• 제목/요약/키워드: Nickel-Titanium

Search Result 214, Processing Time 0.028 seconds

Cyclic behavior of superelastic shape memory alloys (SMAs) under various loading conditions

  • Hu, Jong Wan
    • Journal of Urban Science
    • /
    • v.7 no.1
    • /
    • pp.5-9
    • /
    • 2018
  • The nickel-titanium shape memory alloy (SMA), referred to as Nitinol, exhibits a superelastic effect that can be restored to its original shape even if a significant amount of deformation is applied at room temperature, without any additional heat treatment after removal of the load. Owing to these unique material characteristics, it has widely used as displacement control devices for seismic retrofitting in civil engineering fields as well as medical, electrical, electronic and mechanical fields. Contrary to ordinarty carbon steel, superelastic SMAs are very resistant to fatigue, and have force-displacement properties depending on loading speed. The change for the mechanical properties of superelastic SMAs are experimentally inviestigated in this study when loading cycle numbers and loading speeds are different. In addition, the standardized force-displacement properties of such superelastic SMAs are proposed with an aim to efficiently design the seismic retrofitting devices made of these materials.

Correction of dental Class III with posterior open bite by simple biomechanics using an anterior C-tube miniplate

  • Ahn, Hyo-Won;Chung, Kyu-Rhim;Kang, Suk-Man;Lin, Lu;Nelson, Gerald;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.270-278
    • /
    • 2012
  • In the correction of dental Class III molar relationship in skeletal Class II patients, uprighting of the mandibular posterior segments without opening the mandible is an important treatment objective. In the case reported herein, a C-tube miniplate fixed to the lower labial symphysis and connected with a nickel-titanium reverse-curved archwire provided effective uprighting of the lower molars, without the need of orthodontic appliances on the mandibular anteriors. Using this approach, an appropriate magnitude of force is exerted on the molars while avoiding any negative effect on the mandibular anteriors.

Characterization of Ni SALICIDE process with Co interlayer and TiN capping layer for 0.1um CMOS device (Co-interlayer와 TiN capping을 적용한 니켈실리사이드의 0.1um CMOS 소자 특성 연구)

  • 오순영;지희환;배미숙;윤장근;김용구;황빈봉;박영호;이희덕;왕진석
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.671-674
    • /
    • 2003
  • 본 논문에서는 Cobalt interlayer 와 Titanium Nitride(TiN) capping layer를 Ni SALICIDE의 단점인 열 안정성과 sheet resistance 와 series 저항을 감소시키는데 적용하여 0.lum 급 CMOS 소자의 특성을 연구하였다. 첫째로, Ni/Si 의 interface 에 Co interlayer 를 증착하여 Nickel Silicide의 단점인 열 안정성 평가인 700℃, 30min의 furnace annealing 후에 낮은 sheet resistance와 누설전류를 줄일 수 있었다. 두번째로, TiN caping layer를 적용하여 실리사이드 형성시 산소와의 반응을 막아 실리사이드의 표면특성을 향상시켜 누설전류의 특성을 개선하였다. 결과적으로 소자의 구동전류 향상, 누설전류 저하, 낮은 면저항으로 소자의 특성을 개선하였다.

  • PDF

Fabrication of Porous TiNi Alloys by Self-propagating High-temperature Synthesis (자전연소반응에 의한 TiNi 다공체 합금 제조에 관한 연구)

  • 이상진;권대환;배승열;안인섭;김유영
    • Journal of Powder Materials
    • /
    • v.9 no.2
    • /
    • pp.96-102
    • /
    • 2002
  • In the present study, equiatomic porous TiNi shape-memory alloys have been successfully prepared by self-propagating high-temperature synthesis (SHS) using elemental titanium and nickel powders. The porous TiNi alloys thus obtained have an open porous structure with about 64 vol.% porosity, and the pore size is about 1.8 mm. The effect of preheating temperature on the microstructure have been investigated. It is found that the pore size increases with increasing preheating temperature. Moreover, the preheating temperature was shown to have a significant effect on the microstructrue of the SHS-synthesized porous TiNi shape memory alloys.

Acoustic Emission Characteristics of Plasma Sprayed Ceramic Coating Layer after Salt Spray (플라즈마용사 세라믹코팅 피막부식재의 음향방출 특성)

  • 김귀식;박경석;홍용의
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.344-349
    • /
    • 2001
  • This paper was to investigate of a adhesiveness for the plasma sprayed coating materials did salt spray by acoustic emission method in tensile loadings. The powders used for the coating were nickel aluminum composite powder Ni-4,5wt.%Al and titanium dioxide powder Ti02. These powders were coated on a carbon steel S45C by plasma spray method. The salt solution was a 5% NaCl and the salt spray times were 2, 5 and 10 hours respectively. The salt solution penetrated into the surface of the substrate through pore of the coating layer built in the process of plasma spay. Corrosion productions formed on the surface of substrate. The adhesiveness between the substrate and the coating layer is weaken by corrosion and the exfoliation initiated chiefly at the corrosion surface of the substrate. The AE events and energy of the corroded coating specimens decreased as the salt spray times increased.

  • PDF

Human sensory feedback research in the armstrong laboratory

  • Weisenberger, Janet M.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.83-100
    • /
    • 1997
  • The Human Sensory Feedback Laboratory, park of the Armstrong Laboratory at Wright-Patterson Air Force Base, Ohio, is involved in the development and evaluation of systems that provide sensory feedback to the human operator in telerobotic and virtual environment applications. Specific projects underway in the laboratory are primarily concerned with the information provided by force and vibrotactile feedback to the operator in dextrous manipulation tasks. Four specific research projects are described in the present report. These include : 1) experiments evaluating a 30-element fingertip display, which employs a titanium-nickel shape memory alloy actuator design to provide vibrotactile feedback about object shape and surface texture ; 2) of a fingertip force-feedback display for 3-dimensional information about object shape and suface texture ; 3) use of a force- feedback joystic to provide "force tunnel" information in pilot pursuit tracking tasks ; and 4) evaluations of a 7 degree-of-freedom exoskeleton used to control a robotic arm. Both basic and applied research questions are discussed.

  • PDF

CLINICAL CONSIDERATION IN THE CHOICE OF ALIGNMENT ARCHES (치아배열을 위한 교정용 탄선의 선택에 대한 고찰)

  • Park, E. Woong;Kim, Sang Cheol
    • The korean journal of orthodontics
    • /
    • v.19 no.3
    • /
    • pp.79-86
    • /
    • 1989
  • The wires for initial alignment purposes require a combination of excellent strength, excellent springiness, and a long rang of action. The variables in selecting appropriate arches for alignment are the arch wire material, its diameter, and the distance between attachments. The principle that there should be 0.02 inch clearance for initial wires means that an .016 diameter wire is the largest that should be considered for initial alignment in the .018 slot system. The three major possibilities for alignment arches are multistranded steel wires, nickel-titanium wires, and single-stranded steel wires with loops. The excellent choice for initial alignment in .018 bracket is .014 steel wire with loops.

  • PDF

SHAPE MEMORY THIN FILM OF TITANIUM-NICKEL FOR MICROACTUATOR FORMED BY SPUTTERING

  • Takei, A.;Ishida, A.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.424-429
    • /
    • 1996
  • Thin films of Ti-Ni alloy were formed by sputtering under various Ar gas pressures and r. f. powers to investigate the optimum sputtering conditions and to demonstrate their shape memory effect. The composition and structure of the films were examined by electron micro-probe analysis and scanning electron microscope. These films were annealed in order to crystallize them. The mechanical property of the annealed films was evaluated by a conventional bending test. The transformation tmeperatures were determined by differential scanning calorimetry. The shape memory behaviour was examined quantiatatively by changing in sample temperature under various constant loads. It was found that the Ar gas pressure had a critical effect on the mechanical property of the thin film,s although the r.f. power also affected it. The films formed at a high Ar gas pressure were too brittle to be bent successfully. However, the films formed at a low Ar gas pressur could be bent and their shape memory behavior was found to be comparable with that of bulk Ti-Ni alloys.

  • PDF

Effect of Sinter/HIP Technology on Properties of TiC-NiMo Cermets

  • Kollo, Lauri;Pirso, Juri;Juhani, Kristjan
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.627-628
    • /
    • 2006
  • The present work is a study on the argon gas pressure effects of Sinter/HIP sintering on microstructure and strength of different grades of TiC-NiMo cermets. Titanium carbide in the composition of different grades of TiC-NiMo cermets was ranged from 40 to 80 wt.% and the ratio of nickel to molybdenum in the initial powder composition was 1:1, 2:1 and 4:1 respectively. On the sintered alloys, the main strength characteristic, transverse rupture strength (TRS) was measured. Furthermore, the microstructure parameters of some alloys were measured and the pressure effect on pore elimination was evaluated. All the results were compared with common, vacuum sintered alloys. The TRS values of TiC-NiMo cermets could be considerably improved by using Sinter/HIP technique, for high-carbide fraction alloys and for alloys sintered at elevated temperatures.

  • PDF

Working length change by instrumentation in curved canals

  • Jo, Jeong-Im;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.589-590
    • /
    • 2003
  • Mesiobuccal or distobuccal canals of maxillary molars and mesiobuccal or mesiolingual canals of mandibular malars were selected. Forty specimens were divided into four groups according to the instruments used : stainless steel K-files($MANI^{\circledR}$, Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex $NT^{TM}$, Brassler, Savannah, U.S.A.), $Profile^{\circledR}$, and $ProTaper^{TM}$ (Dentsply-Maillefer, Ballaigues, Switzerland). Occlusal surface of each tooth and root apex were flattened by using diamond burs and sandpaper. Before instrumentation, a rubber stop was fixed with glue to the #10 K-files of initial working length in each tooth.(omitted)

  • PDF