• 제목/요약/키워드: Negative Pressure Room

검색결과 48건 처리시간 0.03초

관류홴의 설계인자 변화에 따른 리어가이더의 표면압력 특성에 관한 실험적 연구 (Experimental Study on the Surface Pressure Characteristics of a Rear-Guider for the Various Design Factors of a Cross-Flow Fan)

  • 김장권
    • 동력기계공학회지
    • /
    • 제9권3호
    • /
    • pp.50-57
    • /
    • 2005
  • A cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The purpose of this paper is to investigate the effects of a rear-guider and a stabilizer on the surface pressure of a rear-guider in an indoor room air-conditioner using a cross-flow fan. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. The operating condition of a cross-flow fan was controlled by changing the static pressure and flowrate using a fan tester. All surface pressures of a rear-guider are differently distributed according to the stabilizer setup angle, and show a zero value in the flow coefficient, ${\Phi}{\fallingdotseq}0.5$ only of a stabilizer setup angle, $45^{\circ}$. Especially, they show a big negative value in the expansion angle larger than $34^{\circ}$ regardless of a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle. On the other hand, surface pressures for various stabilizer cutoff clearances are better than those for various rear-guider clearances.

  • PDF

COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험 (Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk)

  • 진광남;남보다;신재민;황성호
    • 대한영상의학회지
    • /
    • 제84권4호
    • /
    • pp.891-899
    • /
    • 2023
  • 목적 급성호흡기질환인 코로나바이러스감염증-19 (coronavirus disease 2019; 이하 COVID-19) 환자를 대상으로 한 음압격리들것(negative presurre isolation stretcher; 이하 NPIS)을 이용한 흉부 전산화단층촬영(이하 CT) 방식에 대해 전문의들의 경험과 의견을 확인하고자 하였다. 대상과 방법 격리입원 중인 COVID-19 환자에게 NPIS를 이용한 흉부 CT 검사를 시행했던 9개 의료기관 소속 27명의 전문의들을 대상으로 1) 조영증강 흉부 CT가 필요한 경우, 2) NPIS를 이용한 흉부 CT의 영상품질, 그리고 3) CT 조영제주사를 위한 NPIS 개방과 CT 검사실의 오염을 주제로 설문조사를 진행하였다 결과 조사대상인 9개의 의료기관들은 기관당 한 해 평균 116건의 COVID-19관련 흉부 CT 검사를 NPIS와 함께 진행했으며. 전체 검사 건수 중 평균 24건(21%)이 조영증강 흉부 CT였다. 설문에 참여한 호흡기내과 전문의 9명 중 5명(56%)은 환자의 혈중 D-dimer 이상이 확인되면 조영증강 CT가 필요하다고 의견을 밝혔다. 한편 영상의학과 전문의 9명 모두는 NPIS로 인한 흉부 CT 영상의 품질은 폐렴 또는 폐혈전 진단이 가능한 수준이라 답하였다. 또한 감염내과 전문의 9명 중 5명(56%)은 NPIS의 개방으로 인한 CT 검사실의 이차감염은 소독을 통해 예방할 수 있는 수준으로 생각하고 있었다. 결론 격리입원 중인 COVID-19 환자에서 NPIS와 함께 흉부 CT를 진행하더라도 CT의 품질은 진단이 가능한 수준이며 NPIS가 CT 검사실 내에서 잠시 개방되더라도 CT 검사실의 감염확산 위험은 높지 않은 것으로 전문의들은 인식하고 있었다.

Transition temperatures and upper critical fields of NbN thin films fabricated at room temperature

  • Hwang, T.J.;Kim, D.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.9-12
    • /
    • 2015
  • NbN thin films were deposited on thermally oxidized Si substrate at room temperature by using reactive magnetron sputtering in an $Ar-N_2$ gas mixture. Total sputtering gas pressure was fixed while varying $N_2$ flow rate from 1.4 sccm to 2.9 sccm. X-ray diffraction pattern analysis revealed dominant NbN(200) orientation in the low $N_2$ flow rate but emerging of (111) orientation with diminishing (200) orientation at higher flow rate. The dependences of the superconducting properties on the $N_2$ gas flow rate were investigated. All the NbN thin films showed a small negative temperature coefficient of resistance with resistivity ratio between 300 K and 20 K in the range from 0.98 to 0.89 as the $N_2$ flow rate is increased. Transition temperature showed non-monotonic dependence on $N_2$ flow rate reaching as high as 11.12 K determined by the mid-point temperature of the transition with transition width of 0.3 K. On the other hand, the upper critical field showed roughly linear increase with $N_2$ flow rate up to 2.7 sccm. The highest upper critical field extrapolated to 0 K was 17.4 T with corresponding coherence length of 4.3 nm. Our results are discussed with the granular nature of NbN thin films.

