• 제목/요약/키워드: Near-infrared region

검색결과 245건 처리시간 0.03초

THEORY AND PRINCIPLES OF NEAR INFRARED SPECTROSCOPY

  • Barton, Franklin E.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1012-1012
    • /
    • 2001
  • The elegant early experiments of Herschel demonstrated that there is light after the visible spectrum in a region we call the near infrared (NIR). This was followed by the work which showed that the spectrum went further into what we call the mid infrared (MIR). The MIR has been used for many years as a qualitative and quantitative region to measure constituent values. The MIR region contains the fundamental vibrations which can be theoretically calculated from symmetry rules and harmonic oscillator equations. The NIR is not as straight forward because the region from 400-2500 nm does not contain any of the fundamental vibrations only combination bands and overtones. Over the past fifty years efforts to understand the NIR have largely been ignored while the quantitative aspects of the region have been utilized. This presentation will focus on the efforts to define terms for NIR, examine the calculation of combination bands and overtones and ways to interpret the spectra. The interpretation of the NIR has been aided greatly in recent years by the use of two dimensional spectroscopy which allows the correlation of bands in one spectral region with that of the NIR.

  • PDF

Infrared Target Extraction Using Weighted Information Entropy and Adaptive Opening Filter

  • Bae, Tae Wuk;Kim, Hwi Gang;Kim, Young Choon;Ahn, Sang Ho
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.1023-1031
    • /
    • 2015
  • In infrared (IR) images, near targets have a transient distribution at the boundary region, as opposed to a steady one at the inner region. Based on this fact, this paper proposes a novel IR target extraction method that uses both a weighted information entropy (WIE) and an adaptive opening filter to extract near finely shaped targets in IR images. Firstly, the boundary region of a target is detected using a local variance WIE of an original image. Next, a coarse target region is estimated via a labeling process used on the boundary region of the target. From the estimated coarse target region, a fine target shape is extracted by means of an opening filter having an adaptive structure element. The size of the structure element is decided in accordance with the width information of the target boundary and mean WIE values of windows of varying size. Our experimental results show that the proposed method obtains a better extraction performance than existing algorithms.

DEEP INFRARED SURVEYS OF STAR FORMING REGIONS IN THE MWG AND LMC

  • NAKAJIMA YASUSHI
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.173-174
    • /
    • 2005
  • On behalf of the IRSF/SIRIUS group, I introduce some recent results from our deep near-infrared surveys (J, Hand Ks bands, limiting magnitude of Ks=17) toward star forming regions in the Milky Way Galaxy (MWG) and Large Magellanic Cloud (LMC) with the near-infrared camera SIRIUS. We discovered a rich population of low-mass young stellar objects associated with the W3 and NGC 7538 regions in the MWG based on the near-infrared colors arid magnitudes. The high sensitivity of our survey enables us to detect intermediate-mass pre-main sequence stars, i.e. HAEBE stars, even in the LMC. We detected many HAEBE candidate stars in the N159/N160 complex star forming region in the LMC with the IRSF 1.4-m telescope. Spatial distributions of the young stellar objects indicate the sequential cluster formation in each star forming region in the complex and large scale (a few ${\times}$ 100 pc) sequential cluster formation over the entire complex.

Near Infrared Diffuse Reflectance Spectroscopy to Measure Pulmonary Edema

  • Larry Leonardi;David H.Burns;Luis Openheimer;Rene P.Michel
    • Near Infrared Analysis
    • /
    • 제2권1호
    • /
    • pp.43-53
    • /
    • 2001
  • A non-invasive spectroscopic method is presented for the measurement of pulmonary edema. Both early diagnosis and quantitative edema estimates were investigated. The spectroscopic determination of pulmonary edema involved the acquisition of diffuse reflectance spectra in the near-infrared (NIR) region with change in water concentration - water is the main constituent of edema fluid. Pulmonary edema was induced into the excised perfused lungs of seven animals by elevating the hydrostatic pressure. Estimates of edema were ascertained from a partial least squares regression of the measured spectral response. Actual edema was determined from the change (increase) in total lung weight. Estimates in relative lung weight increases due to in vitro edema were made with the near infrared spectra. The results revealed that fluid accumulation produced spectral changes in the O-H and C-H absorptions as well as scattering changes in the spectra. Histology of the lung was used to verify the presence or absence of interstitial and alveolar edema. Results demonstrated that near infrared spectroscopy might provide a new tool for clinical assessment of pulmonary edema.

Novel optical properties of amorphous ferric hydroxide in near infrared region

  • Kang, Tae Yeon;Chae, Weon-Sik
    • Rapid Communication in Photoscience
    • /
    • 제4권2호
    • /
    • pp.34-36
    • /
    • 2015
  • New spectroscopic characteristics of amorphous ferric hydroxide ($Fe(OH)_3$), interestingly in the near infrared (NIR) region, are presented in this study. The absorption spectrum of ferric hydroxide covers wide spectral regions from ultraviolet to NIR (200~900 nm). Unique emission bands were newly observed in the NIR regions (800~1400 nm). Several bands of this NIR emission are quiet well overlapped with the combinational vibrational absorption bands of water. From photothermal conversion study, very interestingly, temperature of aqueous mixture solution including the amorphous ferric hydroxide was significantly increased from ambient temperature to $38^{\circ}C$ for 30 minutes under irradiation of a standard helium lamp.

DEVELOPMENT OF QUALITY EVALUATION SYSTEM FOR PEANUT WITH POD USING OPTICAL METHODS

  • Morta, Kazuo;Taharazako, Shoji;Zhang, Han;Maekaji, Kenji;Ikeda, Hirohiko
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1354-1363
    • /
    • 1993
  • Optical methods were developed to examine their feasibility for quality evaluation of peanut with pod. Surface color and internal quality of peanut were measured without contact. The surface color of peanut was measured by light reflectance at a region of visible wavelengths. Its characteristic was high correlated with a visual grading of peanut. A trial machine for the color grading of peanut was developed using an optical sensor and it was considered to compare with the visual grading. The spectral reflectance at a region of near infrared wavelengths from 1,200 to 2,500nm was measured , and the chemical components of peanut were related to spectral reflectance at special wavelengths. The protein, fat and moisture contents of peanut were estimated by the near infrared methods. An infrared imaging method was developed to evaluate the internal quality of peanut with pod. As thermal characteristic of peanut with pod was deeply related to internal quality , the quality of peanut can be evaluated by temperature changes on the surface of peanut. Measurement of surface color, near infrared reflectance and thermal imaging were shown to be very effective in grading of peanut with pod.

  • PDF

이리듐이 첨가된 니켈실리사이드의 적외선 흡수 특성 (IR Absorption Property in Nano-thick Ir-inserted Nickel Silicides)

  • 윤기정;송오성;한정조
    • 대한금속재료학회지
    • /
    • 제46권11호
    • /
    • pp.755-761
    • /
    • 2008
  • We fabricated thermally evaporated 10 nm-Ni/1 nm-Ir/(poly)Si films to investigate the energy saving property of silicides formed by rapid thermal annealing (RTA) at the temperature range of $300{\sim}1200^{\circ}C$ for 40 seconds. Moreover, we fabricated 100 nm-thick ITO/(poly)Si films with an rf-sputter as references. A transmission electron microscope (TEM) and an X-ray diffractometer were used to determine cross-sectional microstructure and phase changes. A UV-VIS-NIR and FT-IR (Fourier transform infrared spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM analysis, we confirmed 20~65 nm-thick silicide layers formed on the single and polycrystalline silicon substrates. Ir-inserted nickel silicide on single crystalline substrate showed almost the same absorbance in near IR region as well as ITO, but Ir-inserted nickel silicide on polycrystalline substrate, which had the uniform absorbance in specific region, showed better absorbance in near IR region than ITO. The Ir-inserted nickel silicide on polycrystalline substrate particularly showed better absorbance in middle IR region than ITO. The results imply that nano-thick Ir-inserted nickel silicides may have excellent absorbing capacity in near-IR and middle-IR region.

