estimated with high accuracy using the active and inactive phase parameters. This new method gives acceptable results such as a desirable convergence together with an optimized and stable response. To the best knowledge of the authors, such an analysis has not been carried out previously.

Structural damage detection using decentralized controller design method

  • Chen, Bilei;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.779-794
    • /
    • 2008
  • Observer-based fault detection and isolation (FDI) filter design method is a model-based method. By carefully choosing the observer gain, the residual outputs can be projected onto different independent subspaces. Each subspace corresponds to the monitored structural element so that the projected residual will be nonzero when the associated structural element is damaged and zero when there is no damage. The key point of detection filter design is how to find an appropriate observer gain. This problem can be interpreted in a geometric framework and is found to be equivalent to the problem of finding a decentralized static output feedback gain. But, it is still a challenging task to find the decentralized controller by either analytical or numerical methods because its solution set is, generally, non-convex. In this paper, the concept of detection filter and iterative LMI technique for decentralized controller design are combined to develop an algorithm to compute the observer gain. It can be used to monitor structural element state: healthy or damaged. The simulation results show that the developed method can successfully identify structural damages.

A Study on Software Fault Analysis and Management Method using Defect Tracking System (결함 추적 시스템에 의한 소프트웨어 결함 분석 및 관리기법 연구)

  • Joon, Moon-Young;Yul, Rhew-Sung
    • The KIPS Transactions:PartD
    • /
    • v.15D no.3
    • /
    • pp.321-326
    • /
    • 2008
  • The software defects that are not found in the course of a project frequently appear during the conduct of the maintenance procedure after the complete development of the software. As the frequency of surfacing of defects during the maintenance procedure increases, the cost likewise increases, and the quality and customer reliability decreases. The defect rate will go down only if cause analysis and process improvement are constantly performed. This study embodies the defect tracking system (DTS) by considering the Pareto principle: that most defects are repetitions of defects that have previously occurred. Based on the records of previously occurring defects found during the conduct of a maintenance procedure, DTS tracks the causes of the software defects and provides the developer, operator, and maintenance engineer with the basic data for the improvement of the software concerned so that the defect will no longer be manifested or repeated. The basic function of DTS is to analyze the defect type, provide the measurement index for it, and aggregate the program defect type. Doing these will pave the way for the full correction of all the defects of a software as it will enable the defect correction team to check the measured defect type. When DTS was applied in the software configuration management system of the W company, around 65% of all its software defects were corrected.

The development of deformation microstructures and textures in high Mn steels (고Mn강의 소성에 따른 미세조직및 Texture 변화에 관한연구)

  • Kim, Taek-Nam;Kim, Jong-Ok
    • The Journal of Natural Sciences
    • /
    • v.7
    • /
    • pp.83-90
    • /
    • 1995
  • The microstructural and textural development during rolling is compared in two Hadifield's steels (high Mn steel), one having low carbon content (0.65 wt.%) and the other high carbon (1.35 wt.%).In low carbon Hadfield's steel (LCHS) mixed microstructures are formed which contain intrinsic stacking faults, deformation twins, and brass type shear bands. The deformation twins are thought to be formed by the stacking of intrinsic stacking faults. The similar development to 70-30 brass texture is observed in early deformation. However the abnormal texture is developed after 40 % deformation, which is thought to be due to the martensite phase transformation. In high carbon Hadfield's steel (HCHS) mixed substructures of dislocation tangles, deformation twins, and shear bands (both copper and brass type) are found to develop. The texture development is similar to that of 70-30 brass. This is consistant with no carbon segregation and no martensitic phase transformation in HCHS. In spite of the difference of substructure and texture development during rolling in two steels, the difference in stacking fault energy is measured to be small ($2 mJm^-2$). The carbon segregation is only occurred in LCHS. Thus it is thought that the carbon segregation influence the microstructure and texture development during rolling. This is related with martensite phase transformation in LCHS.

