• 제목/요약/키워드: Near-field noise

검색결과 276건 처리시간 0.021초

에어포일 이산소음 특성에 관한 연구 (A Study on Discrete Frequency Noise from a Symmetrical Airfoil in a Uniform Flow)

  • 김휘중;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.646-651
    • /
    • 2002
  • The flow field around a symmetrical airfoil in a uniform flow under the generation of noise was studied by experiments and numerical simulation. The experiments are conducted by visualizing the surface flow over the airfoil with a shear-sensitive liquid-crystal coating and by measuring the instantaneous velocity field around the trailing edge of the airfoil. The results indicate that the discrete frequency noise is generated when the separated laminar flow reattaches near the trailing edge of the pressure side and the turbulent boundary layer is formed over the suction side of the airfoil near the trailing edge. The periodic behavior of vortex formation was observed around the trailing edge and it persists further downstream in the wake. The frequency of the vortex formation in the wake was consistent with that of the discrete frequency noise.

  • PDF

복소음향인텐시티법을 이용한 HVAC의 소음원 검출 (Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method)

  • 양정직;이동주
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구 (Experiments for the Acoustic Source Localization in 2D Cavity Flow)

  • 이재형;박규철;최종수
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명 (Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array)

  • 이재형;최종수;박규철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF

수중반사파 환경에서의 근접음장 홀로그래피 적용에 대한 오차 고찰 (Error Investigation in use of Near-field Acoustic Holography in the Underwater Environment of Reflected Wave)

  • 이종주;강명환;한승진;정현주;배수룡;정우진
    • 한국소음진동공학회논문집
    • /
    • 제24권12호
    • /
    • pp.969-976
    • /
    • 2014
  • Nowadays, it is required for naval ships to estimate 3D underwater radiated noise pattern in all direction at peak frequencies of hull vibration for the reduction of being detected and doing the effective operation. For this purpose, the numerical method has to be developed to calculate 3D underwater radiated noise pattern with experimental data. It is very difficult to obtain the experimental data for the real ship. Alternative to get the experimental results is to use NAH(near-field acoustic holography) in acoustic tank with experimental model. Application of NAH in acoustic tank for the experimental model needs some investigation of reflection wave from the wall of the acoustic tank and unmeasured zone of the experimental model due to the supporting structure for it. In this study, the effect of reflection wave in the acoustic tank and unmeasured area of the experimental model when using the NAH was investigated with experiment and numerical model. From these, it is known for the error due to reflection wave can be reduced when the distance between the measurement plane and source is being shorten. Also, unmeasured area of the experimental model gives rise to some error in the estimation of the far-field acoustic pressure.

수중실험을 통한 원통구조물의 3차원 수중방사소음 패턴 산출기법 분석 (A Analysis on the Estimation Method of the 3D Underwater Radiation Noise Pattern of Cylindrical Structure with the Underwater Experiments)

  • 이종주;강명환;한승진;정현주;오준석;배수룡;정우진;서영수
    • 한국소음진동공학회논문집
    • /
    • 제24권11호
    • /
    • pp.907-918
    • /
    • 2014
  • In this study for the prediction of 3D underwater radiated noise pattern, a comparison between the proposed method(DHIE, Discrete Helmholtz Integral Equation) and the 3D underwater radiated noise calculation results using the measurement of near-field acoustic pressure data is performed. The near-field acoustic pressure in water is measured for the calculation of the far-field radiated noise pattern and the far-field acoustic power. Also the vibration field of the underwater structure is measured in simultaneously. Using the total far-field acoustic power and the vibration field on the surface of the structure, the proposed method(DHIE) can predict the underwater radiated noise pattern of the far-field The predicted results show the reasonable agreement within about 5dB comparing with the experiment result.

에어컨 실외기에서의 유동소음 (Flow Noise in the Outdoor Unit of an Air-conditioner)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

냉각탑의 방사소음특성에 관한 연구 (A Study on the Noise Characteristics of Cooling Tower)

  • 박보용;김인수;이상환
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.361-374
    • /
    • 1996
  • In general, a cooling tower has two major noise sources, one is the fan and the other is the falling water. The fan noise is produced by passage of its blades through the air and radiates from the fan stack. Noises from the falling water are caused by splashing and dropping of water cascading over the internal filler of the cooling tower and into the basin and radiate from the louvered face. In this paper, the noise measurements and its frequency analysis are carried out for the locations facing the louvered side and near the fan stack referring the related code and standards in order to study the noise characteristics of the induced-draft cooling tower, especially for the buildings. As a result, it is found that for every doubling of distance from the noise source the noise level decreases by 2~4dBA in the near field with reflect surfaces and decreases by about 6dBA also in the far field without reflect surfaces. As a supplement to the noise measurements, a computer program with simple algorithm is developed in order to estimate the noise level at a distance from the cooling tower, so that the user could apply and modify it for the particular boundary conditions easily.

  • PDF

A-SIL 을 이용한 근접장 저장 (Advanced SIL(A-SIL) system for Near Field Recording)

  • 한인구;신윤섭;박진무;이정욱;서정교;최인호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1028-1030
    • /
    • 2007
  • Mutual compensating concept between SIL(Solid Immersion Lens) and OL(Objective Lens) of NFR(Near Field Recording) is proposed, designed and manufactured to achieve a high NA and obtain a wider manufacturing tolerance. Tolerance information is present in article. An effective NA of Advanced SIL is 1.7 and adjustment between OL and SIL is carried out using our interferometer. We measured very clear RF signal using 3-axis actuator at Test bed.

  • PDF

IMP를 이용한 근접장 기록 장치의 디스크 진동 및 편심 보상 (Disk Vibration and Eccentricity Compensation of Near Field Recoding Systems Based on the Internal Model Principle)

  • 정준;김중곤;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.837-842
    • /
    • 2007
  • Information storage devices using disks have a disk vibration at the frequency which is equivalent to the disk rotational speed. They also have a track vibration due to the disk eccentricity at the same frequency. In near field recording systems, the former affects the air-gap servo and the latter affects the tracking servo. In this paper, we introduce a novel control algorithm based on the internal model principle to both servos. A controller block designed by the principle is connected to the base lead-lag type compensator in parallel in order to cancel the repeatable run-out due to the disk vibration or eccentricity. Simulation and practical application of the algorithm on a near field recording system show good servo performance.

  • PDF