SH 2-128, AN H II AND STAR FORMING REGION IN AN UNLIKELY PLACE

  • BOHIGAS JOAQUIN;TAPIA MAURICIO
    • 천문학회지
    • /
    • 제37권4호
    • /
    • pp.285-288
    • /
    • 2004
  • Near-infrared imaging photometry supplemented by optical spectroscopy and narrow-band imaging of the H II region Sh 2-128 and its environment are presented. This region contains a developed H II region and the neighboring compact H II region S 128N associated with a pair of water maser sources. Midway between these, the core of a CO cloud is located. The principal ionizing source of Sh 2-128 is an 07 star close to its center. A new spectroscopic distance of 9.4 kpc is derived, very similar to the kinematic distance to the nebula. This implies a galactocentric distance of 13.5 kpc and z = 550 pc. The region is optically thin with abundances close to those predicted by galactocentric gradients. The $JHK_s$ images show that S 128N contains several infrared point sources and nebular emission knots with large near-infrared excesses. One of the three red Ks knots coincides with the compact H II region. A few of the infrared-excess objects are close to known mid- and far-infrared emission peaks. Star counts in J and $K_s$ show the presence of a small cluster of B-type stars, mainly associated with S 128N. The $JHK_s$ photometric properties together with the characteristics of the other objects in the vicinity suggest that Sh 2-128 and S 128N constitute a single complex formed from the same molecular cloud, with ages ${\~}10^6$ and < $3 {\times} 10^5$ years respectively. No molecular hydrogen emission was detected at 2.12 ${\mu}m$. The origin of this remote star forming region is an open problem.

Investigation of a series of near-infrared absorbing heptamethine cyanine dyes

  • 윤혜수;박수열;신승림;신종일;안경룡;이상오;오성근;전근
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2009년도 제41차 학술발표회
    • /
    • pp.115-116
    • /
    • 2009
  • In this study, near-infrared absorbing dyes, namely, new rigidified heptamethine cyanine dyes were synthesized and investigated their properties. The cyanine dyes have been synthesized by a condensation reaction between a quanternary salt containing as activated methyl group and an unsaturated bisaldehyde or its equivalent. We were investigated the synthesis of new rigidified heptamethine cyanine and related the compounds with near infrared absorption. The full spectroscopic characterization of all cyanine were described. Absorption properties in the near-infrared region may cause these dyes to the potential used in bio-probe, optical recording media materials.

  • PDF

적응적 구조요소를 이용한 열림 연산자에 의한 적외선 영상표적 추출 (Shape Extraction of Near Target Using Opening Operator with Adaptive Structure Element in Infrared hnages)

  • 권혁주;배태욱;김병익;이성학;김영춘;안상호;송규익
    • 한국통신학회논문지
    • /
    • 제36권9C호
    • /
    • pp.546-554
    • /
    • 2011
  • 적외선 영상의 근거리 표적 (near targets)은 표적의 내부영역은 화소 값이 균일하고, 경계 영역은 배경과 인접해 있기 때문에 화소 값 변화가 불균일하다. 이러한 특성에 기초하여 본 논문은 적응적 구조요소 (adaptive structure element)를 이용한 열림 연산자에 의한 적외선 영상 표적 검출 기법을 제안한다 먼저, 국부 분산 가중치 정보 엔트로피 (weighted information entropy, WIE)를 이용하여 후보 표적군의 위치와 경계영역을 추출한 후, 이 경계 영역에 대하여 라벨링 연산을 수행하여 대략의 표적 영역을 검출한다. 이 대략의 표적 영역에 대하여 제한한 적응적 구조 요소를 이용한 열림 연산자를 수행함으로써 정확한 표적 모양을 검출한다. 이 구조 요소는 표적 경계 영역에서 필터창의 가중치 정보 엔트로피의 평균값을 계산함으로써 얻어진 표적 경계 폭에 의한 결정된다. 실험 결과로부터 제안한 방법이 기존의 방법에 비해 추출 성능이 뛰어남을 확인할 수 있었다.