• Title/Summary/Keyword: Neonate

Search Result 456, Processing Time 0.034 seconds

The degree of paternal attachment to neonate (아버지의 신생아에 대한 애착정도)

  • 김지영
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.2
    • /
    • pp.330-340
    • /
    • 1995
  • This study was conducted to find out the degree of paternal attachment to neonate, and to identify factors affecting paternal attachment. The main purpose was to make the base data for nursing intervention to improve parternal attachment. The subjects of this study were 20 fathers whose partners have delivered premature neonate and 30 fathers whose partners have delivered normal neonate in 3 university hospitals in Seoul. Data were collected from Feb. 10 to Apr. 10 1994 by self report questionaires. The instrument for this study was based on 7 kinds of characteristics of paternal attachment by Greenberg St Morris(1974), and developed by re-searcher The statistical methods for data analysis were percentage, mean, standard deviation, 1-test, ANOVA with S.P.S.S. program. The conclusions are as follows. 1. Fathers had the high degree of paternal attachent to neonate, but were afraid of active touch. 2. The factors that affect paternal attachment were delivery odor, past experience about own father except delivery pattern, pregnancy plan, sex of nonate. 3. There were not significant correlations between paternal attachment and early visual contact frequency of father-neonate. 4. In the degree of paternal attachment, though normal neonate father showed somewhat higher result than premature neonate father, there was not statistically significant difference between two groups(t=-1.83, P=0.076). But in the character of tactail awarness there were significant differences between two groups, hence nursing interventions are needed to help the premature neonate's father bring early tactile con-tact. Pother research about factors affecting paternal attachment to neonate and high risk neonate as well as low birth weight neonate is reguired.

  • PDF

The Paternal Attachment to Neonate in One Hospital (일 병원 신생아 아버지의 부성애착)

  • Oh, Jin-A;Oh, Young-A;Nam, Young-Hui
    • Korean Parent-Child Health Journal
    • /
    • v.8 no.2
    • /
    • pp.137-146
    • /
    • 2005
  • This study was conducted to find out the paternal attachment to neonate, and to identify factors affecting paternal attachment. The purpose was to make the base data for nursing intervention to improve paternal attachment. The subjects of this study were 93 fathers whose partners have delivered normal neonate in 1 hospital in Busan. Data were collected from Sep. 1th to Oct. 31th 2005 by a self-report questionnaire. The instrument for this study was based on 7 kinds of characteristics of paternal attachment by Greenberg & Morris(1974), and modified by researchers. The statistical methods for data analysis were percentage, mean, standard deviation, t-test, ANOVA with SPSS program Ver 10. The conclusions are as follows. Fathers had the high degree of paternal attachment to neonate. But, there were not significant correlations between paternal attachment and the father's demographic characteristics, pregnancy plan, delivery pattern, delivery order, sex of neonate and past experience. Also there were not significant correlations between paternal attachment and early visual contact frequency of father-neonate. Further research about factors affecting paternal attachment to neonate and high risk neonate as well as low birth weight neonate is required.

  • PDF

Air Flow in a Neonate Incubator: Flow Visualizations, Hot-Wire Velocity Measurements and Computational Fluid Dynamics (신생아 보육기의 공기유동에 관한 유동가시화, hot-wire 속도계측 및 전산유동 해석)

  • Kim, Young-Ho;Kwon, Chi-Ho;Yoo, Seoung-Chool
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.162-168
    • /
    • 2001
  • In the present study, flow visualizations, hot-wire velocity measurements and computational fluid dynamics were performed in order to determine complicated air flow characteristics in a neonate incubator. In this study, following conclusions can be made: (1) The flow visualization technique developed in the present study revealed an enough qualitative information for the flow field in the neonate incubator. Flow structures in a neonate incubator with a realistic three-dimensional shape was successfully visualized the present study. (2) Results from the flow visualization were relatively in good agreements with those obtained from the computational fluid dynamics. (3) Velocities very near the neonate measured by the hot-wire anemometer were relevant to those obtained from the computational fluid dynamics. (4) Temperatures were higher at the neck region and the medial aspect of both thighs, but lower in both extremities. (5) Small vortices between the neonate and the mattress might interfere with convective and evaporative heat transfers on the neonate's surface. In the fluid dynamic aspect, it is important to eliminate the formation of these small vortices for the design of incubator chamber.

  • PDF

Middle Cerebral Artery Aneurysm in a Premature Neonate

  • Choi, Chan-Young;Lee, Chae-Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.371-373
    • /
    • 2013
  • Intracranial aneurysms in the neonate are very rare and their clinicopathological findings remain unclear. We report a 26-day-old premature neonate who underwent microsurgical clipping on the ruptured middle cerebral artery bifurcation aneurysm successfully with a review of relevant literature.

Surgical Management of a Large Right Coronary Artery to Left Ventricle Fistula in a Neonate: A Case Report

  • Yu Ri Lee;Eun Seok Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.49-52
    • /
    • 2023
  • A fistula from the right coronary artery draining into the left ventricle is a rare form of coronary artery fistula. Here, we describe the case of a symptomatic neonate with a large fistula of this type. The neonate was successfully treated with surgical closure of the fistula.

Flow Visualizations and Hot-Wire Measurements on Air Flow in Two Different Neonate Incubators

  • Kim, Young-Ho;Yoo, Seoung-Chool;Kwon, Chi-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1051-1060
    • /
    • 2001
  • Flow visualizations and hot-wire measurements on the inside flows of two different incubators are presented in this paper. An anatomically-correct neonate model was fabricated using the rapid prototyping machine, based on the 3-D scanned data. The result showed that air flow in the incubator was affected not only by the air circulation system but also by the design of incubator chamber. Large rotating motions were located around the corners of free space. A number of small eddies were found in regions of high shear flow, in areas such as that between the air inlet and the neonate. But, these small eddies were found to be stationary at that locations. Those small eddies might interfere with convective and evaporative heat transfers from the neonate. This study has led to a better understanding of flow mechanism in an incubator chamber and provided the guidance needed for the advancement of improved computational fluid dynamic models.

  • PDF

Ultrasound-guided Needle Aspiration of Cranial Epidural Hematoma in a Neonate

  • Lee, Dong-Hoon;Lee, Sang-Weon;Lee, Tae-Hong;Ban, Ji-Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.61-63
    • /
    • 2006
  • We report a unique case of a neonate with an epidural hematoma induced by vacuum extraction. The epidural hematoma, communicating with a cephalhematoma through a linear skull fracture, disappeared after ultrasound-guided needle aspiration. The patient quickly recovered and one month later computed tomography revealed a complete resolution of the epidural hematoma.

Cardiac Fibroma in Neonate - A Case Report - (신생아에서 발생한 심장 섬유종;1례 보고)

  • 정성규
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1261-1263
    • /
    • 1992
  • Primary cardiac fibroma of the left ventricular myocardium is a rare tumor of the heart which is usually located within the anterior wall and /or septum of the left ventricle and is the second most common cardiac tumor in infant and children. Although the tumor is benign histologically, it may cause severe cardiac dysfunction and sudden death. A 30-day-old neonate with a huge intramural fibroma involving the posterolateral wall of the left ventricle underwent it`s partial resection under extracorporeal circulation on April 1992.

  • PDF

A Case of Congenital Epiglottic Cyst in Neonate (신생아에서 발생한 선천성 후두개 낭종 1례)

  • Seo, Deok-Jung;Lee, Joon-Kyoo
    • Korean Journal of Bronchoesophagology
    • /
    • v.13 no.2
    • /
    • pp.65-67
    • /
    • 2007
  • Congenital epiglottic cyst is rare cause of stridor in neonate and if managed inadequately, disaster such as death can occur. Diagnosis of congenital epiglottic cyst includes imaging studies and endoscopy. Fiberoptic or rigid endoscopic examination excludes other causes of stridor in neonate. Complete excision of cyst is treatment of choice under suspension laryngoscopic guidance. Here, we report a case of congenital epiglottic cyst and concomitant laryngomalacia presenting with seizure and respiratory difficulty in neonate with a review of literature.

  • PDF

Spontaneous Perforation of Meckel's Diverticulum in a Neonate (멕켈 게실 천공에 의한 신생아 복막염 1례)

  • Kim, Dong Won;Kim, Seung Sin;Park, Jae Ock;Lee, Do Sang
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.119-123
    • /
    • 2004
  • Meckel's diverticulum is the most common malformation of gastrointestinal tract. Symptoms of Meckel's diverticulum usually arise within 2 years of life. The most common presentations include hemorrhage, perforation, diverticulitis and intestinal obstruction. Perforation of the Meckel's diverticulum in a neonate is uncommon but life threatening condition. We describe the first case of perforation of Meckel's diverticulum in a 1-day-old neonate who presented with abdominal distension without hemorrhage.

  • PDF