• 제목/요약/키워드: Nickel-Chromium

검색결과 210건 처리시간 0.025초

철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가 (Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests)

  • 신재호;이동훈;이재봉;신성호
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

Creq/Nieq비에 따른 AISI 304L 및 AISI 316L 스테인리스강 용접부의 미세조직 및 전기화학적 양극분극 평가 (Evaluations of Microstructure and Electrochemical Anodic Polarization of AISI 304L and AISI 316L Stainless Steel Weld Metals with Creq/Nieq Ratio)

  • 김연희;장아영;강동훈;고대은;신용택;이해우
    • 대한금속재료학회지
    • /
    • 제48권12호
    • /
    • pp.1090-1096
    • /
    • 2010
  • This pitting corrosion study of welded joints of austenitic stainless steels (AISI 304L and 316L) has addressed the differentiating solidification mode using three newly introduced filler wires with a flux-cored arc welding process (FCAW). The delta ferrite (${\delta}$-ferrite) content in the welded metals increased with an increasing equivalent weight ratio of chromium/nickel ($Cr_{eq}/Ni_{eq}$). Ductility dip cracking (DDC) was observed in the welded metal containing ferrite with none of AISI 304L and 0.1% of AISI 316L. The potentiodynamic anodic polarization results revealed that the $Cr_{eq}/Ni_{eq}$ ratio in a 3.5% NaCl solution didn't much affect the pitting potential ($E_{pit}$). The AISI 316L welded metals with ${\ddot{a}}$-ferrite content of over 10% had a superior $E_{pit}$ value. Though the AISI 316L welded metal with 0.1% ferrite had larger molybdenum contents than AISI 304L specimens, it showed a similar $E_{pit}$ value because the concentration of chloride ions and the corrosion product induced severe damage near the DDC.

가축분뇨 퇴비·액비의 비료성분 및 중금속 함량에 관한 연구 (A Study on the Nutrient Composition and Heavy Metal Contents in Livestock Manure Compost·Liquefied Fertilizer)

  • 안태웅;김동민;이흥수;신현상;정유진
    • 한국물환경학회지
    • /
    • 제37권4호
    • /
    • pp.306-314
    • /
    • 2021
  • The application of organic fertilizer could be accompanied by potential hazards to soil and humans due to trace metals. Livestock manure compost·liquefied fertilizer is a well-established approach for the stabilization of nutrients and the reduction of pathogens and odors in manures, which can be evaluated as compost·liquefied. In this study, the livestock manure compost·liquefied fertilizers produced at 333 liquid manure public resource centers and liquid fertilizer distribution centers were collected from May to December 2019. The nutrient content (nitrogen, phosphorus, and potassium), physicochemical properties, and heavy metal content were investigated. The livestock manure compost·liquefied fertilizer was measured using a mechanical maturity measurement device. The organic matter, arsenic, cadmium, mercury, lead, chromium, copper, nickel, zinc, E. coli (O157:H7), Salmonella, etc. of the livestock manure compost·liquefied fertilizers were analyzed. The average heavy metal content in the livestock manure compost·liquefied fertilizer was as follows: Cr 2.9 mg/kg (0.2~8.7 mg/kg), Cu 20.4 mg/kg (1.6~74.1 mg/kg), Ni 1.3 mg/kg (0.4~4.2 mg/kg), and Zn 79.8 mg/kg (3.0~340.7 mg/kg). Although large-scale organic fertilizer plants and resources recycling centers produce good organic (liquid) fertilizers with proper components, it is necessary to standardize livestock manure compost·liquefied fertilizer in order to facilitate efforts to turn livestock manure into useful resources.

핵연료 크러드가 원전 재관수 열전달에 미치는 영향 (Effects of Crud on reflood heat transfer in Nuclear Power Plant)

  • 유진;김병재
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.554-560
    • /
    • 2021
  • 크러드는 원자력 발전소 운전 시 핵연료 표면에 침적되는 철-니켈-크롬 등의 금속 산화물로 이루어진 다공성 물질이다. 그 두께는 수십 ㎛ 수준이다. 발전소의 냉각재상실사고 시 크러드 층은 핵연료-냉각수 열전달에 영향을 미치게 되어 원전 안전성 측면에서 그 영향을 살펴보는 것이 중요하다. 일반적으로 크러드는 열저항으로 인하여 핵연료 온도를 높이는 부정적 효과가 있는 것으로 알려져 있었다. 그 이유는 크러드에 의하여 핵비등, 최소막비등온도, 단상증기 열전달, 임계열유속, 막비등 열전달 등 2상유동 열전달 특성을 고려하지 않았기 때문이다. 본 연구에서는 다공성 크러드 물질의 물성치를 모델링하고 이를 국내 원전안전해석 코드인 SPACE에 탑재하였다. 크러드는 다공성 고체 물질이고 표면이 거칠기 때문에 최소막비등온도와 단상증기 열전달이 증가할 것으로 예상된다. 이에 최소막비등온도와 단상증기 열전달이 최대 피복재 온도 및 급냉에 미치는 영향을 평가하였다. 시험 계산은 기존 FLECHT-SEASET 재관수 실험 장치에 기반으로 수행되었다. 계산결과 최소막비등온도가 상승하여 급냉시간이 줄어들었다. 단상증기 열전달의 경우 약 20% 증가할 때까지는 최대 피복재 온도가 하강하였다. 크러드 층이 원전 안정성 측면에서 긍정적인 효과가 있음을 확인하였다.

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제43권4호
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.

치과용 Ni-Cr 합금의 조성에 따른 세라믹의 색차 분석 (Ceramic color differences of dental Ni-Cr alloy by compositional change)

  • 김사임;김태연;김세하;강정규;이정환
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.168-174
    • /
    • 2021
  • Purpose: This study was conducted to investigate alloys spectrophotometrically including yttrium of nickel-chromium (Ni-Cr) alloys, which are used as substitutes for the regulation of beryllium and provide helpful improvements in Ni-Cr alloys. Methods: Four groups of specimens (ZN, ZY, SN and EM) were prepared for analysis. Color parameters were measured with a spectrophotometer, and color difference (∆E*) was calculated. The t-test and one-way analysis of variance test were used to determine significant difference, and the Tukey test was used to identify where the differences were. To measure the spectroscopic reflectivity, the spectroscopic reflectance was measured and converted into CIE L*, a*, b* color system. Results: The ∆E* value of each metal ceramic group after opaque firing of Ni-Cr alloy with and without yttrium was <2, and the total group color difference (∆E*) was below 1 in the dentin ceramic all experimental group. However, the a* and b* values of the metal ceramic groups were higher than that in the lithium disilicate all ceramic group, and the chroma was higher than the natural tooth. The brightness of all experimental groups was similar to that of the shade guide sample. Conclusion: Yttrium added to Ni-Cr alloys showed similar CIE L*, a*, b* values to Ni-Cr alloys that did not contain yttrium, indicating that yttrium had no effect on color in metallic ceramic systems.

낙동강 상류 서식 어류의 부위별 중금속 분포 특성 (Studies on Heavy Metal Characteristics by Part of Fish in Upper Region of Nakdong River)

  • 권희원;김영훈;김정진
    • 자원환경지질
    • /
    • 제55권1호
    • /
    • pp.19-27
    • /
    • 2022
  • 낙동강 상류지역의 안동댐, 임하댐, 영주댐 유역에 서식하는 물고기에 대하여 근육부, 아가미, 위, 간 부위로 분리하여 중금속 분석을 수행하였다. 분석한 물고기는 갈겨니(dark chub), 강준치(skygager), 꺽지(coreoperca herzi), 끄리(Korean piscivorous chub), 누치(cornet fish), 떡붕어(Japan crucian carp), 메기(catfish), 배스(bass), 붕어(crucian carp), 쏘가리(mandarin fish), 잉어(carp), 참마자(long-nosed barbel), 치리(Korean sharpbelly) 등 13개 어종으로 ICP/MS를 이용하여 분석하였다. 분석 결과 전체 평균 농도를 기준으로 근육부는 수은을 제외한 모든 중금속 항목에서 다른 부위에 비해 낮았다. 아가미 부위는 크롬, 망간, 니켈, 납, 위 부위는 아연, 간 부위는 철, 구리, 비소, 카드뮴이 다른 금속에 비해 높은 농도값을 나타내었다.

XRD와 XRF를 이용한 무명이(無名異)의 구성 성분 연구 (A Study on the Constituents of Pyrolusitum by XRD and XRF)

  • 이민우;최고야;이영종
    • 대한본초학회지
    • /
    • 제33권6호
    • /
    • pp.87-92
    • /
    • 2018
  • Objectives: The aim of the study was to analyze the constituents of Pyrolusitum, which was used to eliminate static blood and inflammation, to establish the basis of clinical application. Methods: Qualitative analysis was performed by X-Ray Diffraction (XRD) using the sample as a powder, and the elemental content of granular sample was measured by X-Ray Fluorescence (XRF). 1 M hydrochloric acid and 5% sodium hydroxide aqueous solution were added to observe the changing shape, respectively. Results: Qualitative analysis by XRD revealed that the Pyrolusitum samples used in the study contained quarts and kaolinite. Quantitative analysis by XRF revealed that the manganese content in the samples used in the study was 6.16% on average, while iron was contained the highest amount of 22.99%. The minor constituents include 1.08% of titanium, 0.30% of barium, 0.18% of lead, 0.06% of zirconium, 0.05% of chromium, 0.04% of zinc, 0.03% of cadnium, 0.02% of nickel, 0.01% of arsenic, 0.01% of copper, 0.01% of rubidium, 0.01% of strontium, 0.00% of molybdenum, respectively. And cobalt, which is reported to be a constituent of Pyrolusitum, was not detected at all in the samples of the study. Pyrolusitum was dissolved in dark brown when it was put into 1 M hydrochlorid acid, and there was brown precipitate when sodium hydroxide solution was added to Pyrolusitum and stirred. Conclusions: It was found that manganese and iron were the major constituents of Pyrolusitum, and it could be identified by using concentrated hydrochloric acid and sodium hydroxide solution.

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

Elemental Composition of the Soils using LIBS Laser Induced Breakdown Spectroscopy

  • Muhammad Aslam Khoso;Seher Saleem;Altaf H. Nizamani;Hussain Saleem;Abdul Majid Soomro;Waseem Ahmed Bhutto;Saifullah Jamali;Nek Muhammad Shaikh
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.200-206
    • /
    • 2024
  • Laser induced breakdown spectroscopy (LIBS) technique has been used for the elemental composition of the soils. In this technique, a high energy laser pulse is focused on a sample to produce plasma. From the spectroscopic analysis of such plasma plume, we have determined the different elements present in the soil. This technique is effective and rapid for the qualitative and quantitative analysis of all type of samples. In this work a Q-switched Nd: YAG laser operating with its fundamental mode (1064 nm laser wavelength), 5 nanosecond pulse width, and 10 Hz repetition rate was focused on soil samples using 10 cm quartz lens. The emission spectra of soil consist of Iron (Fe), Calcium (Ca), Titanium (Ti), Silicon (Si), Aluminum (Al), Magnesium (Mg), Manganese (Mn), Potassium (K), Nickel (Ni), Chromium (Cr), Copper (Cu), Mercury (Hg), Barium (Ba), Vanadium (V), Lead (Pb), Nitrogen (N), Scandium (Sc), Hydrogen (H), Strontium (Sr), and Lithium (Li) with different finger-prints of the transition lines. The maximum intensity of the transition lines was observed close to the surface of the sample and it was decreased along the axial direction of the plasma expansion due to the thermalization and the recombination process. We have also determined the plasma parameters such as electron temperature and the electron number density of the plasma using Boltzmann's plot method as well as the Stark broadening of the transition lines respectively. The electron temperature is estimated at 14611 °K, whereas the electron number density i.e. 4.1 × 1016 cm-3 lies close to the surface.