• Title/Summary/Keyword: New energy system

Search Result 4,397, Processing Time 0.03 seconds

Environmental Effect Analysis for PV system using LCA (LCA를 이용한 태양광발전의 환경영향분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.11-16
    • /
    • 2007
  • This paper analyses the environmental effect of 100kw PV system installed in Tibet using Life Cycle Assessment(LCA). Then, energy payback time(EPT) and life-cycle CO2 emission rate are estimated based on life-cycle of the PV system. As a result of the estimation, 6 year of EPT and 20 g-C/kWh of CO2 emission rate are obtained. In China, average CO2 emission rate of fossil fuel power generation plant is 260 g-C/kWh. This shows that PV system would be very promising for global environmental issues. For advanced LCA, we need to collect detailed and various data about raw material of PV system.

  • PDF

Process Design and Selection of Operating Conditions for SMART System (SMART 시스템의 공정설계 및 조업조건 선정)

  • Ryu, Ho-Jung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • To check feasibility of SMART(Steam Methane Advanced Reforming Technology) system, conceptual design and sensitivity analysis of operating variables have been performed based on the design program of two-interconnected fluidized beds. Among three configurations of two-interconnected fluidized beds systems, the bubbling-bubbling system was selected as the best configuration. Process design results indicate that the SMART system is compact and feasible. Based on the selected operating conditions, the effects of variables such as process capacity, pressure, and weight percent of $CO_2$ absorbable component have been investigated as well.

Feasibility Study for Application of Frequency Regulation ESS in Cuba: Technological Effects on Improving Frequency Compensation (쿠바 주파수조정 ESS 운영 전략 검토: 주파수 보상 효과 분석)

  • Kim, Soo-Yeol;Lee, Seong-eun;Kim, Jin-tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.123-127
    • /
    • 2020
  • KEPCO has installed Frequency Regulation ESS (FR ESS) of 376 MW since 2015. Frequency Regulation is ancillary service to support stabilizing system frequency, which is divided into governor free and automatic generation control. KEPCO operates FR ESS as governor free application and leads FR ESS market with capability of diverse demonstration and operation experiences. To expand FR ESS role during transient states of power system, KEPCO has extended operating time of charging and discharging. KEPCO has also changed speed droop lower than before to improve contribution on frequency compensation, and acquired much experiences of differentiating bad cells from others. Based on these technologies and know-hows, KEPCO Research Institutes received request of feasibility study and technical cooperation for overseas FR ESS business. This paper suggests the simple and practical method for making technological feasibility study of FR ESS.

A Study on the Economic Analysis of the Energy Storage System in Customer (수용가용 전력저장시스템의 경제성분석에 관한 연구)

  • Kim, Jeongho;Jang, Junoh
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.47-54
    • /
    • 2014
  • Recently, BESS is considered as one of essential countermeasure for demand side management. However, an economic evaluation is critical issue for the introduction of power system because the cost of BESS is very high in present stage. Therefor, this paper presents economic evaluation method for customer use case by considering peak shaving function based on the real time price. From the case study on the model power system and educational customer, it is confirmed that the proposed method is a practical tool for the economic analysis of BESS. and analytical approach for the reliability assessment in radially operated distribution systems. The approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP (Non-Delivery Power) and NDE (Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of Energy Storage System. The results from a case study show that the proposed methods can be a practical tool for the reliability management in distribution systems including Energy Storage System.

The Investigation of Problems for Next Generation Energy System during Existing Urban Plan Stage (기존 도시계획 단계에서 차세대에너지시스템 적용시 문제점 검토)

  • Park, Jin-Young;Kim, Sam-Uel;Park, Yool;Lee, Sang-Jin;Lee, Jurng-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.190-195
    • /
    • 2009
  • Since the industrial revolution, the global environmental problems such as greenhouse gas accumulation and the average temperature increase have caused people's attention. 'Low Carbon, Green Growth' was presented to cope with these global concerns, as one of main policies of 2008 in Korea. The paradigm of a green urban development is started to concern the whole city's energy problems owing to realize 'Low Carbon, Green Growth' in the urban side. The government established a nation's basic energy plan for 20 years, and some local cities made efforts to develop new renewable energy such as the solar, wind and water energy which are suitable to each city's character. As a part of these efforts, the concept of U-Eco city is newly appeared to reflect upon ubiquitous technique, urban ecology and the next generation energy system. However, urban plan is difficult to adopt this next generation energy system with existing laws, regulations and technical systems. The new executive and systematic system is needed to realize the U-Eco city U-Eco for the management of an efficient city. In this study, the authors investigate the concept of the next generation energy system and U-Eco city to realize the energy-efficient city plan and analyze problems to occur during the application of them in an existing city plan. Then, the authors show the remedies to deal with occurred problems.

  • PDF

Status of Domestic Byproduct Hydrogen and Infrastructure (국내 부생수소 현황과 수소 유통 인프라)

  • Sim, Kyu-Sung;Kim, Jong-Won;Kim, Jung-Duk;Hwang, Gap-Jin;Kim, Heung-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.4
    • /
    • pp.330-338
    • /
    • 2002
  • A long-term energy system in the future is expected to be based on the ideal circulation system between water and hydrogen in the sense that the hydrogen prepared from water eventually returns to water again after its use. Currently, with respect to the hydrogen energy system, it is predicted that the turning-point at which the production cost of hydrogen will become to be lower than that of fossil fuels would be after 2010. However, fuel cell technology would be able to be practically used for the applications to the transportation vehicles and small-scale power sources from 2004, and therefore, an efficient construction of the infrastructure covering hydrogen production and supply systems would be required with short-/mid-term technologies for the $CO_2$ reduction associated with fossil fuel utilization. In this paper, the hydrogen quantity available in domestic market has been estimated focusing on the hydrogen by-produced from domestic industries, and also the infrastructure for hydrogen-driven vehicles like fuel cell cars has been reviewed.

The Effect of Mixing Region in Mixed Multiple Serpentine Flow-field to PEMFC Performance (혼합 다채널 사형 유로의 혼합영역이 PEMFC 성능에 미치는 영향)

  • Lee, Ji-Hong;Lee, Myeong-Yong;Kim, Hun-Ju;Lee, Sang-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.4
    • /
    • pp.265-273
    • /
    • 2009
  • Proton Exchange Membrane Fuel Cell (PEMFC) has low operating temperature and high efficiency. And PEMFC consists of many components as bipolar plate, gas diffusion layer, membrane etc.. Flow-field in bipolar plate roles path for transporting reactants to membrane. Therefore a design of flow-field has an effect on PEMFC's performance. In this study, Computational Fluid Dynamics (CFD) simulations were performed for comparing mixed multiple serpentine (MMS) flow-field and multiple serpentine (MS) flow-field. And we studied an effect according to change mixing region design in MMS flow-field. Finally the applicability of results is verified by performing CFD simulation about fixed MMS flow-field which is combined good designs.

A study on the Reforming of Methane by Carbon Dioxide on the Transition Metal Catalysts Supported Zeolite (제올라이트에 담지된 전이금속 촉매상에서 메탄의 이산화탄소 개질반응에 관한 연구)

  • Jeong, Heon-Do;Kim, Kweon-lll;Kim, Tae-Hwan;Lee, Byum-Suk;Park, Jong-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.69-80
    • /
    • 2003
  • Nickel catalyst has been used for natural gas reforming with carbon dioxide, In this study, catalyst support used was HY zeolite. The optimum loading of Ni in the catalysts was 13 wt%. The effect of promoters, such as Mg, Mn, and K, was also studied. The addition of promoters to Ni catalyst improved the stability of catalysts and carbon deposition on Ni catalyst was suppressed. The reforming reactivity of promoter-added Ni catalyst was higher than that of Ni catalyst without any promoters. SEM, XRD, BET, TGA and FTIR tests were tried to characterize the catalyst structure before and after reaction.

Production of Solid Fuel and Concurrent Treatment of Livestock waste Using Zero Discharge ACE System (무방류 ACE System을 이용한 유기성폐기물의 동시처리 및 에너지 기술 개발)

  • Lee, Haeng-Seog;Cho, Eun-Min;Tak, Jong-Ho;Lee, Jae-Hyeon;Lee, Jae-Won;Kim, Jeong-Eon;Choe, Seong-Gil
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.2
    • /
    • pp.20-23
    • /
    • 2012
  • 본 연구는 유기성폐기물을 처리하고 그것을 이용하여 고체연료 또는 퇴비를 생산하는 종합시스템에 관한 것이다. 유기성폐기물은 90% 전후의 높은 함수율을 나타내고 있기 때문에 처리에 중점을 두어야 할 부분이 수분 처리 방법이다. 따라서 기존의 처리방법으로는 고액분리하여 처리 후 하천에 방류하는 시스템에 의해 처리되고 있다. 하지만 본 연구에서는 기술개발의 차별화 및 선행기술의 회피 전략을 위해, 유기성폐기물의 수분을 건조시키는 방법으로 미생물이 유기성폐기물의 유기물을 분해하여 발생 되는 $80^{\circ}C$ 이상의 열에너지에 의해 수분을 제거하는 발열반응을 적용하여 수분을 제거하는 무방류시스 템이다. 뿐만 아니라 고체연료의 발열량을 높이기 위해서 무연탄, 코크스, 기름 등의 열량보조제를 첨 가하는 대신에 유기성폐기물을 첨가 한 후 적당한 발열반응 및 건조시켜 고체연료를 제조하는 방법으 로 4,000kcal/kg 이상의 높은 발열량을 얻을 수 있으며 불완전연소 등에 의한 2차 오염을 방지할 수 있는 기술이다. 따라서 친환경 미생물 발열반응에 의해 유기성폐기물을 저렴한 비용으로 액상 및 고상 을 동시에 처리 할 수 있으며, 고체연료를 제조할 수 있는 새로운 신기술이다.

A Construction Strategy of Spatial Data Warehouse for New & Renewable Energy (신재생에너지 공간 Data Warehouse 구축전략)

  • Kim, Kwang-Deuk;Yoon, Chang-Youl;Park, Jook-Hyuk
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.337-340
    • /
    • 2008
  • As a 'Construction of Information System on GIS based and Resource Map', establish the strategic of design about construction of Spatial Data Warehouse for New & Renewable Energy For Construction of comfortable Spatial Data Warehouse, It suggested The Construction of Spatial Data Warehouse on Block(Grid) Based with Analyze into the old Data & Method of Study. For Decide the Block(Grid) Size, We need The Study of Data & Method. Also, we expect Standardize The Process of Change & Apply with Data. make the best use of New & Renewable Energy Part

  • PDF