COVID-19 중환자를 돌보는 간호사들의 경험 (Nurses' experiences of caring for severe COVID-19 patients)

  • 강명미;박예나;박성영;김주현
    • 중환자간호학회지
    • /
    • 제15권2호
    • /
    • pp.14-26
    • /
    • 2022
  • Purpose : This study aimed to understand and describe the nurses' experiences caring for severe COVID-19 patients at isolation room with negative pressure in South Korea. Methods : Data were collected through individual in-depth interviews from February 16 to March 31, 2021 with 11 nurses who had been caring for severe COVID-19 patients at isolation room. Verbatim transcripts were analyzed according to Colaizzi's phenomenological analysis. Results : As a result, 5 theme clusters were extracted about nurses' experiences. The 5 theme clusters, "Adapting to unexpected adversity", "Accepting unresonable and heavy work", "Dulness and disconnection from the outside world", "Changing in perception of new infectious diseases", and "Pathetic isolated patients" emerged. Conclusion : The results of this study provided a deeper understanding of nurses struggling to care for COVID-19 severe patients. This study is expected to be useful in providing basic evidence for improving intensive care practices and for preparing policies in other infection disease situations.

압연이 Ni-MH 2차전지용 금속수소화물 전극의 충·방전 특성에 미치는 영향 (The Effect of Rolling on the Charge-Discharge Characteristic of Metal Hydride Electrode for Ni-MH Secondary Battery)

  • 박원;장상민;최승준;노학;최전;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.165-171
    • /
    • 1996
  • The effect of rolling on the charge-discharge property was studied for metal hydride negative electrode. $(LM)Ni_{3.6}Al_{0.4}Co_{0.7}Mn_{0.3}$(pleateau pressure : below 1 atm at room temperature, volume expansion : 9%, entalpy : $8.7kcal/molH_2$) alloy was prepared by arc melting, and then it was coated with various copper weight percent. The copper coated alloys were then rolled with the different reduction ratio. From the results, it was found that the maximum discharge capacity increased with increasing reduction ratio, and 15wt% copper coated sample shows the highest discharge capacity, 324mAh/g, after rolling with 30% reduction ratio. In view of cycle life for the negative electrode, the 15wt% copper coated electrode which was rolled with 13% reduction ratio showed the longest cycle life compared with other electrodes.

  • PDF

비정질 하프늄인듐징크옥사이드 산화물 반도체의 공정 파워에 따른 트랜지스터의 전기적 특성 연구 (Study on the Electrical Properties of Amorphous HfInZnO TFTs Depending on Sputtering Power)

  • 유동윤;정유진;김도형;주병권;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제24권8호
    • /
    • pp.674-677
    • /
    • 2011
  • The dependency of sputtering power on the electrical performances in amorphous HIZO-TFT (hafnium-indium-zinc-oxide thin film transistors) has been investigated. The HIZO channel layers were prepared by using radio frequency (RF) magnetron sputtering method with different sputtering power at room temperature. TOF-SIMS (time of flight secondary ion mass spectrometry) was performed to confirm doping of hafnium atom in IZO film. The field effect mobility (${\mu}FE$) increased and threshold voltage ($V_{th}$) shifted to negative direction with increasing sputtering power. This result can be attributed to the high energy particles knocking-out oxygen atoms. As a result, oxygen vacancies generated in HIZO channel layer with increasing sputtering power resulted in negative shift in Vth and increase in on-current.

SiC-$TiB_2$ 전도성(電導性) 복합체(複合體)의 특성(特性)에 미치는 가압(加壓)의 영향(影響) (Effect of Pressure on Properties of the SiC-$TiB_2$ Electroconductive Ceramic Composites)

  • 신용덕;서재호;주진영;고태헌;이정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1228-1229
    • /
    • 2008
  • The composites were fabricated 61[vol.%] ${\beta}$-SiC and 39[vol.%] $TiB_2$ powders with the liquid forming additives of 12[wt%] $Al_2O_3+Y_2O_3$ as a sintering aid by pressure or pressureless annealing at 1,650[$^{\circ}C$] for 4 hours. Reactions between SiC and transition metal $TiB_2$ were not observed in the microstructure and the phase analysis of the SiC-$TiB_2$ electroconductive ceramic composites. Phase analysis of SiC-$TiB_2$ composites by XRD revealed mostly of ${\alpha}$-SiC(6H), $TiB_2$, and In Situ $YAG(Al_5Y_3O_{12})$. The relative density, the flexural strength and the Young's modulus showed the highest value of 88.32[%], 136.43[MPa] and 52.82[GPa] for pressure annealed SiC-$TiB_2$ composites at room temperature. The electrical resistivity showed the lowest value of 0.0162[${\Omega}{\cdot}cm$] for pressure annealed SiC-$TiB_2$ composite at 25[$^{\circ}C$]. The electrical resistivity of the pressure annealed SiC-$TiB_2$ composite was positive temperature coefficient resistance (PTCR) but the electrical resistivity of the pressureless annealed SiC-$TiB_2$ composites was negative temperature coefficient resistance(NTCR) in the temperature ranges from 25[$^{\circ}C$] to 700[$^{\circ}C$].

