• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.025 seconds

Development of Stand-Alone Underground Water Pumping System using Photovoltaics System (태양광발전을 이용한 독립형 지하수 양수 시스템 개발)

  • Lee, Seung-Hun;Hwang, Jung-Hoon;Cho, Woon-Sik;Kim, Man-Il;Lee, Joon-Gee;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

Thermal Characteristics of a Solar and Gas-fired Receiver (태양열과 가스 연소열을 복합 적용한 흡수기의 열특성 연구)

  • Kang, Myeong-Cheol;Kim, Jin-Soo;Kang, Yong-Heack;Yoon, Hwan-Ki;Yu, Chang-Kyun;Lee, Sang-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.157-160
    • /
    • 2006
  • The Dish/Stirling system with the Stirling engine is currently used to convert solar energy directly to electrical energy successful operation of dish/Stirling system is supported by hybrid system, which will allow continuous operation driven by solar and combustion heat ins. The hybrid Receiver has to be provided with an additional combustion system. The heat pipe receiver and conbustion system were manufactured and tested for thermal characteristics of receiver. Maximum temperature difference along the heat pipe surface is $200^{\circ}C$. Emission measurements showed low NOx values of 28 to 46 ppm and very high CO values of 18 to 201 ppm.

  • PDF

Waste-to-Energy and Landfill Gas Utilization Potential in Indonesia

  • Yurnaidi, Zulfikar
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.313-320
    • /
    • 2009
  • Indonesian Ministry of Environment estimates that each year 170 cities and regencies in Indonesia produce 45,764,354.30 $m^3$ or approximately 11,441,091.08 ton of solid waste. Unfortunately, unsustainable management system has created a severe waste problem, hazardous to health and environment. This paper deals with the problem and offers some solutions. They are 3R (Reduce Reuse and Recycle), waste-to-energy concept and landfill gas (LFG) utilization. While 3R policy has been adopted by the government, the remaining two technologies are still dormant. Thus the paper provides a complete yet compact analysis of technology, economics, and environment aspect of waste-to-energy and LFG. Given the facts of waste production and management in Indonesia, the purpose is to encourage Government of Indonesia and other stake holders (including international community) to explore and exploit this potential. Potential of reducing waste negative externality while receiving extra revenue. Two bird with a stone.

  • PDF

Economic Evaluation of Liquid Air Energy Storage (LAES) System (액화 공기 에너지 저장 기술(LAES)의 경제성 분석)

  • Ko, Areum;Park, Sung-Ho;Ryu, Ju-Yeol;Park, Jong-Po
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Liquid air energy storage (LAES) using gas liquefaction has attracted considerable attention because of its mature technology, high energy density, few geographical constraints, and long life span. On the other hand, LAES has not yet been commercialized and is being developed recently. Therefore, few studies have performed an economic analysis of LAES. In this study, the levelized cost of electricity was calculated and compared with that of other energy storage systems. As a result, the levelized cost of electricity of LAES was $371/MWh. This is approximately $292/MWh, $159/MWh, $118/MWh, and $3/MWh less than that of the LiCd battery, VRFB battery, Lead-acid battery, and NaS battery. In addition, the cost was approximately $62/MWh and $195/MWh more than that of Fe-Cr flow battery and PHS. Sensitivity analysis of the levelized cost of electricity according to the main economic factors was performed, and economic uncertainty analysis was performed through a Monte-Carlo simulation. The cumulative probability curve showed the levelized cost of electricity of LAES, reflecting price fluctuations in the air compressor cost, electricity cost, and standing reserve hourly fee.

A Study on Reset of Examination Criteria for Energy Use Plan by Projet Sector (사업 분야별 에너지사용계획 검토기준 재설정에 관한 연구)

  • Suh, Kwang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6581-6589
    • /
    • 2013
  • This study reset the Examination Criteria for Energy Use Plan by the project sector so that the Consultation about Energy Use Plan would play an effective role in reaching the National Energy Policy Issues, and to prevent complaints from the superintendent of the project & agent engaged in the project. To achieve this aim, consultation case analysis was carried out from 2001 to 2010 and the National Energy Master Plan was reviewed. The predicted effect of energy savings calculated by reset Examination Criteria on the $1^{st}$ energy demand target at 2030 was 2.5%, the effect of new and renewable energy utilization on a new and renewable energy supply target at 2030 was 3% and the rate of $CO_2$ reduction to greenhouse gas emission BAU at 2020 was 1.1%.

Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir (저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실)

  • Bhang, Byeong Gwan;Woo, Sung Cheol;Lee, Wonbin;Choi, Jin Ho;Shin, SeungWook;Lee, ChulSung;Park, MiLan;Won, Changsub;Ahn, HyungKeun
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.

Study on the Development of Utilization System for Wasted Forest Products Biomass Energy (임산 폐기물의 연소 및 에너지이용 시스템 개발에 관한 연구)

  • Lee, Hyoung-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.307-319
    • /
    • 2005
  • 인류에게 있어 가장 중요한 연료의 역할을 충실히 해왔던 임산자원이 화석계 에너지원의 고갈과 환경오염 문제의 급부상으로 임산자원의 신재생에너지원으로서의 잠재력이 다시 관심의 대상이 되고 있다. 본 연구에서는 임산자원의 에너지화와 그 산업적 응용을 위하여 원료의 수급체계를 검토, 확립하는 한편, 폐목질자원을 펠릿화한 목재펠릿 연료의 제조공정을 국내 환경을 고려하여 고효율화하는 동시에 본 연료를 효과적으로 이용할 수 있는 시스템을 개발하고자 하였다.

  • PDF

A Study about Output Filter of Paralleled Three-Phase Grid-Connected PV Inverters

  • Vu, Trung-Kien
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.271-272
    • /
    • 2011
  • The rising popularity of renewable energy sources resulted in development of the units of higher rated powers. As a result of the limited power handling capacity of individual devices, paralleling is the choice to increase the equipment rating, while keeping the THD of the current at the PCC within the agency specified standards. And their typical power circuit configuration limits the stress on individual devices to an appreciable extent. The main scope of this paper is the analysis of filter structure in paralleling inverter system's operation. Simulation results are shown to verify the theoretical analysis.

  • PDF

Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water (방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가)

  • Kang, Keum-Seok;Kim, Ji-Young;Ryu, Moo-Sung
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF