• Title/Summary/Keyword: Needle imaging

Search Result 141, Processing Time 0.022 seconds

Effect of epidural corticosteroid injection on magnetic resonance imaging findings

  • Kim, Min Soo;Jeong, Tae Yoon;Cheong, Yu Seon;Jeon, Young Wook;Lim, So Young;Kang, Seong Sik;Kim, In Nam;Chang, Tsong Bin;Seong, Hyun Ho;Hwang, Byeong Mun
    • The Korean Journal of Pain
    • /
    • v.30 no.4
    • /
    • pp.281-286
    • /
    • 2017
  • Background: Magnetic resonance imaging (MRI) of the spine is the preferred diagnostic tool for pathologic conditions affecting the spine. However, in patients receiving epidural corticosteroid injection (ESI) for treatment of spinal diseases, there is a possibility of misreading of MR images because of air or fluid in the epidural space after the injection. Therefore, we defined the characteristics of abnormal changes in MRI findings following an ESI in patients with low back pain. Methods: We reviewed the medical records of 133 patients who underwent MRI of the lumbar spine within 7 days after ESI between 2006 and 2015. All patients were administered an ESI using a 22-gauge Tuohy needle at the lumbar spine through the interlaminar approach. The epidural space was identified by the loss of resistance technique with air. Results: The incidences of abnormal changes in MRI findings because of ESI were 54%, 31%, and 25% in patients who underwent MRI at approximately 24 h, and 2 and 3 days after ESI, respectively. Abnormal MRI findings included epidural air or fluid, needle tracks, and soft tissue changes. Epidural air, the most frequent abnormal finding (82%), was observed in 41% of patients who underwent MRI within 3 days after injection. Abnormal findings due to an ESI were not observed in MR images acquired 4 days after ESI or later. Conclusions: Pain physicians should consider the possibility of abnormal findings in MR images acquired after epidural injection using the interlaminar approach and the loss of resistance technique with air at the lumbar spine.

Imaging Features of the Intra-abdominal Granulomas in Two Cases (두 케이스에서 복강내 육아종의 영상학적 특징)

  • Choi, Mi-Hyun;Chang, Jin-Hwa;Lee, Hye-Yeon;Kim, Jun-Young;Kim, Wan-Hee;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.302-306
    • /
    • 2010
  • One dog and a cat with a history of diarrhea, anorexia and depression were referred. They showed normal laboratory examination results. Radiographic findings included a mid abdominal mass with ill-defined margin and serosal detail loss of peritoneal space. On abdominal ultrasonography, the round mass with heterogenous parenchymal echogenicty with irregular contour was found. It revealed as inflammation through ultrasound guide fine needle aspiration. After surgical removal of the masses in both cases, the clinical signs were resolved and focal pyogranuloma was confirmed through histopathologic examinations.

Spectrum of Cytological Findings in Fine Needle Aspiration Cytology of Breast Lumps with Histopathology Correlation: Experience in a Tertiary Care Rural Hospital in India

  • Kochhar, Ajay Kumar;Jindal, Umesh;Singh, Karandeep
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7257-7260
    • /
    • 2013
  • To determine the pattern of disease in patients presenting with breast lumps and to determine the sensitivity and specificity of fine needle aspiration cytology of benign and malignant diseases as a diagnostic tool by correlating with histopathology findings. This retrospective study was carried out in the Department of Pathology, Maharaja Agrasen Medical College, Agroha, from Jan 2008 to April 2012. Fine needle aspiration cytology was performed on 370 cases and out of these 52 cases were received in the Department for histopathological examination. Fibroadenoma was the most common disease encountered, in 88 (24%), with a peak incidence in second and third decade of life. Fibrocystic disease was second, being common in the third and fourth decades of life. Peak incidences of duct ectasia, granulomatous and tubercular mastitis were seen in the third decade. Gynaecomastia showed two peak incidences in second and sixth decades of life. Out of total 370 cases undergoing fine needle aspiration, benign cases were 316 (85.4%), malignant and suspicious were 54 (14.6%) and 10 (2.70%) respectively. Out of total 22 histological confirmed malignant lesions 19 were interpreted as malignant cytologically while two as suspicious and one as benign. All thirty histologically confirmed benign cases were diagnosed as benign cytologically. The sensitivity, specificity, positive and negative predictive values were 98%, 100%, 100% and 96.4% respectively. FNA cytology is highly accurate for diagnosis of breast masses. However, the clinician should correlate FNA cytological results with physical examination and imaging findings to prevent false negative and false positive events and to obtain optimal management of their patients.

Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

  • Farshid, Gelareh;Sullivan, Thomas;Jones, Simeon;Roder, David
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10665-10673
    • /
    • 2015
  • Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia (BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous data regarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services, from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rates were 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery 97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied, 46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in 21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imaging After FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was 0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% for core biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcifications are being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positive diagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB, 86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSA services are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps in the present accreditation standards require further consideration.