  • PDF

여성들의 찜질방 이용 현상에 관한 일상 생활 기술적 연구

  • 전정자;유은광
    • 대한간호학회지
    • /
    • 제27권4호
    • /
    • pp.961-974
    • /
    • 1997
  • The ZZimzilbang is a room where many women eagerly go due to the special meaning women give to it related to their health. It is a different type of sauna room which maintains low degree of temperature, consisting of an Ondol room(Korean under-floor heating system, hypocaust) built with mineral stone radiating ultrared rays. Even though many women mention that they utilize it for health, there is no precise evidence of the effects on their health. This ethnographic study sought to define the phenomenon from the perspective of the women who experienced the ZZimzilbang. A convenience sample of 27 women was interviewed during a 15 month period from December 1995 to July 1997 in 12 ZZimzilbangs located in Seoul, Korea. The mean ages of the women 57.3 years ; seventeen women were housekeeper and only eight women had job : twenty women were married and three women among them were widows. The main reasons women patronize the place are : for mitigation and healing of physical signs and symptoms : composure ; safe lodging and boarding : control of outward appearance : control of health ; meeting and fellowship with friends : and custom. The outcomes of the utilization of the place were : mitigation of physical signs and symptoms : psychological tranquility : cosmetic and diet ; good use of spare time : and utilization of services provided there. Most women who visited ZZimzilbang for relief of physical signs and symptoms strongly mentioned a correlation to inadequate Sanhujori, the traditional postpartal and postabortal care for woman. Some of specific kinds of services provided in that place were alternative therapy such as acupuncture, negative cupping, finger-pressure, mugwort steam and various kinds of massage including massage of blood vessels that are influenced by Oriental medicine ; health education of breathing such as abdominal breathing or Danjeon(단전호흡) : and selling of many things including health foods, drugs for osteoporosis, and eutrophics. This study suggests that professional caregivers should further study this phenomenon for the development of adequate care of women with a resulting important in their quality of life.

  • PDF

공기 청정지역(Class 100 이하)에 적합한 정전기 제거장치의 개발 및 특성에 관한 연구(I) - LCD 제조 공정을 중심으로 - (A Study for Development and Characteristics of Electrostatic Eliminator Suitable for the Super Clean Room Less than Class 100(I))

  • 정용철;박훈규;이동훈
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.60-65
    • /
    • 2006
  • It is a well known fact that LCD is a central part of the IT industry which is important in the present and the future. But the biggest problem of LCD manufacturing is maintaining a cleaning room environment and administration. Therefore the purpose of this study is to first, prevent the yield depreciation and damage of products, and second, protect the worker ftom accidental electrostatic discharge during LCD manufacture. The soft x-ray ionizer is a type of electrostatic reducer device. It protects against electrostatic discharge in the cleaning room environment and is a necessary environmental factor during LCD production. The positive aspects of the soft x-ray are its shorter time and wider angle of exposure. But the negative aspect of the soft x-ray is its need for several shielding of protection from the harmful x-ray exposure. On this study, the development of the Air Nozzle-type ionizer to amend and refine some problems. For example, examined the electrostatic reduce device of a soft x-ray type and discovered the ion did not go inside well. also workers to be free from danger. An Air Nozzle-type ionizer is comprised of soft x-ray radiation and ionized air production. Air is injected through the nozzle after being ionized from radiation. It supplies air keeping the same pressure into the end foundation of ion production. The soft x-ray is the structure which radiates ionized air through the nozzle (21 holes) having micro holes of the ionizable radiation after ionizing the inside air by the ion production. A worker does not need a cover to protect against x-rays and the Air Nozzle-type ionizer is easy to set up and is more effective at eliminating electrostatic.

중증 호흡기 감염병 진료를 고려한 음압격리병동부의 건축계획 (A Development of Design Guidelines for the Negative Pressured Isolation Units Controlling Severe Respiratory Infectious Disease)

  • 권순정;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권3호
    • /
    • pp.45-56
    • /
    • 2016
  • Purpose: The MERS(Middle East Respiratory Syndrome) outbreaks in Korea highlighted dramatically the failings of traditional hospital environment for controlling or preventing infections among both patients and healthcare workers. MERS is transmitted by droplets that can be airborne over a limited area. The point should be emphasized that MERS in South Korea was predominantly a hospital-acquired (not a community-acquired) infection, because approximately 93% of MERS cases were resulted from exposure in hospital settings. This paper tries to suggest the design guidelines of negative pressured isolation ward for the sake of proper control of severe respiratory infectious diseases. Methods: Literature survey on the design guideline and regulations of airborne infection wards in Korea, Europe U.K. and CDC of U.S. have been carries out. 4 special infection wards in Hongkong, Germany, Japan and Korea have been surveyed in order to make the best use of the experiences related to facility design and operations. Results: Operating system influencing the facility design, space organizations of infectious ward including required space and zoning, and circulations of patients, staffs and materials are proposed. Implications: The results of this paper can be the basic data for the design of the airborne infection ward and relevant regulations. Afterwards in-depth study such as the development of space standards for the single bedroom, locker room and so on could be explored.