• Title/Summary/Keyword: No Failure Test Time

Search Result 101, Processing Time 0.031 seconds

Flexural bearing capacity and stiffness research on CFRP sheet strengthened existing reinforced concrete poles with corroded connectors

  • Chen, Zongping;Song, Chunmei;Li, Shengxin;Zhou, Ji
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.29-42
    • /
    • 2022
  • In mountainous areas of China, concrete poles with connectors are widely employed in power transmission due to its convenience of manufacture and transportation. The bearing capacity of the poles must have degenerated over time, and most of the steel connectors have been corroded. Carbon fiber reinforced polymer (CFRP) offers a durable, light-weight alternative in strengthening those poles that have served for many years. In this paper, the bearing capacity and failure mechanism of CFRP sheet strengthened existing reinforced concrete poles with corrosion steel connectors were investigated. Four poles were selected to conduct flexural capacity test. Two poles were strengthened by single-layer longitudinal CFRP sheet, one pole was strengthened by double-layer longitudinal CFRP sheets and the last specimen was not strengthened. Results indicate that the failure is mainly bond failure between concrete and the external CFRP sheet, and the specimens fail in a brittle pattern. The cross-sectional strains of specimens approximately follow the plane section assumption in the early stage of loading, but the strain in the tensile zone no longer conforms to this assumption when the load approaches the failure load. Also, bearing capacity and stiffness of the strengthened specimens are much larger than those without CFRP sheet. The bearing capacity, initial stiffness and elastic-plastic stiffness of specimen strengthened by double-layer CFRP are larger than those strengthened by single-layer CFRP. Weighting the cost-effective effect, it is more economical and reasonable to strengthen with single-layer CFRP sheet. The results can provide a reference to the same type of poles for strengthening design.

A Study on the Assessment of Residual Life Span for Old Type Signalling Equipment (노후신호장치 잔존수명 평가에 관한 연구)

  • Shin, Ducko-Shin;Lee, Jae-Ho;Shin, Kyung-Ho;Kim, Yong-Kyu;Kang, Min-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.535-541
    • /
    • 2009
  • The reliability of control system composed of electronic parts has been studied by DoD since 1960, and has been undertaken mainly by Europe for railways. Especially in Korea, a study on reliability of signalling equipment has been taken since 2000, requiring reliability test for effective maintenance of old type signalling equipment which no longer has information on its past reliability. This study evaluates the reliability test in units of parts for old type signalling equipment; for instance, failure rate in units of parts, or failure data during operation; which was utilized without its consistent reliability monitoring and analysis data for over 20 years. Also, reliability change at this point in time has been estimated by using residual life span function, and a model which can evaluate the possibility of extended operation through stress acceleration test has been developed. This model will be utilized to establish future maintenance policy for train operating company's operation on old type signalling equipment.

Experimental study of the behavior of beam-column connections with expanded beam flanges

  • Ma, Hongwei;Wang, Jiwei;Lui, Eric M.;Wan, Zeqing;Wang, Kun
    • Steel and Composite Structures
    • /
    • v.31 no.3
    • /
    • pp.319-327
    • /
    • 2019
  • This paper describes an experimental study of steel beam-column connections with or without expanded beam flanges with different geometries. The objectives of this study are to elucidate the cyclic behavior of these connections, identify the location of the plastic hinge zone, and provide useful test data for future numerical simulations. Five connection specimens are designed and tested under cyclic load. The test setup consists of a beam and a column connected together by a connection with or without expanded beam flanges. A constant axial force is applied to the column and a time varying point load is applied to the free end of the beam, inducing shear and moment in the connection. Because the only effect to be studied in the present work is the expanded beam flange, the sizes of the beam and column as well as the magnitude of the axial force in the column are kept constant. However, the length, width and shape of the expanded beam flanges are varied. The responses of these connections in terms of their hysteretic behavior, failure modes, stiffness degradation and strain variations are experimentally obtained and discussed. The test results show that while the influence of the expanded beam flanges on hysteretic behavior, stiffness degradation and energy dissipation capacity of the connection is relatively minor, the size of the expanded beam flanges does affect the location of the plastic hinge zone and strain variations in these beam-column joints. Furthermore, in terms of ductility, moment and rotational capacities, all five connections behave well. No weld fracture or premature failure occurs before the formation of a plastic hinge in the beam.

