• 제목/요약/키워드: Neutron Source Efficiency

검색결과 27건 처리시간 0.234초

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

252Cf 선원을 이용한 즉발감마선 계측시스템 구성 (Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf)

  • 박용준;송병철;지광용
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.12-24
    • /
    • 2003
  • $^{252}Cf$ 중성자 선원을 이용한 즉발감마선 계측 시스템 (NIPS, Neutron Induced Promp ${\gamma}$-ray Spectroscopy)을 설계 및 구성하기 위하여, 시스템내의 감속제 및 차폐체등의 효과를 시험하고 감마선 바탕값과 Cl을 포함한 시료의 즉발 감마선을 계측하였다. 이를 위한 예비시험으로 한국원자력연구소 내에 있는 TLD 판독용 $^{252}Cf$ 선원을 이용하였으며 즉발감마선은 시스템 내부의 동축형 HPGe (GMX, 60% relative efficiency)과 시스템외부 (약 20m 거리)의 Notebook PC 중성자와 감마선의 바탕값을 측정하고, 바탕값을 최소로 할 수 있는 차폐체의 기하학적 구조를 고안하였다. 감마선 바탕값을 최소화하기 위하여 두 개의 HPGe 검출기를 이용한 감마-감마 동시계측법을 이용하였다. 이 실험 자료를 이용하여 최적의 NIPS 시스템을 구성하였다.

Consideration of the benefits of using a high current accelerator in BNCT

  • Cho, Ilsung;Min, Sun-Hong;Park, Chawon;Kim, Minho;Lee, Kyo Chul;Lee, Yong Jin;Hong, Bong Hwan;Lim, Sang Moo
    • 대한방사성의약품학회지
    • /
    • 제6권1호
    • /
    • pp.10-19
    • /
    • 2020
  • Boron Neutron Capture Therapy (BNCT) has the advantage of selectively removing cancer cells ingesting boron compounds. In this study, the benefits for treatment time and boron compound injection dose were compared between current neutron sources and a high current neutron sources to be developed in near future. The time-activity curve (TAC) of GBM (Glioblastoma) for one bolus injection was obtained by applying modified 3 compartment model. The treatment time was determined for an accelerator-based neutron sources at the present time and a high current accelerator based neutron source to be developed in the near future. In the case of the double amount of IAEA-recommended neutron flux, the treatment time was shortened to 15 minutes. In the case of high current accelerators, which are five times the amount of IAEA-recommended neutron flux, the irradiation time is within 5 minutes. The use of a high current accelerator based neutron source in BNCT is advantageous in terms of treatment time. In addition, it can increase the efficiency of use of neutrons and reduce the boron compound injection dose to patients, thus reducing pharmacological toxicity.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

Comparative optimization of Be/Zr(BH4)4 and Be/Be(BH4)2 as 252Cf source shielding assemblies: Effect on landmine detection by neutron backscattering technique

  • Elsheikh, Nassreldeen A.A.
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2614-2624
    • /
    • 2022
  • Monte Carlo simulations were used to model a portable Neutron backscattering (NBT) sensor suitable for detecting plastic anti-personnel mines (APMs) buried in dry and moist soils. The model consists of a 100 MBq 252Cf source encapsulated in a neutron reflector/shield assembly and centered between two 3He detectors. Multi-parameter optimization was performed to investigate the efficiency of Be/Zr(BH4)4 and Be/Be(BH4)2 assemblies in terms of increasing the signal-to-background (S/B) ratio and reducing the total dose equivalent rate. The MCNP results showed that 2 cm Be/3 cm Zr(BH4)4 and 2 cm Be/3 cm Be(BH4)2 are the optimal configurations. However, due to portability requirements and abundance of Be, the 252Cf-2 cm Be/3 cm Be(BH4)2 NBT model was selected to scan the center of APM buried 3 cm deep in dry and moist soils. The selected NBT model has positively identified the APM with a S/B ratio of 886 for dry soils of 1 wt% hydrogen content and with S/B ratios of 615, 398, 86, and 12 for the moist soils containing 4, 6, 10, and 14 wt% hydrogen, respectively. The total dose equivalent rate reached 0.0031 mSv/h, suggesting a work load of 8 h/day for 806 days within the permissible annual dose limit of 20 mSv.

원전 내 사용후핵연료 연소도 측정을 위한 중성자 검출기의 성능 평가 연구 (A Study on Performance Characteristics of Neutron Detector to Measure the Burnup Profile of Spent Fuel in NPP)

  • 박혜민;김태영;이인호;장대헌;송양수;이운장;함철민
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.293-297
    • /
    • 2023
  • The burnup profile of spent fuel should be determined accurately for the safety storage of spent fuel. In this study, a neutron detection system was developed as a part of basic research to analyze the burnup profile of spent fuel, and a performance was evaluated using a radiation source. The prototype of the neutron detection system was based on a 3He proportional chamber. The 3He proportional chamber is often used for neutron measurement and analysis because of its high neutron detection efficiency and simplicity for gamma ray rejection. For quantitative evaluation, tests were conducted using calibrated 252Cf and 137Cs sources. In the performance evaluation, a field applicability was verified by analyzing the detection characteristics according to the nuclide.

Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-ray

  • Jin, Dong-Sik;Hong, Yong-Ho;Kim, Hui-Gyeong;Kwak, Sang-Soo;Lee, Jae-Geun;Jung, Young-Suk
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.69-81
    • /
    • 2022
  • The method of measuring and classifying the energy category of neutrons directly using raw data acquired through a CZT detector is not satisfactory, in terms of accuracy and efficiency, because of its poor energy resolution and low measurement efficiency. Moreover, this method of measuring and analyzing the characteristics of low-energy or low-activity gamma-ray sources might be not accurate and efficient in the case of neutrons because of various factors, such as the noise of the CZT detector itself and the influence of environmental radiation. We have therefore developed an efficient method of analyzing radiation characteristics using a neutron and gamma-ray analysis algorithm for the rapid and clear identification of the type, energy, and radioactivity of gamma-ray sources as well as the detection and classification of the energy category (fast or thermal neutrons) of neutron sources, employing raw data acquired through a CZT detector. The neutron analysis algorithm is based on the fact that in the energy-spectrum channel of 558.6 keV emitted in the nuclear reaction 113Cd + 1n → 114Cd + in the CZT detector, there is a notable difference in detection information between a CZT detector without a PE modulator and a CZT detector with a PE modulator, but there is no significant difference between the two detectors in other energy-spectrum channels. In addition, the gamma-ray analysis algorithm uses the difference in the detection information of the CZT detector between the unique characteristic energy-spectrum channel of a gamma-ray source and other channels. This efficient method of analyzing radiation characteristics is expected to be useful for the rapid radiation detection and accurate information collection on radiation sources, which are required to minimize radiation damage and manage accidents in national disaster situations, such as large-scale radioactivity leak accidents at nuclear power plants or nuclear material handling facilities.

Implementation and benchmarking of the local weight window generation function for OpenMC

  • Hu, Yuan;Yan, Sha;Qiu, Yuefeng
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3803-3810
    • /
    • 2022
  • OpenMC is a community-driven open-source Monte Carlo neutron and photon transport simulation code. The Weight Window Mesh (WWM) function and an automatic Global Variance Reduction (GVR) method was recently developed and implemented in a developmental branch of OpenMC. This WWM function and GVR method broaden OpenMC's usage in general purposes deep penetration shielding calculations. However, the Local Variance Reduction (LVR) method, which suits the source-detector problem, is still missing in OpenMC. In this work, the Weight Window Generator (WWG) function has been developed and benchmarked for the same branch. This WWG function allows OpenMC to generate the WWM for the source-detector problem on its own. Single-material cases with varying shielding and sources were used to benchmark the WWG function and investigate how to set up the particle histories utilized in WWG-run and WWM-run. Results show that there is a maximum improvement of WWM generated by WWG. Based on the above results, instructions on determining the particle histories utilized in WWG-run and WWM-run for optimal computation efficiency are given and tested with a few multi-material cases. These benchmarks demonstrate the ability of the OpenMC WWG function and the above instructions for the source-detector problem. This developmental branch will be released and merged into the main distribution in the future.

Measurement of TOF of fast neutrons with 238U target

  • Li, Meng;Guan, Yuanfan;Lu, Chengui;Zhang, Junwei;Yuan, Xiaohua;Duan, Limin;Yang, Herun;Hu, Rongjiang;He, Zhiyong;Wei, Xianglun;Ma, Peng;Gan, Zaiguo;Yang, Chunli;Zhang, Hongbin;Chen, Liang;Qiu, Tianli;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1964-1969
    • /
    • 2021
  • We developed a Dual-PPACs detector for fast neutron measurements that consists of two sets of PPAC: conventional PPAC and fission PPAC. A238U(U3O8) coating is placed in the fission PPAC's anode, which is used as the neutrons conversion layer. An experiment was performed to measure neutron time-of-flight (TOF) in which 252Cf spontaneous fission source was used. An excellent time resolution of 164ps has been observed at 6 mbar in isobutene gas. With the excellent time resolution of Dual-PPACs detector, exact neutron energy can be extracted from the timing measurement. The experimental detection efficiency was 1.9 × 10-7, consistent with the efficiency of 2.5 × 10-7 given by a Geant4 simulation. Ultimately, the results show that the Dual-PPACs detector is a suitable candidate for measuring fast neutrons in the future CiADS system.