Analysis of Horizontal Neutron Reflectometer for Nanointerfaces Using McStas (나노 계면분석을 위한 수평형 중성자 반사율 측정장치의 McStas 시뮬레이션 분석)

  • Kwon, Oh-Sun;Shin, Kwan-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2007
  • A new horizontal neutron reflectometer has been designed and now under construction at the HANARO, 30 MW research reactor, in Daejon, Korea. We performed simulations of neutron ray-tracing to evaluate the performance of all of the optical components of the instrument with a Monte Carlo technique using McStas. The feasible wavelength of the incident neutron beam is $2.5{\AA}$. It produces a q-range up to $0.126{\AA}^{-1}$ with a supermirror as a deflector. Our studies showed improvement of the performance of the guide tube and monochromators. Although the performance is limited in q-range, it promises to be the first reflectometer in Korea for the study of free surfaces, which is currently in demand.

Montecarlo Simulation of the thermal neutron reflectometer with horizontal sample geometry for surface characterization of nanostructured thin films (나노 박막의 표면분석을 위한 열중성자 기반 수평형 반사율 장치의 몬테카를로 시뮬레이션)

  • Lee Chong Oh;Shin Kwanwoo;Lee Jeong Soo;Cho Sang Jin;Lee Chang Hee;So Ji Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.119-125
    • /
    • 2005
  • The horizontal reflectometer, which uses a neutron beam in the reactor, provides scientists a set of unique tools offering destruction-free investigation of biological membranes in the native-like environments in nano-meter scale. As an intial stage for the development of the first Korean neutron reflectometer with a horizontal sample geometry, we performed the instrumental simulation using MCSTAS, Monte Carlo Simulations of Triple Axis Spectrometers for neutron ray-tracing simulation. The results indicated that modeling of the overall instrument geometry based on the thermal neutron source with a wavelength of 2.55 $2.5{\AA}$ at HANARO was successfully performed, and further the optimization of the individual components of the instrument, including the collimator, monochromators, filter and supermirror has been made.

Vertical Neutron Reflectometer at HANARO (하나로 수직형 중성자 반사율 측정장치)

  • Lee J.S.;Lee C.H.;Hong K.P.;Choi B.H.;Choi Y.H.;Kim Y.J.;Shin K.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.132-137
    • /
    • 2005
  • Neutron reflectometer has been installed at HANARO, research reactor in Korea. It has vertical sample geometry and the wavelength of incident neutron beam is $2.459\;\AA$ Neutron fluxes at monochromator and sample position were $4.5\times10^9\;n/cm^2/sec,\;6.64\times10^6\;n/cm^2/sec4 those were measured by gold wire activation method. Also, some reference thin films such as d-PS, $SiO_2$ were measured and analyzedwith HANARO neutron reflectometer. As result of the work, it was certified that minimum reflectivity and available Q range were $10^{-6},\;and\;0.003\sim0.3\;\AA^{-1}$ respectively.

Surface Characterization of the d-PMMA Thin Films Treated by Oxygen Plasma (산소 플라즈마 처리된 d-PMMA 박막의 표면특성 분석)

  • Kim, Soong-Hoon;Choi, Dong-Jin;Lee, Jeong-Su;Choi, Ho-Suk
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.263-267
    • /
    • 2009
  • In order to improve the hydrophilic property on the surface of d-PMMA(deuterated poly-(methyl methacrylate)) film, it was exposed to oxygen plasma, All experimental conditions were same except to plasma exposure time that was varied from 0 to 180 s, The effects according to the exposure time were identified using contact angles, X-ray reflectometer(XRR), neutron reflectometer(NR), and X-ray photoelectron spectroscopy(XPS). By confirming that as the exposure time increases, water contact angle decreases while the composition of oxygen increases, it was confirmed that the composition of oxygen has a huge influence on improving the hydrophilic property. The physical characters as a function of the exposure time were investigated by the XRR. By analyzing complementally the results of the XRR, NR, and XPS, more detailed chemical bonding conditions were studied by obtaining not only composition of the carbon and oxygen but that of the hydrogen.

Study of the Magnetization Reversal Behavior of exchange-Biased System Using Polarized Neutron Reflectometry

  • Park, Sung-Kyun;Kim, Ki-Yeon;Kim, Ji-Wan;Choi, Hyeok-Cheol;Teichert, A.;You, Chun-Yeol;Shin, Sung-Cheol;Lee, Jeong-Soo;Fitzsimmons, M.R.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2011.06a
    • /
    • pp.3-3
    • /
    • 2011
  • Since the first discovery of exchange anisotropy on Co/CoO system[1], there have been numerous studies to explore the physical origin of exchange-biased system[2,3]. In this presentation, we report that how the polarized neutron reflectomery can be applied to study the magnetization reversal behavior of the exchange biased system. As an example, the detailed magnetization reversal mechanism of the exchange-biased Py(30 nm)/FeMn (0, 15, 30 nm)/CoFe(30 nm) trilayers was studied and found that the 15 nm antiferromagnetic FeMn layer mediates the magnetization reversal behaviors of both Py and CoFe layers through interlayer exchange bias coupling. We also update the current activities in polarized neutron reflectometer in HANARO.