• Title/Summary/Keyword: Network Tap

Search Result 67, Processing Time 0.025 seconds

A New Volt/Var Control of Substation for Distribution Volt/Var Regulation (배전계통 전압/무효전력조정을 위한 새로운 전압/무효전력제어 방식)

  • Choi, Joon-Ho;Kim, Jae-Chul;Son, Hag-Sig;Im, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.285-288
    • /
    • 2001
  • In this paper we proposed the on line volt/var control schemes of the load Tap Changer (LTC) transformer and shunt capacitor bank for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

Cooperation Algorithms of LTC and SC for Distribution Volt/Var Regulation (배전계통 전압/무효전력 보상을 위한 LTC변압기와 SC의 협조운전 알고리즘)

  • Choi, Joon-Ho;Kim, Jae-Chul;Nam, Hae-Kon;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.399-402
    • /
    • 2003
  • In this paper, the on line volt/var control algorithms of the food Load Tap Changer (LTC) transformer and Shunt Capacitor(SC) are proposed for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

Voltage Measurement-based coordinated Volt/VAR Control for Conservation Voltage Reduction (CVR을 위한 전압 계측 기반 전압 및 무효전력 협조제어)

  • Go, Seok-Il;Choi, Joon-Ho;Ahn, Seon-Ju;Yun, Sang-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1689-1696
    • /
    • 2017
  • In this paper, the voltage measurement-based coordinated Voltage/VAR control (VMCVVC) algorithm for conservation voltage reduction(CVR) is proposed. The proposed algorithm has the purpose of enhancing the CVR effect through coordinated control of the voltage control devices such as the distributed energy resources and the load tap changer(LTC) transformers. It calculates the references of the voltage control devices such that the bus voltages are maintained at as close to the lower operation limit as possible. For this purpose, firstly, the distribution system is divided into LTC transformer control zones through topological search. Secondly, the reactive power references of the reactive power control devices are determined such that the voltage profile of the section is flattened. Finally, the tap references of the LTC transformers are calculated to lower the voltage profile. The effectiveness of the proposed algorithm is demonstrated through case studies using IEEE test network.

An ICI Canceling 5G System Receiver for 500km/h Linear Motor Car

  • Suguru Kuniyoshi;Rie Saotome;Shiho Oshiro;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.6
    • /
    • pp.27-34
    • /
    • 2023
  • This paper proposed an Inter-Carrier-Interference (ICI) Canceling Orthogonal Frequency Division Multiplexing (OFDM) receiver for 5G mobile system to support 500 km/h linear motor high speed terrestrial transportation service. A receiver in such high-speed train sees the transmission channel which is composed of multiple Doppler-shifted propagation paths. Then, a loss of sub-carrier orthogonality due to Doppler-spread channels causes ICI. The ICI Canceler is realized by the following three steps. First, using the Demodulation Reference Symbol (DMRS) pilot signals, it analyzes three parameters such as attenuation, relative delay, and Doppler-shift of each multi-path component. Secondly, based on the sets of three parameters, Channel Transfer Function (CTF) of sender sub-carrier number 𝒏 to receiver sub-carrier number 𝒍 is generated. In case of 𝒏≠𝒍, the CTF corresponds to ICI factor. Thirdly, since ICI factor is obtained, by applying ICI reverse operation by Multi-Tap Equalizer, ICI canceling can be realized. ICI canceling performance has been simulated assuming severe channel condition such as 500 km/h, 2 path reverse Doppler Shift for QPSK, 16QAM, 64QAM and 256QAM modulations. In particular, for modulation schemes below 16QAM, we confirmed that the difference between BER in a 2 path reverse Doppler shift environment and stationary environment at a moving speed of 500 km/h was very small when the number of taps in the multi-tap equalizer was set to 31 taps or more. We also confirmed that the BER performance in high-speed mobile communications for multi-level modulation schemes above 64QAM is dramatically improved by the use of a multi-tap equalizer.

A Modified Delay and Doppler Profiler based ICI Canceling OFDM Receiver for Underwater Multi-path Doppler Channel

  • Catherine Akioya;Shiho Oshiro;Hiromasa Yamada;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2023
  • An Orthogonal Frequency Division Multiplexing (OFDM) based wireless communication system has drawn wide attention for its high transmission rate and high spectrum efficiency in not only radio but also Underwater Acoustic (UWA) applications. Because of the narrow sub-carrier spacing of OFDM, orthogonality between sub-carriers is easily affected by Doppler effect caused by the movement of transmitter or receiver. Previously, Doppler compensation signal processing algorithm for Desired propagation path was proposed. However, other Doppler shifts caused by delayed Undesired signal arriving from different directions cannot be perfectly compensated. Then Receiver Bit Error Rate (BER) is degraded by Inter-Carrier-Interference (ICI) caused in the case of Multi-path Doppler channel. To mitigate the ICI effect, a modified Delay and Doppler Profiler (mDDP), which estimates not only attenuation, relative delay and Doppler shift but also sampling clock shift of each multi-path component, is proposed. Based on the outputs of mDDP, an ICI canceling multi-tap equalizer is also proposed. Computer simulated performances of one-tap equalizer with the conventional Time domain linear interpolated Channel Transfer Function (CTF) estimator, multi-tap equalizer based on mDDP are compared. According to the simulation results, BER improvement has been observed. Especially, in the condition of 16QAM modulation, transmitting vessel speed of 6m/s, two-path multipath channel with direct path and ocean surface reflection path; more than one order of magnitude BER reduction has been observed at CNR=30dB.

Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network (배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

Issues and Improvement Methods of the Bridge Tab in Customer Premises Telecommunications Facilities for High-Speed Communication Network (초고속통신망을 위한 구내통신 설로설비의 브릿지 탭의 문제점과 개선 방안)

  • Min, Gyeong-Ju;Hong, Jae-Hwan;Nam, Sang-Sig;Kim, Jeong-Ho
    • The KIPS Transactions:PartC
    • /
    • v.13C no.7 s.110
    • /
    • pp.881-888
    • /
    • 2006
  • The position of the bridged tap is determined by that of the outlet in most modern apartments, since most of the indoor wiring utilizes the bus wiring structure when deploying the indoor communication line. These bridged taps deteriorate transmission performance in the specific frequency at the time of high-speed multimedia communication, which uses a high frequency bandwidth, since the duality of return loss worsens and line attenuation increases rapidly. As a result, analysis on this phenomenon is required. In this study, the test model is created by modeling the intercommunication facility of the apartment that is the most representative residential house type, and by understanding the structure and the environment of the indoor wiring. Also, how the bridge tap affects performance is analyzed when the VDSL service is provided, so that problems of intercommunication lines can be identified and methods for improving the proper intercommunication line can be suggested, which is suitable for accommodating high-speed multimedia service of the future.

Automatic Meter Reading System for Water-Supply (상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로)

  • Seo, Chang-Gab;Park, Young-Jae
    • Journal of Digital Convergence
    • /
    • v.7 no.3
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

Research Regard to Necessity of Smart Water Management Based on IoT Technology (IoT 기술을 활용한 스마트 물관리 필요성에 관한 연구)

  • Choi, Young Hwan;Kim, Yeong Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.4
    • /
    • pp.11-18
    • /
    • 2017
  • The Objective of this Study is to Prove the Effectiveness of a Smart Water Management(SWM) Technology. The SWM Technology can Reduce the Production Cost using Internet of Thing(IoT) Technology that Utilizes Remote Metering of Consumer's Water usage and Reduce the Leakage of Supply Facilities. The SWM Demonstration Model Installed a Remote Water Leakage Sensor, Smart Metering and Micro Multi Sensor in Water Supply Facility, and Provided Real-Time Monitoring of the Operation Status. Consumers can be Provided the usage of Tap Water and the Water Puality through a Smart Phone Application. At this Time, we Surveyed Whether Consumers save the Tap Water or Drinking Directly using the Tap Water usage Information. Also, this Study is to Verify the Degree of Improvement of Water Supply Rates and Drinking Water Rate, and to Decrease Consumer's Complaints, Operating Costs, and Water Consumption by the SWM Technology. It is also Established a SWM Model Combined with the IoT Sensor at Supply Facilities, operator monitoring system and explored recovery solution detected events. It means the upbringing of the domestic water industry by developing the related technologies and spreading the SWM to advanced levels.

Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System (분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choe, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF