• Title/Summary/Keyword: Negative resonance

Search Result 312, Processing Time 0.024 seconds

Monitoring of Commercial Red Pepper Powders for Their Irradiation Status (물리적 확인시험법을 이용한 시판 유통 중인 고춧가루의 방사선 조사여부 판별 모니터링)

  • Jeong, Mi-Seon;Ahn, Jae-Jun;Akram, Kashif;Kim, Gui-Ran;Kim, Hyun-Ku;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.673-679
    • /
    • 2012
  • Ten commercially available red pepper powders were investigated using photostimulated-luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) analyses to confirm their irradiation status. The application of PSL, TL, and ESR analyses was also confirmed by in-house irradiation. In PSL-based screening, all samples gave negative photon counts (<700 PCs). The PSL calibration dose (1 kGy) showed a low sensitivity of 4 samples, while the others provided reliable screening results. TL glow curves demonstrated maximum peaks after $250^{\circ}C$ for the 6 samples; however 4 samples gave complex TL glow curves with maximum peaks in the range of $185-260^{\circ}C$ (radiation-specific), which could be the effect of an irradiated component in low concentration as the TL ratios of all samples were <0.1. Radiation-specific ESR features were absent in the all commercial samples. Variable irradiation detection properties were found; where the TL analysis showed the possible presence of an irradiated component in 4 samples requiring further monitoring and investigation.

Electrical Properties and Electromagnetic Shielding Effectiveness of Milled Carbon Fiber/Nylon Composites (분쇄형 탄소 섬유/나일론 복합재료의 전기적 성질과 전자파 차폐 효율)

  • 김창제;최형도;서광석;윤호규
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.201-209
    • /
    • 2003
  • DC and AC electrical conductivity and electromagnetic interference shielding effectiveness of milled carbon fiber/nylon composites were investigated with the kind of nylon matrix. Percolation transition at which the conductivity is sharply increased was observed at about 7 vol% of milled carbon fiber. Nylon 46 as a matrix was more effective to obtain high electrical conductivity than nylon 6, and the difference in conductivity was occurred by the treatment of coupling agent. Frequency dependence of AC conductivity could be explained by relaxation phenomenon at just below percolation and resonance phenomenon at 40 vol% of carbon fiber, respectively. Negative temperature coefficient phenomenon was found in all composites. Electromagnetic interference shielding effectiveness was increased with the concentration of carbon fiber. At a high conductivity region the return loss was more dominant to the total shielding effectiveness than the absorption loss.

Computer-Assisted Modified Mid-Sacrectomy for En Bloc Resection of Chordoma and Preservation of Bladder Function

  • Han, In-Ho;Seo, Young-Jun;Cho, Won-Ho;Choi, Byung-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.523-527
    • /
    • 2011
  • A 67-year-old woman presented for evaluation of severe coccygeal pain. The computed tomography scans and magnetic resonance imaging showed an asymmetric midline sacral tumor invading the right lower portion of S2. To preserve both S2 nerve roots and to obtain negative surgical margins, a modified mid-sacrectomy with an aid of a computed navigation system was performed. The sacral tumor was excised en bloc with negative tumor margins. Both S2 nerve roots were preserved and additional reconstruction was not necessary because of minimal resection of the sacroiliac joint. We report a case of a sacral chordoma which was excised en bloc with adequate surgical margins by a computer-assisted modified mid-sacrectomy. The computed navigation system may be a useful tool for tumor targeting and safe osteotomies in sacral tumor surgery via the posterior only approach.

Wideband ENG Zeroth-Order Resonant Antenna Having Mushroom Shape (버섯 형태를 갖는 광대역 ENG 영차 공진 안테나)

  • Chang, Woo-Cheol;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.997-1002
    • /
    • 2009
  • This Letter presents a wideband ENG(Epsilon Negative) ZOR(Zeroth-Order Resonant) antenna designed on a microstrip line. It has a mushroom structure and its size is only $7.65{\times}1.31{\times}2.37\;mm$(or $0.306{\times}0.053{\times}0.095\;{\lambda}_0$ at 12 GHz) owing to zeroth-order resonance. The design procedures with closed form solutions are provided using transmission line theory considering radiation loss. The measured antenna bandwidth is about 20.0 % at 9.2 GHz and antenna gain is 7.1 dBi despite the compact size.

비정질 탄소막 (a-C:H) 내에 존재하는 수소에 관한 연구

  • 박노길;박형국;손영호;정재인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.133-133
    • /
    • 1999
  • 비정질 탄소막 제조에 있어서 수소가 포함된 반응성 가스를 사용할 경우 제작된 탄소막 내부에는 수소가 포함되게 되며, 이러한 수소원자들은 막의 특성에 중요한 영향을 주는 것으로 알려져 있다. 따라서, 본 연구에서는 비정질 탄소막(a-C:H) 내부에 존재하는 수소가 탄소막의 특성에 미치는 영향을 알아보고, 막 내부에 포함된 수소의 함량과 공정조건 사이의 함수계를 조사함으로써 수소의 함량을 인위적으로 통제할 수 있는 가능성을 제시하고자 한다. 수소가 포함된 비정질 탄소막은 2.45 GHz의 전자기파를 사용하는 electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) 방법과 DC magnetron sputtering 법을 사용하여 제작하였다. 기판으로는 Si(001) wafer를 사용하였으며, 아세톤과 에탄올을 사용하여 표면의 유기성분을 제거하고, 진공챔버속에서 Ar 플라즈마를 발생시켜 sputter etching 방법으로 표면을 세척하였다. ECR-PECVD 방법에서는 반응가스로 메탄(CH4)과 수소(H2)의 혼합가스를 사용하였으며, 혼합가스의 비는 5~50% 범위내에서 변화를 주었다. 수소가스의 유량은 100SCCM으로 고정하였으며, 마이크로웨이브의 power는 360~900W였고, 기판에 가해준 negative DC bias 전압은 0~-500V이었다. DC magnetron sputtering 방법에서는 반응가스로 아세틸린(C2H2) 가스를 사용하였으며, 플라즈마 발생을 용이하게 하기 위해서 Ar 가스와 혼합하여 사용하였다. Ar 가스의 유량은 10SCCM으로 고정하였으며, 아세틸렌 가스의 유량은 5~20SCCM 범위내에서 주입하였다. 이때, 기판에 가해준 negative DC bias 전압은 0~-100V이었다. 제작된 탄소막의 수소 함량을 조사하기 위하여 Fourier Transform Infrared (FTIR) 분광법과 Elastic Recoil Detection Analysis (EFDA) 법을 사용하였으며, 증착율은 SEM 단면촬영과 a-step을 이용하여 측정하였고, 막의 경도는 Micro-Hardness Testing 법을 사용하여 측정하였다.

  • PDF

A Case of Poliomyelitis-like Syndrome with Typical Abnormalities in MRI (자기공명영상에서 전형적인 이상 소견을 보인 소아마비양 증후군 환자 1예)

  • Kim, Seok-Il;Koo, Ja-Seong;Yoon, Doo-Sang;Kim, Byung-Kun;Bae, Hee-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.56-59
    • /
    • 2002
  • A 28-year-old man presented with headache, fever, and myalgia. Subsequently, rapidly progressive quadriplegia with areflexia developed. CSF examination revealed moderate pleocytosis and protein elevation. MRI of brain and spinal cord showed hyperintense lesions on T2-weighted image at midbrain and ventral horns along the whole spinal cord. Serial serologic examinations of CSF for Epstein-Barr virus and cytomegalovirus were negative. Culture and neutralization tests of stool and CSF for enterovirus were negative. Although the etiologic pathogen was not identified, we diagnosed him as poliomyelitis-like syndrome by clinical features and findings of MRI.

  • PDF

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

The Characteristics of DC-shift in Hybrid Rocket (하이브리드 로켓에서의 DC-shift 발생 특성)

  • Kang, Dong-Hoon;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.456-466
    • /
    • 2010
  • Typical combustion instability such as DC-Shift found in the hybrid rocket motor is characterized by non-linearity. DC-Shift can occur in two different realizations. One is so-called a positive shift of measured DC voltage where the pressure increase suddenly. The other is a negative shift where the pressure drops abruptly. In the present work, specifically the negative DC-Shift was investigated to analyze the effect of oxidizer flow condition and the resonance between fundamental frequency and other ones, such as Helmholtz frequency, and acoustic frequency. Results show a peak frequency of several hundreds HZ shifts as combustion proceeds. A negative DC-shift was found as the result of phase cancellation between two dominant frequency, combustion frequency and flow related frequency. Still is it required to study further to identify the change of dominance of frequency during the combustion.

High Accuracy Mass Measurement Approach in the Identification of Phospholipids in Lipid Extracts: 7 T Fourier-transform Mass Spectrometry and MS/MS Validation

  • Yu, Seong-Hyun;Lee, Youn-Jin;Park, Soo-Jin;Lee, Ye-Won;Cho, Kun;Kim, Young-Hwan;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1170-1178
    • /
    • 2011
  • In the present study, the approach of high accuracy mass measurements for phospholipid identifications was evaluated using a 7 T ESI-FTMS/linear ion trap MS/MS. Experiments were carried out for porcine brain, bovine liver, and soybean total lipid extracts in both positive and negative ion modes. In total, 59, 55, and 18 phospholipid species were characterized in the positive ion mode for porcine brain, bovine liver, and soybean lipid extracts, respectively. Assigned lipid classes were PC, PE, PEt, PS, and SM. In the negative ion mode, PG, PS, PA, PE, and PI classes were observed. In the negative ion mode, for porcine brain, bovine liver, and soybean lipid extracts, 28, 34, and 29 species were characterized, respectively. Comparison of our results with those obtained by other groups using derivatization-LC-APCI MS and nano-RP-LC-MS/MS showed that our approach can characterize PC species as effectively as those methods could. In conclusion, we demonstrated that high accuracy mass measurements of total lipid extracts using a high resolution FTMS, particularly, 7T FTMS, plus ion-trap MS/MS are very useful in profiling lipid compositions in biological samples.

Diagnostic Performance of Breast MRI in the Evaluation of Contralateral Breast in Patients with Diagnosed Breast Cancer

  • Saeed, Shaista Afzal;Masroor, Imrana;Beg, Madiha;Idrees, Romana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7607-7612
    • /
    • 2015
  • Aims: The purpose of our study was to evaluate the diagnostic performance of breast magnetic resonance imaging (MRI) in the evaluation of contralateral breast in patients with diagnosed breast cancer. A secondary objective was to determine accuracy of breast MRI in diagnosing multi-focal and multicentric lesions in the ipsilateral breast. Materials and Methods: Using a non-probability convenience sampling technique, patients with histopathologically diagnosed breast cancer with MRI of breast performed to exclude additional lesions were included. MRI findings were correlated with histopathology. In addition, follow-up imaging with mammography and ultrasound was also assessed for establishing stability of negative findings and for the detected of benign lesions. Results: Out of 157 MRI breast conducted during the period of 2008 to 2013, 49 were performed for patients with diagnosed breast cancer. The sample comprised of all females with mean age $50.7{\pm}11.0years$. The patient follow-up imaging was available for a period of 2-5 years. The sensitivity, specificity, and positive and negative predictive values of MRI in the detection of multifocal/multicenteric lesions was 85.7%, 88.8%, 60% and 96.6% respectively and for the detection of lesions in the contralateral breast were 100%, 97%, 83.3% and 100% respectively. Conclusions: Our study highlights the diagnostic performance and the added value of MRI in the detection of multifocal/multicenteric and contralateral malignant lesions. In patients with diagnosed breast cancer having dense breast parenchyma and with infiltrating lobular carcinoma as the index lesion MRI is particularly useful with excellent negative predictive value in the exclusion of additional malignant foci in the ipsilateral and contralateral breasts.