• Title/Summary/Keyword: Negative temperature coefficient

Search Result 245, Processing Time 0.041 seconds

Performance of CMIP5 Models for the Relationship between Variabilities of the North Pacific Storm Track and East Asian Winter Monsoon (북태평양 스톰트랙 활동과 동아시아 겨울 몬순의 상관성에 관한 CMIP5 모델의 모의 성능)

  • Yoon, Jae-Seung;Chung, Il-Ung;Shin, Sang-Hye
    • Atmosphere
    • /
    • v.25 no.2
    • /
    • pp.295-308
    • /
    • 2015
  • Based on the CMIP5 historical simulation datasets, we assessed the performance of state-of-the-art climate models in respect to the relationship between interannual variabilities of the North Pacific synoptic eddy (NPSE) and East Asian winter monsoon (EAWM). Observation (ERA-Interim) shows a high negative correlation (-0.73) between the interannual variabilities of East Asian winter monsoon (EAWM) intensity and North Pacific synoptic eddy (NPSE) activity during the period of 1979~2005. Namely, a stronger (weaker) EAWM is related to a weaker (stronger) synoptic eddy activities over the North Pacific. This strong reverse relationship can be well explained by latitudinal distributions of the surface temperature anomalies over East Asian continent, which leads the variation of local baroclinicity and significantly weakens the baroclinic wave activities over the northern latitudes of $40^{\circ}N$. This feature is supported by the distribution of the meridional heat flux (${\overline{{\nu}^{\prime}{\theta}^{\prime}}}$) anomalies, which have negative (positive) values along the latitudes $40{\sim}50^{\circ}N$ for strong(weak) EAWM years. In this study, the historical simulations by 11 CMIP5 climate models (BCC-CSM1.1, CanESM2, GFDL-ESM2G, GFDL-ESM2M, HadGEM2-AO, HadGEM2-CC, IPSL-CM5A-LR, MPI-ESM-LR, MPI-ESM-MR, MRI-CGCM3, and NorESM1-M) are analyzed for DJF of 1979~2005. Correlation coefficient between the two phenomena is -0.59, which is comparable to that of observation. Model-to-model variation in this relationship is relatively large as the range of correlation coefficient is between -0.76 (HadGEM2-CC and HadGEM2-AO) and -0.33 (MRI-CGCM3). But, these reverse relationships are shown in all models without any exception. We found that the multi-model ensemble is qualitatively similar to the observation in reasoning (that is, latitudinal distribution of surface temperature anomalies, variation of local baroclinicity and meridional heat flux by synoptic eddies) of the reverse relationship. However, the uncertainty for weak EAWM is much larger than strong EAWM. In conclusion, we suggest that CMIP5 models as an ensemble have a good performance in the simulation of EAWM, NPSE, and their relationship.

A Study on PTC/NTC Behavior of Fluorinated Carbon Black-filled HDPE Matrix Compounds (불소처리된 카본블랙을 충전한 HDPE 기지 컴파운드의 PTC/NTC 특성에 관한 연구)

  • Soo-Jin Park;Su-Wan Song;Min-Kang Seo;Jae-Sup Shin;Kyuchul Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.147-154
    • /
    • 2003
  • In this study, the fluorinated carbon blacks(CB) were used to reduce the negative temperature coefficient (NTC) phenomenon of the CB-filled high density polyethylene(HDPE) compounds in the fluorination pressure of 0.1-0.4 MPa. The changes in surface properties of the CB were investigated by using FT-IR, XPS and contact angle measurements. From the FT-IR results, the fluorinated CB showed the C-F absorption peak at 1400-1000 cm$^{-1}$ and the peak intensity was increased with increasing the fluorination pressure. Also, the analysis of XPS spectra of the fluorinated CB indicated that fluorine content was increased with increasing the fluorination pressure. Meanwhile, the surface free energy of the fluorinated CB was decreased with increasing the fluorination pressure. Consequently, the increase of fluorine contents on CB made a disappearance of NTC behaviors of CB/HDPE compounds, which was probably due to the reduction of CB reaggregation after melting point of the HDPE, resulting from decreasing the surface free energy of CB particles.

Relationship assessment among land use and land cover and land surface temperature over downtown and suburban areas in Yangon City, Myanmar

  • Yee, Khin Mar;Ahn, Hoyong;Shin, Dongyoon;Choi, Chuluong
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.4
    • /
    • pp.353-364
    • /
    • 2016
  • Yangon city is experienced a rapid urban expansion over the last two decades due to accelerate with the socioeconomic development. This research work studied an investigation into the application of the integration of the Remote Sensing (RS) and Geographic Information System (GIS) for observing Land Use and Land Cover (LULC) patterns and evaluate its impact on Land Surface Temperature (LST) of the downtown, suburban 1 and suburban 2 of Yangon city. The main purpose of this paper was to examine and analyze the variation of the spatial distribution property of the LULC of urban spatial information related with the LST and Normalized Difference Vegetation Index (NDVI) using RS and GIS. This paper was observed on image processing of LULC classification, LST and NDVI were extracted from Landsat 8 Operational Land Imager (OLI) image data. Then, LULC pattern was linked with the variation of LST data of the Yangon area for the further connection of the correlation between surface temperature and urban structure. As a result, NDVI values were used to examine the relation between thermal behavior and condition of land cover categories. The spatial distribution of LST has been found mixed pattern and higher LST was located with the scatter pattern, which was related to certain LULC types within downtown, suburban 1 and 2. The result of this paper, LST and NDVI analysis exhibited a strong negative correlation without water bodies for all three portions of Yangon area. The strongest coefficient correlation was found downtown area (-0.8707) and followed suburban 1 (-0.7526) and suburban 2(-0.6923).

Correlation and Comparison Between $Yin$-Deficiency Questionnaire Score and Biofunctional signals (음허와 생체신호의 상관성 및 비교 연구)

  • Yoo, Seung-Yeon;Lee, Jin-Moo;Park, Young-Jae;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.68-78
    • /
    • 2012
  • Objectives: The purpose of this study was to analyze the relationship between Yin-deficiency questionnaire score and various biofunctional signals in women. Methods: A retrospective chart review was performed on charts of 195 patients who visited Gangdong Kyung Hee Hospital between April 1st and September 30th, 2011. The subjects were categorized into two groups, a low Yin-deficiency group (n=118) and a high Yin-deficiency group (n=77). The authors analyzed the correlation between Yin-deficiency questionnaire score and biofunctional signals by Pearson's correlation coefficient test and the difference in biofunctional signals between the two groups by independent samples t-test using SPSS for windows. Results: 1. Negative correlations were observed between the temperature difference of back-humerus, standard deviation of all R-R intervals (SDNN), total power (TP), low frequency (LF), high frequency (HF) on heart rate variability parameters, and Yin-deficiency questionnaire score. A positive correlation was observed between the temperature difference of knee-humerus and Yin-deficiency questionnaire score. 2. The temperature difference of back-humerus in the high Yin-deficiency group was significantly higher than that in the low Yin-deficiency group. The temperature difference of knee-humerus, height, waist-hip ratio, SDNN, TP, LF, and HF of the high Yin-deficiency group were significantly lower than those of the low Yin-deficiency group. Conclusions: The results of this study suggest that the comprehensive diagnosis of Yin-deficiency and biofunctional signals is useful.

Three-D core multiphysics for simulating passively autonomous power maneuvering in soluble-boron-free SMR with helical steam generator

  • Abdelhameed, Ahmed Amin E.;Chaudri, Khurrum Saleem;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2699-2708
    • /
    • 2020
  • Helical-coil steam generator (HCSG) technology is a major design candidate for small modular reactors due to its compactness and capability to produce superheated steam with high generation efficiency. In this paper, we investigate the feasibility of the passively autonomous power maneuvering by coupling the 3-D transient multi-physics of a soluble-boron-free (SBF) core with a time-dependent HCSG model. The predictor corrector quasi-static method was used to reduce the cost of the transient 3-D neutronic solution. In the numerical system simulations, the feedwater flow rate to the secondary of the HCSGs is adjusted to extract the demanded power from the primary loop. This varies the coolant temperature at the inlet of the SBF core, which governs the passively autonomous power maneuvering due to the strongly negative coolant reactivity feedback. Here, we simulate a 100-50-100 load-follow operation with a 5%/minute power ramping speed to investigate the feasibility of the passively autonomous load-follow in a 450 MWth SBF PWR. In addition, the passively autonomous frequency control operation is investigated. The various system models are coupled, and they are solved by an in-house Fortran-95 code. The results of this work demonstrate constant steam temperature in the secondary side and limited variation of the primary coolant temperature. Meanwhile, the variations of the core axial shape index and the core power peaking are sufficiently small.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Preparation of Bismuth Telluride Thin Films using RF magnetron sputtering and Study on Their Thermoelectric Properties (RF 마그네트론 스퍼터링을 이용한 Bismuth Telluride 박막의 제조와 그 열전 특성 연구)

  • Kim, Dong-Ho;Lee, Gun-Hwan
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.215-221
    • /
    • 2005
  • Thermoelectric bismuth telluride thin films were prepared on $SiO_{2}$/Si substrate with co-sputtering of bismuth and tellurium targets. The effects of deposition temperature on surface morphology, crystallinity and electrical transport properties were investigated. Hexagonal crystallites were clearly visible at the surface of films deposited above $290 ^{\circ}C$. Change of dominant phase from rhombohedral $Bi_2Te_3$ to hexagonal BiTe was confirmed with X-ray diffraction analysis. The deviation from stoichiometric composition at high deposition temperature resulted in the change of structural and electrical characteristics. Seebeck coefficients of all samples have negative value, indicating the prepared $Bi_XTe_Y$ films are n-type thermoelectric. Optimum of Seebeck coefficient and power factor were obtained at the deposition temperature of $225 \^{circ}$C (about -55 $\mu$V/K and $3\times10^{-4}$ W/$k^{2}$m, respectively). Deterioration of thermoelectric properties at higher temperature.

Structural and Electrical Properties of La0.7Sr0.3-xMgxMnO3 Ceramics with MgO Content (MgO 첨가에 따른 La0.7Sr0.3-xMgxMnO3 세라믹스의 구조적, 전기적 특성)

  • Hyun-Tae Kim;Jeong-Eun Lim;Byeong-Jun Park;Sam-Haeng Yi;Myung-Gyu Lee;Joo-Seok Park;Young-Gon Kim;Sung-Gap Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.275-279
    • /
    • 2023
  • La0.7Sr0.3-xMgxMnO3 (LSMMO) (x=0.05~0.20) specimens are fabricated by a solid phase sintering method, and the sintering temperature and time are 1,300℃ and 2 hours, respectively. The dependence of the crystalline structure according to the amount of Mg2+ contents is not observed, and all specimens show a polycrystalline rhombohedral crystal structure, the X-ray diffraction (110) peaks move to the high angle side with increasing the amount of Mg2+ contents. LSMMO specimens exhibit a granule-shaped microstructure with an average grain size of 1 ㎛ or less. Resistivity gradually decrease as the amount of Mg2+ contents increased. And in the La0.7Sr0.1Mg0.2MnO3 specimen, resistivity and B25/65-value are 36.7 Ω-cm and 394 K at room temperature, respectively. LSMMO specimens show a variable-range hopping (VRH) electrical conduction mechanism, and the negative temperature of coefficient of resistance (NTCR) is approximately 0.37~0.38%/℃.

