• Title/Summary/Keyword: Network Installation

Search Result 647, Processing Time 0.028 seconds

Impact Analysis of Transportation Network by The Installation of Kiss & Ride Zone (Kiss & Ride Zone 설치에 따른 교통망 영향 분석)

  • Hong, Ki Man;Baek, Ba Ruem;Kim, Hyun Myung
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.145-156
    • /
    • 2013
  • PURPOSES : This research is a study on the changes in the road network of the surrounding area is installed according to the Kiss & Ride Zone. METHODS : Estimating the transportation mode of students by using the Metropolitan household Surveys(2006) and estimating the O/D by Kiss & Ride ratio with the estimated data, then being applied to a method of reducing the number of lanes for certain sections of the road which would be installed with Kiss & Ride Zone. RESULTS : The reason why it is different for delay resolving time and the affected roads as the Kiss & Ride percentage change, was the impact of the Kiss & Ride Zone's installation position. CONCLUSIONS : The purpose of the study was to analyze the impact of the road network in accordance with the installation of Kiss & Ride Zone by using speed and queue delay resolving time, and it is a need to develop a quantitative evaluation technique which was using various indicators in impact analysis according to the installation of the traffic safety facilities in the future.

Maximum Torque Control of IPMSM with Adaptive Learning Fuzzy-Neural Network (적응학습 퍼지-신경회로망에 의한 IPMSM의 최대토크 제어)

  • Ko, Jae-Sub;Choi, Jung-Sik;Lee, Jung-Ho;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.309-314
    • /
    • 2006
  • Interior permanent magnet synchronous motor(IPMSM) has become a popular choice in electric vehicle applications, due to their excellent power to weight ratio. This paper proposes maximum torque control of IPMSM drive using adaptive learning fuzzy neural network and artificial neural network. This control method is applicable over the entire speed range which considered the limits of the inverter's current md voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using adaptive teaming fuzzy neural network and artificial neural network. The hybrid combination of neural network and fuzzy control will produce a powerful representation flexibility and numerical processing capability. Also, this paper proposes speed control of IPMSM using adaptive teaming fuzzy neural network and estimation of speed using artificial neural network. The back propagation neural network technique is used to provide a real time adaptive estimation of the motor speed. The proposed control algorithm is applied to IPMSM drive system controlled adaptive teaming fuzzy neural network and artificial neural network, the operating characteristics controlled by maximum torque control are examined in detail. Also, this paper proposes the analysis results to verify the effectiveness of the adaptive teaming fuzzy neural network and artificial neural network.

  • PDF

Optimal valve installation of water distribution network considering abnormal water supply scenarios (비정상 물공급 시나리오를 고려한 상수도관망 최적 밸브위치 결정)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.719-728
    • /
    • 2019
  • Valve in water distribution network (WDN), that controls the flow in pipes, is used to isolate a segment (a part of WDN) under abnormal water supply conditions (e.g., pipe breakage, water quality failure event). The segment isolation degrades pressure and water serviceability in neighboring area during the water service outage of the segment. Recent hydraulic and water quality failure events reported encouraging WDN valve installation based on various abnormal water supply scenarios. This study introduces a scenario-based optimal valve installation approach to optimize the number of valves, the amount of undelivered water, and a shortest water supply path indicator (i.e., Hydraulic Geodesic Index). The proposed approach is demonstrated in the valve installation of Pescara network, and the optimal valve sets are obtained under multiple scenarios and compared to the existing valve set. Pressure-driven analysis (PDA) scheme is used for a network hydraulic simulation. The optimal valve set derived from the proposed method has 19 fewer valves than the existing valve set in the network and the amount of undelivered water was also lower for the optimal valve set. Reducing the reservoir head requires a greater number of valves to achieve the similar functionality of the WDN with the optimal valve set of the original reservoir head. This study also compared the results of demand-driven analysis (DDA) and the PDA and confirmed that the latter is required for optimal valve installation.

Network Type Distributed Control System with Considering Data Collision (데이터 충돌을 고려한 네트워크형 분산 제어 시스템)

  • Choi, Goon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2015
  • Network type distributed control system uses a communication line which is named the BUS to exchange a data among the sub-systems. Usually, on the bus, only one data must be exited at one time, so the control algorithm to prevent collision or to manage a priority of data is important. Including CAN Protocol, many kind of FieldBus which are used for distributed control system, prevent data collision by controlling transmission time. But, a system which have to make a control signal or get a data from a sensor at fixed time will be met a problem when it is composed by using a network type distributed control structure. In this paper, some of these cases will be discussed and solutions be proposed for preventing a data collision. Also, using Arago Disk System which have a structure for inner loop control, the validity of the proposed methods will be verified.

A Study on Evaluation for Risk Level in Transmission Network Connected with Renewable Energy (신재생에너지 계통 연계에 따른 송전망 Risk Level 평가에 대한 연구)

  • Kim, Sung-Yul;Moon, Sang-Kun;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.87-95
    • /
    • 2011
  • A Renewable Portfolio Standard(RPS) is a regulation that requires the increased generation of energy from renewable energy sources such as solar, wind, fuel cell, small hydro, biomass and geothermal. By environmental, technical and these regulatory reasons, the amount of renewable energy sources will be increased in a network. However, it is hard to assess risk of a transmission network with large scale renewable energy sources because the output characteristics of renewable energies are intermittent. This paper evaluates effects of a transmission system with supplemental large scale renewable energies into the existing system. To evaluate these effects, a methodology for risk level of components in a network is proposed considering steady state and contingency N-1 in this paper. We consider line current and bus voltage in each state of a network.

Security Issues & Application in Korea SCADA

  • Kim, Hak-Man;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.95-100
    • /
    • 2007
  • The importance of communication security is increased in the power industry. The representative communication network of power industry is the SCADA(Supervisory Control and Data Acquisition) systems. The SCADA system has been used for remote measurement and control in the power industry. Recently, many studies of SCADA network security have been carried out around the world. In this paper, we introduce recent security issues in the SCADA network and propose the application of a symmetric encryption method to the Korea SCADA network.

A Study on the Validation Methodology of Network Analysis Applications in Energy Management Systems (계통운영시스템 계통해석 프로그램 검증 방안에 관한 연구)

  • Cho, Yoon-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.27-36
    • /
    • 2014
  • Network analysis applications in energy management systems play a key role in the economic and reliable operation of power systems. In order to provide operators with useful network information, the accurate results of topology processing, state estimation, power flow, and contingency analysis must be simulated. This paper proposes a validation methodology of network analysis applications in energy management systems. The energy management systems was checked to ensure that it meets the originally specified functions based on the proposed methodology. In addition, the performance of state estimation is evaluated with the reference of the proposed methodology. The proposed methodology is being conducted by energy management systems and the Korean power systems have been utilized for the test systems.

A study on Using Web Browser for openness of Building Automation System (빌딩자동제어 시스템 개방화를 위한 Web 네트워크 활용방안)

  • 홍원표;이원규;박원국
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.163-168
    • /
    • 2000
  • This paper proposes the new concept & design method and implementation of LonWorks network system for remote monitoring & lighting dimming control and telemetry using Web network. The Experimental LonWorks network system for telemetry & remote monitoring and control are designed and fabricated. As a result, it is verified that LonWorks is open, interoperable, reliable network system from the experimental results, especially, it seamlessly links the data and control networks, allowing the IP(internet) network to be treated as an extension of the LonWorks networks, and vice versa.

  • PDF