• Title/Summary/Keyword: Neighboring tape′s AC current

Search Result 3, Processing Time 0.019 seconds

Effect of the Neighboring Tape′s AC Currents on Transport Current Loss of a Bi-2223 Tape (인접 교류전류가 Bi-2223테이프의 통전손실에 미치는 영향)

  • 류경우;최병주
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.251-256
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current simultaneously. AC loss taking into account such real applications is a crucial issue for power applications fo the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1./5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured trasprot losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents.The trasport losses do not depend on the frequency of the neighboring tape's AC currents but is arrangements in the range of small current especially.

  • PDF

AC loss analysis and experimental evaluation of a high temperature superconductor (고온초전도선재의 교류손실 해석 및 실험)

  • Ryu, Kyung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

Effect of the Neighboring Tape's AC Currents on Transport Current Loss of a HTS tape (인접전류가 고온 초전도테이프의 통전손실에 미치는 영향)

  • Park, Kwon-Bae;Ryu, Kyung-Woo;Choi, Byung-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.603-604
    • /
    • 2000
  • Bi-2223 테이프는 송전케이블과 같은 저 자장 전력시스템의 응용에 가장 유망한 선재로 알려져 있다. 송전케이블에 교류 전류가 인가되면 인접한 테이프에 의해서 발생되는 자계는 통전손실에 영향을 미치게 된다. 이와 같은 실제 송전케이블의 응용 측면을 고려하여 좌측 및 상부인접전류가 통전손실에 미치는 영향에 대하여 조사하였다. Bi-2223 테이프의 통전손실은 교류 인접전류가 증가함에 따라서 급격하게 증가하는 반면, 직류 인접전류의 영향은 무시 가능한 정도로 작았으며, 인접전류가 큰 경우는 테이프의 배열에 무관한 반면 작은 경우에는 상부배열인 경우의 영향이 큼을 알 수 있었다. 또한 Bi-2223 테이프의 통전손실은 교류 인접전류의 주파수에 무관함을 알 수 있었다.

  • PDF