• Title/Summary/Keyword: Ni-Ti instruments

Search Result 78, Processing Time 0.023 seconds

Effect of Internal Stress on Cyclic Fatigue Failure in ProTaper Universal (ProTaper Universal에 축적된 내부 응력이 피로 파절에 미치는 영향)

  • Jo, Yun-Sung;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.57-66
    • /
    • 2012
  • The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of ProTaper Universal. ProTaper Universal (Dentsply Maillefer) S1, S2, F1, F2, F3, F4 and F5 (25 mm length) were used in this study. To give the internal stress, the ProTaper Universal were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. The rotation speed was 300 rpm and torque value was 1.0 Ncm. ProTaper Universal were grouped by the induced number of internal stress and randomly distributed among one control group and three experimental groups (n=10). The four groups were Stress 0 (control), Stress 1, Stress 2 and Stress 3. These instruments were rotated until separation. For cyclic fatigue measurement, inclined plane was used and time for separation was recorded. It was statistically analyzed using two-way ANOVA and Duncan post-hoc test at 95% confidential level. In all ProTaper Universal, there was statistically significant decrease on time for separation in Stress 3. In F2 and F3, there were statistically significant difference between control group and all experimental groups. And in F4 and F5, Stress 2 and 3 groups showed significantly lower cyclic fatigue resistance from Stress 0 group. In the limitation of this study, cyclic fatigue failure of ProTaper Universal is influenced by accumulated internal stress.

INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE (측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향)

  • Min, Kyung-San;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro Gold NiTi files

  • Pedulla, Eugenio;Lo Savio, Fabio;La Rosa, Giusy Rita Maria;Miccoli, Gabriele;Bruno, Elena;Rapisarda, Silvia;Chang, Seok Woo;Rapisarda, Ernesto;La Rosa, Guido;Gambarini, Gianluca;Testarelli, Luca
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.25.1-25.10
    • /
    • 2018
  • Objectives: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal ($60^{\circ}$ angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.

Problems of Metallic Dental Instruments for Dental Use (치과에서 사용되는 금속치과기구의 임상적용시 문제)

  • 최한철
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.15-15
    • /
    • 2003
  • 치과재료에 사용되는 금속재료는 주로 스테인리스강, 타이타늄, Ni-Ti, Co-Cr등과 같은 특수합금이 주로 사용되고 있다. 이들 재료는 치과 보철물과 교정재료 및 충전재료로 주로 사용되고 있으며 그 외 치과에서 사용되는 기기나 기구에도 많이 활용되고 있다. 특히 치과 보철물을 사용하여 치료를 원하는 환자가 최근에 급격히 증가하면서 임플란트 고정체와 나사 등을 이용한 치료법의 연구와 개발이 필요하게 되어 세계적으로 연구와 투자가 활발히 진행되고 있다. 그러나 재료의 설계나 합금의 설계 및 제품의 설계상의 문제로 인하여 생체조직과 결합하는데 많은 문제점이 임상적으로 발생되고 있다. 즉 임플란트 표면의 생체적합성부여, 고정체와의 결합시 파절이나 풀림현상, 골에 고정체로 사용하는 나사의 강도와 내마모성문제 등이 개선되어야 할 문제점으로 남아있다. 또한 총의치에 사용되는 자석 어태치먼트의erosion-corrosion문제, 교정선의 탄성 과 마모저항문제 등은 앞으로 계속적인 연구를 행하여야할 과제로 남아있다. 또한 국소의치에서 사용되는 frame은 정밀주조법을 통하여 제조하며 주조상의 결함 등으로 인한 클라스프의 파절 문제점이 발생되고 있다. 따라서 본 연구에서는 치과재료로 사용되는 임플란트 고정체, 나사, 교정용 선등의 문제점을 고찰하고, 지금까지 이루어진 연구를 중심으로 최적의 개선 조건을 찾고자하였다. 최근첨단소재 및 금속재료를 사용하여 치과재료 합금을 설계할 수 있는 연구가 활발히 진행된다면 수입에 의존하고 있는 고가의 치과재료를 값이 싼 고성능의 제품으로 대체할 수 있는 효과가 클 것으로 생각된다.>$\rho$$\sub$0/=1.8 %. As t$\sub$Co/ increases, a transition from the regime of co-existence of superparamagnetic and ferromagnetic behaviors to ferromagnetic behavior was observed. Tunneling barrier called "decay length for tunneling" for the films having the thickness of Co layer from 1.4 to 1.6 nm was measured to be ranged from 0.004 to 0.021 ${\AA}$$\^$-1/.문에 기업간 관계를 연구하는 측면에서는 탐험적 연구성격이 강하다. 더 나아가 본 산업의 주된 연구가 질적이고 기업내부만을 연구했던 것에 비교하면 시초적이라고 할 수 있다. 또한 관계마케팅, CRM 등의 이론적 배경이 되고 있는 신뢰와 결속의 중요성이 재확인하는 결과도 의의라고 할 수 있다. 그리고 신뢰는 양사 간의 상호관계에서 조성될 수 있는 특성을 가진 반면, 결속은 계약관계 초기단계에서 성문화하고 규정화 할 수 있는 변수의 성격이 강하다고 할 수가 있다. 본 연구는 복잡한 기업간 관계를 지나치게 협력적 측면에서만 규명했기 때문에 많은 측면을 간과할 가능성이 있다. 또한 방법론적으로 일방향의 시각만을 고려했고, 횡단적 조사를 통하고 국내의 한 서비스제공업체와 관련이 있는 컨텐츠 공급파트너

