• Title/Summary/Keyword: Nickel-Titanium

Search Result 214, Processing Time 0.037 seconds

Generation Rate and Content Variation of Manganese in Stainless Steel Welding (스테인레스 강 용접중 발생하는 망간의 발생량 및 함량변화에 관한 연구)

  • Yoon, Chung Sik;Kim, Jeong Han
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.254-263
    • /
    • 2006
  • Manganese has a role as both toxic and essential in humans. Manganese is also an essential component in the welding because it increases the hardness and strength, prevents steel from cracking of welding part and acts as a deoxidizing agent to form a stable weld. In this study, manganese generation rate and its content was determined in flux cored arc welding on stainless steel. Domestic two products and foreign four products of flux cored wires were tested in the well designed fume generation chamber as a function of input power. Welding fume was measured by gravimetric method and metal manganese was determined by inductively coupled plasma-atomic emission spectrophotometer. The outer shell of the flux cored wire tube and inner flux were analyzed by scanning electron microscopy to determine their metal compositions. Manganese generation rate($FGR_{mn}$) was increased as the input power increased. It was 16.3 mg/min at the low input power, 38.1 mg/min at the optimal input power, and up to 55.4 mg/min at the high input power. This means that $FGR_{mn}$ is increased at the work place if welder raise the current and/or voltage for the high productivity. The slope coefficient of $FGR_{mn}$ was smaller than that of the generation rate of total fume(FGR). Also, the correlation coefficient of $FGR_{mn}$ was 0.65 whereas that of FGR is 0.91. $FGR_{mn}$ was equal or higher in the domestic products than that of the foreign products although FGR was similar. From the electron microscopic analytical data, we concluded that outer shell of the wire was composed mainly of iron, chromium, nickel and less than 1.2 % of manganese. There are many metal ingredients such as iron, silica, manganese, zirconium, titanium, nickel, potassium, and aluminum in the inner flux but they were not homogeneous. It was found that both $FGR_{mn}$ and content of manganese was higher and more varied in domestic flux cored wires than those of foreign products. To reduce worker exposure to fumes and hazardous component at the source, further research is needed to develop new welding filler materials that improve the quality of flux cored wire in respect to these points. Welder should keep in mind that the FGR, $FGR_{mn}$ and probably the generation rate of other hazardous metals were increased as the input power increase for the high productivity.

UHV Materials (초고진공계재료)

  • 박동수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

A STUDY OF WORKING EFFICIENCY AND FILE DEFORMATION OF GT ROTARY FILE IN CURVED CANALS (GT rotary file을 이용한 만곡 근관형성시 작업 효율 및 file 변형 발생에 관한 연구)

  • 신주희;백승호;배광식;임성삼;윤수한;김병현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.418-435
    • /
    • 2001
  • Root canal preparation process is of utmost importance in successful treatment of root canal. Also, one of the most important purpose of the root canal preparation is to enlarge the root canal three dimensionally without changing the curvature of the root canal However as the curvature of the root canal increases, there are many difficulties involved in formation of optimum root canal. Therefore in order to solve the above mentioned problems, new developments in methods of root canal preparation and equipments for such purposes were made. Recently, vigorous studies about newly introduced engine-driven nickel-ti-tanium rotary file are conducted. As shown in research results to dates, it is well established that the use of nickel-titanium file is better suited for curved root canal than stainless steel file in maintaining the curvature or root canal and reducing the deformation of root canal. However it is also acknowledged that there are a few discrepancies in research results according to protocol, due to failure to remove variables in experiments. In addition, although it is recommended by the manufacturer that the GT rotary file should maintain a low rotational speed of 150~350rpm and 'light pressure' as light as not to break the lead of a pencil, academic studies about the vertical force which is not yet standardized are not sufficiently explored. Therefore, this research devised and utilized a special research equipment to standardize the appropriate range of vertical force for GT rotary file through experiments by breaking of the lead of a pencil as expressed by the manufacturer and to accurately measure factors involved through repeating and recreating the environment of root canal preparation. Forming nine experimental groups by varying the vertical forces (150g. 220g, 300g) and rpm (150rpm, 250rpm, 350rpm), the effects of changing vertical forces and rpm on working efficiency were measured in terms of time expended in root canal preparation by crown-down method using a transparent resin block with 35 degree curvature and GT rotary file (z-test). The following research using this special research equipment that involved nine experimental groups and varying the vertical force for root canal preparation from 300g which is within the normal vertical force range to 700g and 1000g which fall outside the normal rpm range. The results were as follows : 1. Analysis of the experiment results revealed that the time spent in root canal preparation decreased as the vertical forces and rpm increased (p<0.05). Also, the effects of rpm were greater than those of the vertical forces within the normal vertical force range ($\beta$-weight test). 2. Observation of the deformation of GT rotary file revealed that deformation increases in a direct correlation with the vertical force increase and in a reverse correlation with the rpm decrease. In the case of the vertical forces close to the normal range, the probability of GT rotary file deformation were quite different depending on the rpm changes. In the case of greater vertical forces, the occurrences of deformation of the file were more frequent regardless of the rpm changes. 3. Deformation and breakage of file were also commonly observed in the expended time measurement experiments and GT rotary file deformation experiments in which low speed rpm (150rpm) was used and at the curved portion of the resin block.

  • PDF

Relationship Between the Dose of Clodronate and Serum Level of Alkaline Phosphatase, Calcium, and Phosphate During Orthodontic Tooth Movement

  • Choi, Josefina;Baek, Seung-Hak;Chang, Young-Il
    • Journal of Korean Dental Science
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 2010
  • Objective : To evaluate the relationship between the dose of Clodronate and serum level of alkaline phosphatase (ALP), calcium (Ca), and phosphate (PO4) during orthodontic tooth movement MaterialS and MethodS: A total of 18 sex-matched Wistar rats (weight=180~230g, mean age=8 weeks) were allocated into the 2.5mM Clodronate (2.5C) group, 10mM Clodronate (10C) group, or control group (n=6 for each group). After the application of a nickel-titanium closed coil spring (force of 60g) between the upper central incisors and first molars (UFM), 2.5C, 10C, or saline was injected every third day into the subperiosteum of the alveolar bone adjacent to UFM for the experimental and control groups. The animals were sacrificed 17 days later. Trunk blood was quickly collected into a heparinized tube and centrifuged at 2,000 rpm for 20 min. The plasma was used for the biochemical assays of the serum level of ALP, Ca, and PO4. Kruskall-Wallis test and Mann-Whitney test with Bonferroni correction were performed for the statistical analyses. Results : Dose-dependent increase in the level of ALP (P<0.01) and decrease in the level of Ca (P<0.001) were observed among the control, 2.5C, and 10C groups. Although there was no significant difference in PO4 between the 2.5C and 10C groups, the 10C group showed a significantly higher level of PO4 than the control group (P<0.01). Conclusion : Since Clodronate induced significant dose-dependent change in the serum level of ALP, Ca, and PO4 during orthodontic tooth movement, orthodontists should consider these biochemical markers not only as a diagnostic tool for bone turnover rate but also as a monitoring tool for orthodontic tooth movement.

  • PDF

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

  • Jang, Ju-Kyong;Kwak, Sangwon;Choi, Ga Young;Ha, Jung-Hong;Choi, Sung-Baik;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.53 no.10
    • /
    • pp.743-750
    • /
    • 2015
  • Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

  • Kim, Do-Yoon;Lim, Bum-Soon;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at $36.5^{\circ}C$. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.

Position estimation and control of SMA actuators based on electrical resistance measurement

  • Song, Gangbing;Ma, Ning;Lee, Ho-Jun
    • Smart Structures and Systems
    • /
    • v.3 no.2
    • /
    • pp.189-200
    • /
    • 2007
  • As a functional material, shape memory alloy (SMA) has attracted much attention and research effort to explore its unique properties and its applications in the past few decades. Some of its properties, in particular the electrical resistance (ER) based self-sensing property of SMA, have not been fully studied. Electrical resistance of an SMA wire varies during its phase transformation. This variation is an inherent property of the SMA wire, although it is highly nonlinear with hysteresis. The relationship between the displacement and the electrical resistance of an SMA wire is deterministic and repeatable to some degree, therefore enabling the self-sensing ability of the SMA. The potential of this self-sensing ability has not received sufficient exploration so far, and even the previous studies in literature lack generality. This paper concerns the utilization of the self-sensing property of a spring-biased Nickel-Titanium (Nitinol) SMA actuator for two applications: ER feedback position control of an SMA actuator without a position sensor, and estimation of the opening of a SMA actuated valve. The use of the self-sensing property eliminates the need for a position sensor, therefore reducing the cost and size of an SMA actuator assembly. Two experimental apparatuses are fabricated to facilitate the two proposed applications, respectively. Based on open-loop testing results, the curve fitting technique is used to represent the nonlinear relationships between the displacement and the electrical resistance of the two SMA wire actuators. Using the mathematical models of the two SMA actuators, respectively, a proportional plus derivative controller is designed for control of the SMA wire actuator using only electrical resistance feedback. Consequently, the opening of the SMA actuated valve can be estimated without using an extra sensor.

Determination of Cadmium, Copper, Lead, Nickel, and Zinc in Sediments by ID-ICP/MS (동위원소희석 질량분석법에 의한 저니토 중의 카드뮴, 구리, 납, 니켈, 아연의 정량)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Suh, Jung-Kee;Han, Myoung-Sub
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.297-303
    • /
    • 2000
  • Isotope-dilution inductively coupled plasma mass spectrometry was used to determine trace amounts of Cd, Cu, Pb, Ni and Zn in sediment. Sediment samples were dissolved by microwave digestion with addition of mixed acid ($HNO_3$, HF and $HClO_4$). Lead was determined after separation of alkaline and alkaline earth metals by an ammonium pyrrolidenedithiocarbarmate (APDC) solvent extraction. The other elements were determined after separation of iron, tin and titanium by hydroxide precipitation. Recovery efficiency of the analyte elements was not satisfactory, but most of matrix elements causing the isobaric interference could be effectively eliminated by the separation. Good agreement was achieved with the certified values in the analysis of the two sediment reference materials.

  • PDF

The Evaluation of Electrolytic Nitrate Removal Efficiency of TiO2 Nanotube Plate (TiO2 nanotube plate의 질산성질소 전기분해 효율 평가)

  • Kim, Da Eun;Lee, Yongho;Han, Heeju;Choi, Hyo yeon;Pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.612-621
    • /
    • 2018
  • In this study, $TiO_2$ nanotube plate and metal electrodes(Copper, Nickel, Stainless Steel, Aluminum, Tin, Titanium) were compared on cathodic reduction of nitrate ($NO_3{^-}-N$) during electrolysis. The electrochemical characteristics were compared based on electrochemical impedance spectroscopy (EIS). The surface morphology was obtained using scanning electron microscopy (SEM) method. Brunauer-Emmett-Teller (BET) method was implemented for the specific surface area analysis of the cathodes. To study kinetics, 90 minute batch electrolysis of nitrate solution was performed for each cathodes. In conclusion, under the condition of relatively low ($0.04 A\;cm^{-2}$) current density, $TiO_2$ nanotube plate showed no surface corrosion during the electrolysis, and the reaction rate was measured the highest in the kinetic analysis.