• 제목/요약/키워드: Nickel chloride

검색결과 115건 처리시간 0.02초

치과 보철물 합금 성분중 니켈, 코발트, 크롬 및 구리에 대한 감작률에 관한 조사 연구 (SENSITIVITY TO NICKEL, COBALT, CHROME, & COFFER IN DENIAL ALLOYS)

  • 박영미;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.155-166
    • /
    • 1992
  • In dentistry, precious metal alloys are, mainly due to economic factors, increasingly displaced by alternatives containing Ni-Cr-Co. There are some reports where hypersensitive reactions to Ni-Cr-Co alloys are presented and discussed. The reactions reported vary from mucosa contact stomatitis to generalized dermatitis without any oral mucosal reaction. The purpose of this study was to investigate the incidence of nickel, chrome, cobalt and copper, and to know whether subjects with positive skin reaction to nickel would also demonstrate adverse intraoral reaction to a non-precious metal nickel. The patch tests were performed in 81 subjects(male 39, female 42) and nickel sulfate 5% aq., potassium bichromate 0.5% at., cobalt chloride 2% aq., & copper sulfate 1% aq., were used for test allergens. And then the intraoral tests were performed in 16 subjects, 8 subjects with positive allergic skin reaction to nickel and 8 subjects with negative allergic skin reaction. A pure metallic nickel plate was attached to the buccal side of the upper second premolar. The results are as follows : 1. The frequency of nickel sensitivity was 9.9% (2 men, 6 women), cobalt was 4.9% (1 man, 3 women), and chrome was 2.5% (2 men) respectively and there was no positive reaction to copper 2. The positive reactions were 8 of 23 (34.8%) with a history of jewelry allergic reactions and 3 of 58 (5.1%) without a history of jewelry allergic reactions. 3. Three of 8 subjects with positive skin reaction. gave reactions to the metal plates.

  • PDF

니켈쌀파메이트 전주층의 실시간 잔류응력 (Real-time Internal Stress of Nickel Sulfamate Electroform)

  • 김인곤;강경봉;이재근;권식철;김만;이주열
    • 한국표면공학회지
    • /
    • 제38권1호
    • /
    • pp.14-20
    • /
    • 2005
  • The control of internal stress is extremely important in electroforming because of the deliberately low adhesion between the electro form and the mandrel. Excessive tensile or compressive stress can cause distortion, separation problem, curling, peeling or separation of electroform prematurely from the mandrel, buckling and blistering. Nickel sulfamate bath has been widely used in electroforming because of its low internal stress and moderate hardness. In this study, real-time stress sensor has been used for stress control in chloride-free nickel sulfamate bath for 400 mm x 300 mm x 500 ㎛ nickel electroform. It was found that compressive stress found at low current density indicated the contamination of electrolyte, which is very useful in procuring buckling and peeling of electroform. No compressive stress is allowed for plate electroform. The real-time stress can also be used for accurate stress control of nickel electroform. The tensile stress was found to be increased slightly with increase in nickel electroform thickness, i.e., from initial 1.47 ksi to 2.02 ksi at 320 ㎛.

다공성 탄소전극기지상의 무전해 니켈도금에 관한 연구 (Electroless Nickel Plating on Porous Carbon Substrate)

  • 천소영;임영목;김두현;이재호
    • 마이크로전자및패키징학회지
    • /
    • 제17권1호
    • /
    • pp.75-80
    • /
    • 2010
  • 다공성 탄소전극기지 위의 무전해 니켈도금에 관한 연구를 하였다. 다공성 탄소전극기지로는 다공도가 20 ${\mu}m$ 이상인 것과 16~20 ${\mu}m$ 인 것을 사용하였다. 소수성인 탄소 표면은 $60^{\circ}C$ 이상의 암모니아 용액에 침적함으로써 그 표면 성질이 친수성으로 변화 되었고, 40분 이상 침적 시 접촉각이 $20^{\circ}$ 이하까지 측정 되었다. 도금욕의 pH가 증가됨에 따라 탄소기지 위에 도금된 니켈 도금층의 인의 석출량은 감소하였으며 니켈 도금층이 결정질 구조를 갖는 현상이 관찰되었다. 도금층의 두께는 pH가 증가함에 따라 증가하였다. 활성화 처리를 위한 $PdCl_2$의 농도에 따른 도금층의 두께 변화는 없었으나, 도금에 필요한 $PdCl_2$의 최소농도는 5 ppm 이상인 것으로 나타났다.

다공성 탄소전극상 무전해 니켈도금의 산성과 알칼리용액 비교 연구 (Comparison of Acidic and Alkaline Bath in Electroless Nickel Plating on Porous Carbon Substrate)

  • 천소영;강인석;임영목;김두현;이재호
    • 한국표면공학회지
    • /
    • 제43권2호
    • /
    • pp.105-110
    • /
    • 2010
  • Electroless nickel plating on porous carbon substrate for the application of MCFC electrodes was investigated. Acidic and alkaline bath were used for the electroless nickel plating. The pore sizes of carbon substrates were 16-20 ${\mu}m$ and over 20 ${\mu}m$. The carbon surface was changed from hydrophobic to hydrophilic after immersing the substrate in an ammonia solution for 40 min at $60^{\circ}C$. The contact angle of water was decreased from $85^{\circ}C$ to less than $20^{\circ}$ after ammonia pretreatment. The deposition rate in the alkaline bath was higher than that in the acidic bath. The deposition rate was increased with increasing pH in both acidic and alkaline bath. The content of phosphorous in nickel deposit was decreased with increasing pH in both acidic and alkaline bath. The contents of phosphorous is low in alkaline bath. The minimum concentration of $PdCl_2$ for the electroless nickel plating was 10 ppm in alkaline bath and 5 ppm in acidic bath. The thickness of nickel was not affected by the concentration of $PdCl_2$.

Fabrication of a Full-Scale Pilot Model of a Cost-Effective Sodium Nickel-Iron Chloride Battery Over 40 Ah

  • Lee, Dong-Geun;Ahn, Byeong-Min;Ahn, Cheol-Woo;Choi, Joon-Hwan;Lee, Dae-Han;Lim, Sung-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.398-405
    • /
    • 2021
  • To fabricate a full-scale pilot model of the cost-effective Na-(Ni,Fe)Cl2 cell, a Na-beta-alumina solid electrolyte (BASE) was developed by applying a one-step synthesis cum sintering process as an alternative to the conventional solid-state reaction process. Also, Fe metal powder, which is cheaper than Ni, was mixed with Ni metal powder, and was used for cathode material to reduce the cost of raw material. As a result, we then developed a prototype Na-(Ni,Fe)Cl2 cell. Consequently, the Ni content in the Na-(Ni,Fe)Cl2 cell is decreased to approximately (20 to 50) wt.%. The #1 prototype cell (dimensions: 34 mm × 34 mm × 235 mm) showed a cell capacity of 15.9 Ah, and 160.3 mAh g-1 (per the Ni-Fe composite), while the #2 prototype cell (dimensions: 50 mm × 50 mm × 335 mm) showed a cell capacity of 49.4 Ah, and 153.2 mAh g-1 at the 2nd cycle.

적출간 관류법을 이용한 카드뮴과 니켈의 간독성 비교 (Comparative Hepatotoxicity Assessment of Cadmium and Nickel with Isolated Perfused Rat Liver(IPRL))

  • 차봉석;장세진;이중우;왕승준
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권1호
    • /
    • pp.117-124
    • /
    • 2000
  • 목적 : 이 연구의 목적은 적출간 관류법을 통하여 염화니켈과 염화카드뮴의 간 독성을 비교하는 데에 두었다. 방법 : AST(aspartate aminotransferase ferase), ALT(alanine aminotransferase), LDH(lactate dehydrogenase) 등의 간기능을 나타내는 생화학적 지표와 관류속도를 간독성 지표로 이용하였으며 산소 소모율은 생존력을 나타내는 지표로 이용하였다. $300({\pm}50)g$ 정도의 흰쥐를 대조군과 각 노출군($50{\mu}M$$200{\mu}M$의 염화니켈과 염화카드뮴)에 5마리씩 총 25마리를 무작위로 할당하였다. Krebs-Ringer bicarbonate buffer solution을 관류액 용도로 제조하여 간문맥에 투입하고 간세포를 통과하여 vena cava로 배출되는 관류액을 일정한 시간 간격을 두고 계속적으로 채취하였으며 채취한 관류액은 간독성 지표를 측정하는 데에 이용하였다. 결과 : AST, ALT, LDH 모두 염하니켈 보다는 염화카드뮴 투여군에서 시간의 경과에 따라 큰 폭으로 증가하였으며 반복 측정된 2요인 분산분석을 실시한 결과, 통계적으로 유의한 차이를 나타냈다. 생존력은 두 물질 모두에서 시간의 경과에 따라 감소하는 경향을 나타냈다. 결론 : 결론적으로, 이 실험상에서는 염화니켈 보다 염화카드뮴의 간독성이 더욱 강한 것으로 드러났다. 적출간 더욱 강한 것으로 드러났다. 적출간 관류법의 특성상 급성 간독성 평가에서 적절한 기법으로 보이며 국내 연구에서도 이 방법이 널리 이용되기를 기대한다.

  • PDF

금속분말 Ni을 용해 한 Chloride Bath로 도금된 니켈후막의 입자크기에 대한 전류밀도 영향 (The Effects of Current Density on the Grain Size of Electroplated Thick Film Nickel(Ni) by Using Ni Metal Powder Dissolved Chloride Bath)

  • 박근용;엄영랑;최선주;박덕용
    • 한국자기학회지
    • /
    • 제23권1호
    • /
    • pp.12-17
    • /
    • 2013
  • 금속 분말 니켈(Ni)을 HCl용액에 용해시킨 후 $H_3BO_3$, KOH을 첨가하여 Chloride 도금용액을 제조 후 Ni plate 기판에 도금하였다. 도금두께는 $3{\mu}m$로 일정하게 유지하였다. 전류밀도를 $1{\sim}30mA/cm^2$ 변화를 준 결과 전류밀도를 증가시킬수록 Ni 후막표면이 거칠어졌다. $25mA/cm^2$$30mA/cm^2$에서는 균열된 표면형상을 관찰하였다. 또한 XRD patterns 변화를 관찰한 결과 전류밀도가 증가할수록 FCC(111)과 FCC(220) 및 FCC(311)상의 강도는 증가한 반면 FCC(200)상의 강도는 감소하는 것을 관찰하였다. 전기도금된 Ni의 수평 및 수직 자화 값을 측정하였는데 기판에 의한 수평자화 값이 크게 나왔고, 코팅층 두께가 증가할수록 수직자화 값이 커지는 것을 확인하였다.

니켈 전주층의 인장 물성(1) (Tensile Properties of Nickel Electroform(l))

  • 김인곤;이재근;강경봉;권식철;김만;이주열
    • 한국표면공학회지
    • /
    • 제38권1호
    • /
    • pp.21-27
    • /
    • 2005
  • Tensile properties and hardness of nickel electroform from chloride-free nickel sulfamate electrolyte at 50℃ and PH 4.5 were investigated. Current density varied from 20 to 60 mA/㎠. The deposit thicknesses were 360, 480 and 980 ㎛. It was found in 480 ㎛ thick electroform that highest tensile and yield strengths and hardness of 83.7 ksi, 53.6 ksi and 216 DPH, respectively were obtained at a current density of 40 mA/㎠ and they were slightly decreased at 20 and 60 mA/㎠. However the ductility was lowest of 7.9% at 40 mA/㎠. Such a high strength and low ductility at 40 mA/㎠ seems to be related to the narrower columnar structure than those of other current densities. All the deposits exhibited pronounced necking behavior. Tensile strength, yield strength and ductility increased as the nickel electroform thickens. Initial strong (200) texture developed on stainless steel mandrel decreased and (111) and (220) textures increased as deposit thickness increased, whereas (200) texture was preferred as the current density increased.

The Effect of Annealing Heat Treatment by Anodic Polarization Impedance Experiments for Cu-10%Ni Alloy

  • Lee, Sung-Yul;Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.536-541
    • /
    • 2015
  • Copper has been used extensively as an electric wire or as a base material in various types of machineries owing to its good electrical and thermal conductivity and good fabricating property, as well as its good corrosion resistance compared to iron. Furthermore, the copper-nickel alloy has significant corrosion resistance in severely corrosive environments. Although, cupro-nickel alloy shows better corrosion resistance than the brass and bronze series, this alloy also corroded in severely corrosive environments, including aggressive chloride ions, dissolved oxygen, and condition of fast flowing seawater. In this study, and annealing treatment at various annealing temperatures was carried out on the cupro-nickel (Cu-10%Ni) alloy, and the effects of annealing were investigated using electrochemical methods, such as measuring the polarization and impedance behaviors under flowing seawater conditions. The corrosion resistance increased by annealing compared to non heat treatment in the absence of flowing seawater. In particular, the sample annealed at $200^{\circ}C$ exhibited the best corrosion resistance. The impedance in the presence of flowing seawater showed higher values than in the absence of flowing seawater. Furthermore, the highest impedances was observed in the sample annealed at $800^{\circ}C$, irrespective of the present of flowing seawater. Consequently, the corrosion resistance of cupro-nickel (Cu-10%Ni) alloy in a severely corrosive environment can be improved somewhat by annealing.