  • PDF

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

THE COMPARISON OF CANAL SHAPING ABILITY BY ENGINE-DRIVEN NICKEL-TITANIUM FILE AND ENDOSONIC FILE IN CURVED CANAL (만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교)

  • Kim, Hyun-Ju;Oh, Won-Mann;Yang, Kyuo-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.758-767
    • /
    • 1995
  • The purpose of this study was to evaluate canal shaping ability after canal preparation by using engine-driven nickel-titanium file and endosonic file in curved canals. 30 mesiobuccal canals of molars extracted within recent 3 months were divided into 3 groups. Group I and group II were prepared by using engine-driven nickel-titanium Gates-Glidden drill type and the engine-driven nickel-titanium file type. Group III prepared by using en do sonic file. The image of preinstrumented canals was taken by X-ray. The image of postinstrumented canal was taken by X-ray in the same condition of preinstrumentation. A magnified X-ray image on magnifier screen was traced and then compared the preinstrumentated canal image with the postinstrumentated canal image by superimposing method. The following results were obtained : 1. In the change of canal curvature, the engine-driven nickel-titanium Gates-Glidden drill type showed the least change and the ultrasonically filing showed the greatest change. 2. In the percentage of canal enlargement, the engine-driven nickel-titanium file type was greatest at all level(p<0.05), the apex of all group was the greatest, the difference of ultrasonically filing group showed greater between apex and cervix. 3. The percentage of canal enlargement on convex side was greater than that of on concave side in apex of each group(p<0.05). In the ultrasonically filing group, both sides of canal enlargement showed sharply difference(p<0.01). 4. The percentage of canal enlargement on convex side was greater than that of on concave side in the third of cervix of the engine-driven nickel-titanium file type and the ultrasonically filling. The percentage of canal enlargement of convex and concave side in the third of middle of the engine-driven nickel-titanium Gates-Glidden drill type show a similar canal enlargement between convex side and concave side. As above result, the engine-driven nickel-titanium file type was greater in canal enlargement than the other instruments. The engine-driven nickel-titanium Gates-Glidden dirll type was efficient endodontic instrument for curved canal preparation because it was least change in canal curvature.

  • PDF

A COMPARISON OF MASTER APICAL FILE SIZE ACCORDING TO INSTRUMENTATION IN TYPE II ROOT CANAL (제2형 근관의 확대에 따른 최종근관장파일 크기의 비교)

  • Jeong, Eun-Ju;Lee, Dong-Kyun;Baek, Shin-Young;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.435-442
    • /
    • 2008
  • Type II root canal was defined that two canals leave the chamber and merge to form a single canal at short of the apex. The aim of this study was to analyse the master apical file (MAF) size according to various instrumentation techniques in the type II root canal when each canal was enlarged to working length. Eighty mesial roots of molar with ISO #15 initial apical file (IAF) size in type II root canals were randomly divided into four experimental groups with 20 teeth each. According to enlarging instruments, four groups are: K-$FLEXOFILE^{(R)}$ (KF), engine-driven Ni-Ti $P_{RO}T_{APER}{^{(R)}}$ (PT), HERO $Shaper^{(R)}$ (HS), $K^{3\;TM}$ (K3). All canals were enlarged to each working length with ISO #30 size: #30 in KF, F3 in PT, .04/30 in HS, and .06/30 in K3. The master apical file (MAF) size was confirmed by tactile sensation and universal test- ing machine (EZ test, Shimadzu Co., Kyoto, Japan). The mean MAF size was statistically compared using one-way ANOVA and Tukey HSD test at the 0.05 probability level. These results show that the MAF size was appeared one or two sizes larger than the final enlarging instrument when all canal in type II configuration were enlarged to each working length. Therefore, the clinician have to confirm the apical stop once more after instrumentation of type II root canal.

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF