스핀밸브 GMR(giant magnetoresistance) 구조를 갖는 Ta/NiFe/CoFe/Cu/NiFe/IrMn/Ta재료의 자유층에 의한 PHR (planar hall resistance) 특성을 이용한 자기 바이오센서를 제작하였다. PHR 소자는 사진식각 및 건식에칭 공정을 통하여 마이크로 사이즈로 제작되었다. 직경이 $2.8\;{\mu}m$인 단일 자기비드가 있는 경우와 자기비드가 없는 경우 자기장의 세기에 다른 PHR 신호를 측정하였으며, 직경이 $2.8\;{\mu}m$인 단일 자기비드 측정에 성공하였다. 따라서 본 연구에서 제작한 PHR센서는 자기비드 입자의 유무에 따른 출력 특성의 차이를 이용하여 단일 자기비드 측정이 가능한 고분해능 자기 바이오센서에 응용될 수 있다.
To reveal the spatial and temporal variability in the distribution, growth, and maturation of skipjack tuna Katsuwonus pelamis in the western tropical Pacific, we compared two El $Ni{\tilde{n}}o$-Southern Oscillation (ENSO) signals and the sea surface temperature (SST) in the main fishing area with fishery and biological data. An index of skipjack tuna distribution was calculated using Korean purse seine fishery data from 1985 to 2003. Biological data for skipjack tuna were collected monthly from Korean catches during the 1994-2003 period. The catch was more closely related to the SST in the main fishing area than to the ENSO signals. However, cross-correlated function analysis showed delayed interactions between abiotic and biotic factors. The El $Ni{\tilde{n}}o$ events preceded the eastward movement of the fishing center by 2-3 months. El $Ni{\tilde{n}}o$ had a positive effect on the skipjack tuna catch, and the change in the Southern Oscillation Index (SOI) preceded the catch fluctuation by ca. 5-7 months. In addition, negative El $Ni{\tilde{n}}o$ effects on gonad maturation and the mean length of skipjack tuna were detected with time lags of 12 and 7 months, respectively. The length frequency indicated that the regime-specific growth pattern at each discrete period seemed to be related to the ENSO.
진공증착방법으로 제작한 $Ni_{53}-Fe_{47}$ 박막에 관한 신형전류자기 기전력효과의, 전류와 자장 방향이 만드는 각 $\theta$ 의존성이, 자기저항효과의 $cos\;2{\theta}$, Hall 1효과의 경우 $sin\;{\theta}$임에 대하여 $sin\;2{\theta}$로 관측되고, 이 효과의 자장에 의존하는 전압변화율이 자기저 항효과의 비교할 때 차수가 다르게 큰 것이 조사된다. 이 효과가 2 Carrier형 모델로 이해할 수 있음을 이론적으로 확인된다.
Human activities have enhanced the influx of heavy metals to aquatic ecosystem and hanged the abiotic environment such as the sediments supporting benthic organisms. The levels of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn) in the benthic gastropod Oxyloma hirasei and the sediments around their habitat were investigated to examine heavy metal levels and the potential of the gastropod as a bioindicator. We detected different levels of heavy metals in the sediments of two wetland areas, Upo and Mokpo, in the relatively well-conserved Upo wetland, Ramsar Convention Area. Oxyloma hirasei had higher concentrations of heavy metals except Cr and Ni in their soft tissues than in their shells (Cd: $2.10{\sim}3.16$, Cu: $19.73{\sim}28.66$, Pb: $0.67{\sim}1.17$, Zn: $216.1{\sim}285.7\;{\mu}g/g$ dry weight in the soft tissues; Cr: $1.19{\sim}2.58$, Ni: $0.47{\sim}1.16\;{\mu}g/g$ dry weight in the shells). Differences in the Cd, Cu, Ni and Pb concentrations in O. hirasei soft tissues reflected differences in heavy metal concentrations in the sediments at the sampling sites. The coefficients of variation for Cd, Cu and Pb were lower than those for other metals in the soft tissues. Levels of Cd in the tissues of O. hirasei were the highest among the metals examined in this study. Therefore, the soft tissue of O. hirasei appears to be a promising bioindicator particularly for Cd.
본 연구에서는 RF 스퍼터를 이용하여 SiC 기판위에 AlN막을 증착하고 급속 열처리 (RTA) 공정의 온도에 따른 AlN/4H-SiC 구조의 전기적, 재료적 특성에 대한 영향을 분석하였다. 400도에서 RTA 공정을 진행한 Ni/AlN/4H-SiC SBD 소자의 온/오프 비율은 RTA 공정 전 그리고 600도에서 RTA 공정을 한 소자에 비해 약 10배정도 높은 값을 가졌다. 또한 오제이 전자현미경을 통한 원자성분 분석을 통해 증착한 AlN 층내의 존재하는 산소의 양이 후열 처리 조건에 따라 변화함을 확인하였고 소자의 온/오프 비율 그리고 온-저항 등 소자의 성능에 영향을 주는 것을 분석하였다. 추가적으로, 제작한 소자의 노출된 음향 주파수에 따른 전기적 특성변화를 분석하였다.
The changes of microstructure and hardness of TLP bonds of directionally solidified Ni base superalloy, GTD-111, with variation of homogenizing and aging treatment were investigated. The specimens were bonded at 1403K for 7.2ks using different insert metals such as MBF-50, MBF-80 and MBF-90 and they were homogenized at 1393K with various holding time. At center of bonded interlayer homogenized for hold time 30h, the contents of aluminum and titanium were approximately 90% and 95% of base metal, respectively. In this study, aging was performed at three different kinds : one step aging ; 1113K $\times$ 16h, two step aging ; 1113K $\times$ 10h ⇒ 1103K $\times$ 10h, three step aging ; 1113K $\times$ 10h ⇒ 1103K $\times$ 8h ⇒ 922K $\times$ 24h. ${\gamma}$' volume fraction and hardness of joints were high in the sequence of one step, two step and three step aging, whereas ${\gamma}$' volume fraction and hardness of joints obtained by three step aging treatment were higher than those of raw material. Tensile properties of joints bonded with MBF-80 and MBF-90, homogenized at 1393K for 30h and then three step aged became excellent than those of raw material, however, joint bonded with MBF-50 was poor.
본 연구에서는 초음파 센서에 응용 가능한 $0.4Pb(Ni_{1/3}Nb_{2/3})O_3-0.6Pb(Zr_xTi_{1-x})O_3+0.5Wt%$$MnO_2$ 세라믹스에 Zr/(Ti+Zr)비를 0.37에서 0.41로 변화시킨 조성을 1175 $\sim$ 1200$^{\circ}C$ 온도에서 소결하여 이의 결정구조 및 미세조직을 분석하였고, 압전, 유전 특성을 고찰하였다. 본조성에서 x=0.385 조성에서 최대 유전상수 값 3490 이 나타났으며, 그 이상의 첨가에서는 감소하였다. 상경계 영역인 x=0.385 조성에서 $\varepsilon$r, $K_p$, $d_{33}$ 값이 최대값을 나타내었다. $0.4Pb(Ni_{1/3}Nb_{2/3})O_3-0.6Pb(Zr_xTi_{1-x})O_3+0.5Wt%$$MnO_2$, 세라믹스에서는 kp 와 $d_{33}$ 는 Zr/(Ti+Zr)비 0.385조성까지 증가하였다가 그 이상 조성에서 감소하였다. $1175^{\circ}C$에서 2시간 소결한 x=0.385조성에서 $\varepsilon$r=3490, kp=0.71, Qm=476의 우수한 압전 특성을 나타내었다.
산성 도금조에서 차인산나트륨을 환원제로 하는 무전해 도금법을 사용하여 직경 $4{\mu}m$의 PMMA(poly-methylmethacrylate)/HDDA(1,6-hexanedioldiacrylate) 단분산 가교 고분자 미립자에 니켈층을 코팅할 시 1) 전처리 조건변화, 2) 도금조 온도변화, 3) 도금조 pH 변화, 및 4) 초기 도금조 pH 조절 등에 따라서 도금속도, 도금면의 상태 및 도금 재현성을 관찰하였다. 무전해 도금에서의 전처리 과정은 모든 단계가 중요하였으나 특히 conditioning 및 acceleration 과정이 균일한 도금층을 형성하는데 중요하였고, 도금조 온도 및 pH의 상승에 따라서 도금속도가 증가하였으며, 특히 초기 도금조의 pH의 조절이 도금 재현성을 확보하는데 매우 중요하였다.
Purpose: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Material and Methods: A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo $T_1$-weighted images, fast spin-echo $T_2$-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results: Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion: With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.
각종 microwave용 통신기기 소자 및 고주파용 memory 소자로 사용하기 위해서 각형비가 크고 보자력이 작은 lithium ferrite를 개발하고 물리적인 특성을 조사하기 위하여 Li0.48-0.5xBi0.02Ni0.04ZnxFe2.46-0.5xO4의 조성식을 갖는 시편을 제조하였다. ZnO을 첨가하여 변화시킴에 따라 잔류자기(Bm)가 증가하고 보자력(Hc)이 낮아졌으나 각형비 R은 감소하였다. 105$0^{\circ}C$에서 소결한 시편의 경우 R=0.82, Hc=1.8Oe로 나타났고 110$0^{\circ}C$에서 소결한 시편의 경우 R=0.75 및 Hc=1.70Oe인 값을 얻었다. Tc는 463$^{\circ}C$로 측정되었고 주변온도 변화에 대한 Br값의 변화가 매우 안정된 0.09~0.11 값으로 나타났다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.