PULPAL ANESTHETIC EFFECT OF INFERIOR ALVEOLAR NERVE BLOCK AND GOW-GATES TECHNIQUE (하악공 전달마취법과 Gow-Gates법의 치수마취 효과)

  • Ahn, Sik-Hwan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.278-290
    • /
    • 1997
  • The purposes of this study were to evaluate and compare the pulpal anesthesia induced by an inferior alveolar nerve block and that by Gow-Gates technique, and to investigate the relationship between pulpal anesthesia and intraoral soft tissue responses. After one side of mandibule was anesthetized with inferior alveolar nerve block or Gow-Gates technique using 2 % lidocaine with 1 : 100,000 epinephrine in 19 volunteers of ages between 24 and 29 (16 males and 3 females, average age 25.9 yrs.), electric pulp tests were done on the canine teeth of the anesthetized side and contralateral one before, at 1 min, continued at every 5 minutes until 60 min, and every 10 minutes until 100 min after completion of local anesthetic injection. Degree of pulpal anesthesia was classified as anesthetic failure, possible anesthesia and complete anesthesia by the criteria based on the thresholds to electric pulp test of contralateral canine and the currents of the electric pulp tester. Subjective signs on the lower lip and tongue were checked and prick-pin tests were done on the buccal gingiva of the first molar, buccal and lingual gingiva of the canine tooth at 5, 10 and 20 min after the completion of anesthetic injection. Thresholds to electric pulp test, degree of pulpal anesthesia and relationship between the pulpal anesthesia and soft tissue responses were analyzed with SPSS, paired t-test, Wilcoxon matched-pairs signed-ranks test and correlation analysis. The results were as follows : No significant differences were found in the peak thresholds to electric pulp test, in the induction time to it and in the depth of pulpal anesthesia between inferior alveolar nerve block and Gow-Gates technique (p>0.05). There was no significant relationship between pulpal anesthesia and soft tissue responses in both inferior nerve block and Gow-Gates technique.

  • PDF

Effect of Shield Line on Noise Margin and Refresh Time of Planar DRAM Cell for Embedded Application

  • Lee, Jung-Hwan;Jeon, Seong-Do;Chang, Sung-Keun
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.583-588
    • /
    • 2004
  • In this paper we investigate the effect of a shield metal line inserted between adjacent bit lines on the refresh time and noise margin in a planar DRAM cell. The DRAM cell consists of an access transistor, which is biased to 2.5V during operation, and an NMOS capacitor having the capacitance of 10fF per unit cell and a cell size of $3.63{\mu}m^2$. We designed a 1Mb DRAM with an open bit-line structure. It appears that the refresh time is increased from 4.5 ms to 12 ms when the shield metal line is inserted. Also, it appears that no failure occurs when $V_{cc}$ is increased from 2.2 V to 3 V during a bump up test, while it fails at 2.8 V without a shield metal line. Raphael simulation reveals that the coupling noise between adjacent bit lines is reduced to 1/24 when a shield metal line is inserted, while total capacitance per bit line is increased only by 10%.

  • PDF

The Effects of Foreign Direct Investment and Economic Absorptive Capabilities on the Economic Growth of the Lao People's Democratic Republic

  • NANTHARATH, Phouthakannha;KANG, Eungoo
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.3
    • /
    • pp.151-162
    • /
    • 2019
  • The paper examines the effects of Foreign Direct Investment (FDI) on the economic growth of Lao People's Democratic Republic (Lao PDR) between 1993 and 2015. The investigation is based on the influence of growth and economic absorptive capability determinants such as human capital, trade openness, and institutional quality. The methodological analysis uses a multivariate framework accounting capital stock, labor stock, FDI, human capital, trade openness, and institutional quality in regression of the Vector Autoregressive model. Augmented Dickey-Fuller unit root test, Johansen Cointegration test, and Granger Causality test were applied as parts of the econometric time-series analysis approach. The empirical results demonstrate the positive effects of FDI and trade openness, and the negative effects of human capital and institutional quality on the economic growth of the Lao PDR over the 1993 to 2015 period. The findings confirm that trade openness complemented by a sufficient level of infrastructure, education, quality institutions, and transparency significantly influence economic growth and attract more FDI. Research results lend credence to the need for the Lao PDR's government to focus on improving its economic absorptive capability and economic competitiveness regionally and globally by improving wealth and resource management strategies, as failure to take this course of action could lead to the Dutch Disease effects.

Validation study of integrated intubation tube with stylet(IITS) in tracheal intubation (기관내삽관에서 속심일체형 삽관튜브 용이성에 관한 연구)

  • Yun, Hyeong-Wan;Lee, Jae-Min;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.3
    • /
    • pp.111-121
    • /
    • 2019
  • Purpose: Difficult organs or locations or inadequate tube intubations can cause complications. There are some cases in which the tube location changes or the tube is removed due to processing inside the organ while installing the stylet or rapid stylet removal. Thus, this study aimed to evaluate and develop an integrated intubation tube with stylet (IITS) for easier intubation of organs in emergency cases and reduce complications caused by the stylet. Methods: This study used a "Laerdal Airway Management Trainer". For stylet intubation, procedure No. 14 of the national practical test protocol was followed, but the removal step was omitted. In this study, each emergency case was intubated with an IITS, in which the stylet was not inserted or removed separately even though it has the function of an organ intubation stylet. Results: The existing classic ET intubation method had a success rate of 100% and had an average intubation time of 21.75 seconds, The developed IITS method was also successful in all cases and had an average intubation time of 15.78 seconds. Conclusion: Application of an IITS is expected to reduce intubation time and decrease inappropriate depth and intubation failure due to stylet removal, therefore improving the efficiency of airway maintenance.

The Effect of Variation of Assembly Time on Glue Bond Strength (집결시간(集結時間)이 합판접착강도(合板接着强度)에 미치는 영향(影響))

  • Shim, Chong-Supp
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.118-131
    • /
    • 1982
  • 1. In order to investigate the effect of variation of assembly time on glue bond strength, and to determine the optimum range of assembly time with given glue, this experiment was made at the suggestion of the Wood Technology Laboratory, School of Forestry, Yale University. 2. For this investigation, three-ply-plywoods with 1/22 inch, birch veneer, phenolic resin, and soybean glue were made at the following variation of assembly time, that is, 1, 5, 10, 25, 35, 50, and 70 minutes, under both open and closed assembly manners, and the shear strength test at dry and wet were adoptted. 3. The shear strength and wood failure of each plywood panel constructed at the given assembly time have been illustrated in Tables 1, 2, 3 and 4. It has shown that there is a remarkable tendency, for increasing assembly time to give lower shear strength and wood failure throughout almost all cases. The effective range of assembly time of tested glues in this investigation for both open and closed assembly are summarized in the Table 7. Thus, allowable assembly time for Phenolic resin may be up to 10 minutes under open assembly and up to 50 minutes under closed assembly. For soybean glue, the permissible assembly time may be up to 5 minutes under open assembly and up to 15 minutes under closed assembly. The allowable assembly time for open assembly with the same glue is reduced by approximately one third or more than one third as compared with closed assembly time. This might mean that the closed asembly time for these glues is more practical than the open assembly.

  • PDF

Application of the New Surgical Technique for Orthotopic Heart Transplantation in Dogs (잡견에 있어서 새로운 심장수술기법의 적용)

  • 원태희;한재진;김기봉;노준량
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.207-211
    • /
    • 2000
  • Backgroud: Conventional cardiac transplantation with each atrial anastomosis designed by Shumway and associates has been used widely in cardiac transplantation because of its simplicity and efficiency. There have been many reports about the postoperative atrioventricular value regurgitation resulting from the alteration in atrial geometry after cardiac transplantation by Shumway's technique. New surgical technique of direct anastomosis of superior vena cava, inferior vena cava, right pulmonary vein and left pulmonary vein was introduced to overcome the those problems. We performed this study to test the feasibility of this new surgical technique prior to application to clinical practice. Material and Method: Conventional cardiac transplantation was performed on 12 mongrel dogs(Group I) and cardiac transplantation with new surgical mthod of direct anastomosis of SVC, IVC, left and right pulmonary veins was performed on 11 mongrel dogs(Group II). After weaning from cardiopulmonary bypass, we compared the postoperative rhythm, hemodynamic data, and echocardiographic findings between two groups. Result : The cardiopulmonary bypass time and graft ischemic time were 119.0$\pm$4.4 minutes, 162.0$\pm$4.5 minutes respectively in group I, and 140.0$\pm$7.1 minutes, 180.5$\pm$5.4 minutes respectively in group II. The cardiopulmonary time and graft ischemic time in group II were longer than those of group I (p<0.05). There were 3 cases of failure to weaning from cardipulmonary bypass onein group I and two in group II, and this difference was not significant statistically. Sinus rhythm was regained postoperatively in 58% (group I) and 82%(group II), without statistical significant between 2 groups. Postoperative echolcardiography showed 2 cases of tricuspid value regurgitation and 1 case of mitral regurgitation in group I, and no regurgitation of atrioventricular value in group II. Conclusion: Although these was no statistically significant difference between 2 groups, there was tendency of less arrhythmia and less atrioventricular valvular regurgitation in group II. We suggested that the new surgical technique could be a useful strategy in heart transplantation, especially in the case of size mismatching between donor and recipient.

  • PDF

Preparation and Dissolution Characteristics of Sustained Release Pellets Containing Isosorbide Dinitrate (질산 이소소르비드가 함유된 서방형 펠렛의 제조 및 용출 특성)

  • Lee, Gye-Won;Kim, Hak-Hyung;Ryu, Sung-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.381-385
    • /
    • 2008
  • Isosorbide dinitrate is an oral assiatant therapy agent of angina pectoris, myocardial infarction and congestive heart failure. The objective of this study was to formulate sustained release containing isosorbide dinitrate and assess their formulation variables. Pellets were prepared by fluid bed process and consist of drug layer and membrane layer. The pellets were coated with ethylcellulose along with $5{\sim}15%$ of plasticizer such as triacetin and diethyl butylrate. In vitro evaluation study was performed by comparative dissolution test between test and reference isosorbide dinitrate preparation. We could prepare sustained pellets of isosorbide dinitrate by fluid bed process which were reduced process time and had high content. The pellet coated with 1% ethylcellulose and triacetin(l5%) had a similar dissolution behavior compare to reference isosorbide dinitrate preparation controlling initial dissolution and those of dissolution at 30 min were 17.25 and 17.09%, respectively. Difference factor and similarity factor were $0{\sim}15$ and $50{\sim}100$ and there was no significant difference in bioequivalence between formulations. It might be concluded that our sustained release pellet of isosorbide dinitrate could be an alternatively delivery system to reference drug preparation.