  • PDF

Characteristics of South Korea's Geothermal Water in Relation to Its Geological and Geochemical Feature

  • Lee, Chung-Mo;Hamm, Se-Yeong;Lee, Cholwoo;Choi, Sung-Ja;Chung, Sang Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.2
    • /
    • pp.25-37
    • /
    • 2014
  • The volcanic type of geothermal water is linked intimately to active or potentially active volcanoes and takes place near the plate boundaries. In contrast to the volcanic type, the geothermal water in Korea has a non-volcanic origin. Korea's geothermal water is classified into the residual magma (RM) type and deep groundwater (DG) type according to the criterion of $35^{\circ}C$. This study reviewed the relationship between the physical and chemical features of the 281 geothermal water sources in South Korea in terms of the specific capacity, water temperature, and chemical compositions of two different basements (igneous rock and metamorphic rock) as well as the geological structures. According to the spatial relationship between the geothermal holes and geological faults, the length of the major fault is considered a key parameter determining the movement to a deeper place and the temperature of geothermal water. A negligible relationship between the specific capacity (Q/s) and temperature was found for both the RM type and DG type with the greater specific capacities of the RM- and DG-igneous types than the RM- and DG-metamorphic types. No relationship was observed between Q/s and the chemical constituents ($K^+$, $Na^+$, $Ca^{2+}$, $Mg^{2+}$, $Zn^{2+}$, $Cl^-$, $SO_4{^{2-}}$, $HCO_3{^-}$, and $SiO_2$) in the DG-igneous and DG-metamorphic types. Furthermore, weak relationship between temperature and chemical constituents was found for both the RM type and DG type.

Study on Factors Affecting Nurses' Experience of Non-Reporting Incidents (병원 간호사의 사건보고 불이행 경험여부에 영향을 미치는 요인)

  • Kim, Ki-Kyong;Song, Mal-Soon;Rhee, Kae-Sook;Hur, Hea-Kung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.3
    • /
    • pp.454-463
    • /
    • 2006
  • Purpose: This study was designed to identify the factors affecting the nurses' experience of non-reporting adverse incidents in hospital. Methods: This study is a cross-sectional, descriptive survey design and nonrandom, convenience sampling. Study subjects were 392 clinical nurses, who have agreed to be the subject of this research. The measuring instrument of attitudes toward incident reporting was developed by the authors. The questionnaire which consisted of 17 items about worry about appraisal, the belief in improvement, the intention of reporting, and knowledge was measured by 5-point Likert-type scale. The estimate of internal consistency was alpha =.84. Analysis of data was done with use of mean, t-test, ANOVA, logistic regression with SPSS program. Results: Clinical nurses had experience of reporting incident (51.3%), non-reporting incident (76.5%). Statistically, significant differences were found between experiences group and non experience group in intention on reporting, belief on improvement, and worry about appraisal. Logistic regression analysis showed that the significant predictors were caused by report no-fault cases, belief on improvement, worry about appraisal. Conclusion: The result also indicated that, to improve the incident reporting and risk management, it might be necessary to give a belief that it results on improvement and remove concern about punishment through construction of no-blame system.

  • PDF

Technical Review on Risk Assessment Methodology for Carbon Marine Geological Storage Systems (이산화탄소 해양 지중저장 시스템에서의 누출 위해성 평가방법에 관한 기술적 검토)

  • Hwang, Jin-Hwan;Kang, Seong-Gil;Park, Young-Gyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Carbon Capture and Storage (CCS) technology mitigates the emission amount of carbon dioxide into the atmosphere and can reduce green house effect which causes the climate change. Deep saline aquifer or obsolete oil/gas storage etc. in the marine geological structure are considered as the candidates for the storage. The injection and storage relating technology have been interested in the global society, however the adverse effect caused by leakage from the system failure. Even the safety level of the CCS is very high and there is almost no possibility to leak but, still the risk to marine ecosystem of the high concentrated carbon dioxide exposure is not verified. The present study introduces the system and environmental risk assessment methods. The feature, event and process approach can be a good starting point and we found the some possibility from the fault tree analysis for evaluation. From the FEP analysis, we drove the possible scenario which we need to concentrate on the construction and operation stages.

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.