Clinical and radiological outcomes of ultrasound-guided barbotage using a spinal needle and subacromial steroid injection for calcific tendinitis of the shoulder

  • Lee, Jun Pyo;Kim, Doo Sup;Han, Jin Young;Baik, Seung Hoon;Kwak, Ji Woong;Kim, Sung Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.140-144
    • /
    • 2022
  • Background: Ultrasound (US)-guided techniques reported for the treatment of calcific tendinitis have mostly demonstrated good results. This study investigates the effect of US-guided barbotage using a spinal needle in patients with calcific tendinitis of the shoulder. Methods: Thirty-six patients with calcific tendinitis of the shoulder treated by US-guided barbotage with a spinal needle and subacromial steroid injection were included in the study. We evaluated clinical outcomes based on American Shoulder and Elbow Surgeons (ASES) score, Constant score, and visual analog scale (VAS) for pain score. Radiological outcomes were assessed by X-ray imaging at each visit. Results: Our results showed that US-guided barbotage and subacromial steroid injection produced good clinical and radiological outcomes in patients with calcific tendinitis of the shoulder. Of the 36 patients, only one required surgical treatment, while the others showed improvement without any complications. Compared to values before the procedure, calcific deposit size and VAS, ASES, and Constant scores showed significant improvement 6 weeks after the procedure. No significant correlation was found between the initial calcific deposit size and clinical outcomes at each time point. Conclusions: In patients with calcific tendinitis of the shoulder, US-guided barbotage using a spinal needle and subacromial steroid injection can yield satisfactory clinical and radiological results.

Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion (CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석)

  • Chang, You-Song;Cho, Kil-Ho;Byun, Woo-Mock;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.127-134
    • /
    • 1993
  • Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.

  • PDF

Experimental study on impact and spreading of SiO2 nanoparticle colloidal suspension droplets (SiO2 나노입자 현탁액의 충돌 및 퍼짐에 관한 실험적 연구)

  • Huh, H.K.;Lee, S.J.
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.3
    • /
    • pp.12-16
    • /
    • 2013
  • The impact and spreading behaviors of silicon dioxide nanoparticle colloidal suspension droplets were quantitatively visualized using a high-speed imaging system. Millimeter-scale droplets were generated by a syringe pump and a needle. Droplets of different velocity were impacted on a non-porous solid surface. Images were consecutively recorded using a CMOS high-speed camera at 5000 fps (frames per second) for millimeter-scale droplets. Temporal variations of droplet diameter, velocity and maximum spreading diameters were evaluated from the sequential images captured for each experimental condition. Effects of Reynolds number, Weber number, and particle concentration were investigated experimentally.

Useful of Magnetic Resonance Imaging in the Diagnosis and Surgical Plan of Intraperineal Lipoma in a Dog (자기공명영상이 개의 회음부 지방종의 진단 및 수술방법에 유용한 1예)

  • 송영성;장화석;김성미;김혜진;김순신;최치봉;김휘율
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.58-61
    • /
    • 2004
  • A 5-year old female shih-tzu referred to the veterinary Teaching Hospital, College of Veterinary Medicine, Konkuk University. The patient was presented with a mass of ventral to pubic region and intraperineal region. CBC, chemistry, x-ray, fine needle aspiration, biopsy and MRI was performed. The dog was definitively diagnosed as lipoma based on cytologic and histopathologic examination. In order to remove the mass, an approach with two direction was made. First, intraperineal region was removed about 40%, and then ventral to pubic was removed the remainder. And inserted penrose drain for obliterate dead space to prevent the accumulation of serous discharge. The dog is clinically normal and being monitored for development of any abnormal signs for the time being. In this case, diagnostic MRI was very useful procedure. it revealed accurate location of a lipoma and useful manner for decision of surgical approach to remove.

Effect of Induced Voltage on Spray Characteristics of Piezo Actuated Diesel Injector (인가전압이 디젤 피에조 인젝터의 분무 특성에 미치는 영향)

  • Lee, Jin-Woo;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.99-106
    • /
    • 2010
  • A piezo-driven injector was applied with a purpose to evaluate the effect of induced voltage on spray characteristics. For this, injection rate, macroscopic imaging, ambient gas entrainment and particle sizing were carried out. It was shown that initial slope of injection rate was steeper as induced voltage increased, while slope of injection rate became mostly constant with fully opened needle. From macroscopoic imaging, longer spray tip penetration was produced with higher induced voltage. Moreover, wider spray angle was detected in the early stage of spray development, when higher induced voltage was applied. Ambient air entrainment rate was increased and particle size was reduced with higher induced voltage.

Pancreatic metastasis from malignant phyllodes tumor of the breast

  • Lee, Seung Eun;Bae, Young Kyung;Choi, Joon Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.78-82
    • /
    • 2021
  • Pancreatic metastasis from malignant phyllodes tumor (PT) of the breast is rare, and only a few cases have been reported in the literature. Here, we report a case of pancreatic metastasis from malignant PT of the breast in a 48-year-old woman. She had had three episodes of recurrence of malignant PT in her right breast. She presented with epigastric pain for 2 months. Computed tomography and magnetic resonance imaging revealed a 6 cm-sized, well-defined, heterogeneous mass with peripheral enhancement in the body of the pancreas. Endoscopic ultrasonography-guided fine-needle aspiration was performed, and the pathologic report suggested spindle cell mesenchymal neoplasm. Subsequently, surgical excision was performed, and the mass was confirmed as a metastatic malignant PT. The imaging findings are discussed and the literature is briefly reviewed in this report.