Properties of SiC-$ZrB_2$ Electroconductive Ceramic Composites by Spark Plasma Sintering (방전플라즈마 소결에 의한 SiC-$ZrB_2$ 도전성 세라믹 복합체 특성)

  • Shin, Yong-Deok;Ju, Jin-Young;Jo, Sung-Man;Lee, Jung-Hoon;Kim, Cheol-Ho;Lee, Hee-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1252_1253
    • /
    • 2009
  • The composites were fabricated by adding 0, 15, 20, 25[vol.%] Zirconium Diboride(hereafter, $ZrB_2$) powders as a second phase to Silicon Carbide(hereafter, SiC) matrix. The physical, mechanical and electrical properties of electroconductive SiC ceramic composites by spark plasma sintering(hereafter, SPS) were examined. Reactions between $\beta$-SiC and $ZrB_2$ were not observed in the XRD analysis The relative density of mono SiC, SiC+15[vol.%]$ZrB_2$, SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ composites are 90.97[%], 74.62[%], 77.99[%] and 72.61[%] respectively. The XRD phase analysis of the electroconductive SiC ceramic composites reveals high of SiC and $ZrB_2$ and low of ZrO2 phase. The electrical resistivity of mono SiC, SiC+15[vol.%]$ZrB_2$, SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ composites are $4.57{\times}10^{-1}$, $2.13{\times}10^{-1}$, $1.53{\times}10^{-1}$ and $6.37{\times}10^{-2}[{\Omega}{\cdot}cm]$ at room temperature, respectively. The electrical resistivity of mono SiC, SiC+15[vol.%]$ZrB_2$, SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ are Negative Temperature Coefficient Resistance(hereafter, NTCR) in temperature ranges from 25[$^{\circ}C$] to 100[$^{\circ}C$]. It is convinced that SiC+20[vol.%]$ZrB_2$ composite by SPS can be applied for heater above 1000[$^{\circ}C$].

  • PDF

Degree of Restraint(DOR) of Longitudinal Steel at Continuously Reinforced Concrete Pavement(CRCP) Against Environmental Loadings (환경하중에 의한 연속철근콘크리트(CRCP) 종방향 철근의 구속정도)

  • Nam, Jeong-Hee;Ahn, Sang Hyeok
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.95-104
    • /
    • 2014
  • PURPOSES : The purpose of this study is to evaluate the degree of restraint (DOR) of longitudinal steel at continuously reinforced concrete pavement (CRCP) against environmental loadings. METHODS : To measure the longitudinal steel strain, 3-electrical resistance and self-temperature compensation gauges were installed to CRCP test section (thickness = 250mm, steel ratio = 0.7%) and continuously measured 10 min. intervals during 259 days. In order to properly analyze the steel strains first, temperature compensation process has been conducted. Secondly, measured steel strains were divided into 12 phases with different events such as before paving, during concrete hardening, and after first cracking, etc. RESULTS : Thermal strain rate (TSR) concept is defined as the linear strain variations with temperature changes and restraints rate of longitudinal steel against environmental loadings (especially thermal loading) with different cases is defined as degree of restraint(DOR). New concept of DOR could be indirect indicator of crack width behaviors of CRCP. CONCLUSIONS : Before paving, DOR of longitudinal steel is almost same at the coefficient of thermal expansion of steel ($12.44m/m/^{\circ}C$) because of no restraint boundary condition. After concrete pouring, DOR is gradually changed into -1 due to concrete stiffness developing with hydration. After first cracking at crack induced area, values of DOR are around -3~-5. The negative DOR stands for the crack width behavior instead of steel strain behavior. During winter season, DOR reached to -5.77 as the highest, but spring this values gradually reduced as -1.7 as the lowest. Based on this observation, we can presume crack width decreased over time within the time frame of this study. This finding is not consistent with the current theory on crack width variations over time, so further study is necessary to identify the causes of crack width reducing. One of the reasons could be related to concrete stress re-distribution and stress relaxation.