• 제목/요약/키워드: Near-Infrared

검색결과 1,692건 처리시간 0.026초

Studies on pharmaceutical assay method using Near Infrared Spectroscopy (NIRS) (II)

  • Kang, Shin-Jung;Yun, Mi-Ok;Lee, Su-Jung;Choi, Hyun-Chul;Kim, Ho-Jeong;Kim, Ji-Yeon
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4113-4113
    • /
    • 2001
  • This study developed effective assay method of pharmaceutical quality control was developed by near-infrared spectroscopy (NIRS). The calibration equation model of assay was developed by 2nd deriviative PLS(Partial Least Squares) regression method with NIRS over the wavelength range from 1100 to 1400nm using diazepam tablets (2mg, 5mg). Although diazepam tablets are made by 5-different manufacture, they have similar formulation. When the correlation was compared with values by NIRS and HPLC, the R-2s and standard error of calibration (SEC) for 2mg were 0.9300 and 0.98%, the R-2s and SEC for 5mg were 0.9165 and 0.63%. The validation of the calibration equation model yield that the R-2s and standard error of prediction (SEP) for 2mg were 0.9611 and 0.995%, the R-2s and SEP for 5mg were 0.9114 and 0.842%. The method was validated on assay method for diazepam tablets by the calibration equation.

  • PDF

Self-Modeling Curve Resolution Analysis of On-line Near Infrared Spectra Measured during the Melt-Extrusion Transesterification of Ethylene/Vinylacetate Copolymer

  • Sasic, Slobodan;Kita, Yasuo;Furukawa, Tsuyoshi;Watari, Masahiro;Siesler, Heinz W.;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1284-1284
    • /
    • 2001
  • The transesterification of molten ethylene/vinylacetate (EVA) copolymers by octanol as a reagent and sodium methoxide as a catalyst in an extruder has been monitored by on-line near infrared (NIR) spectroscopy. A total of 60 NIR spectra were acquired for 37 minutes with the last spectrum recorded 31 minutes after the addition of octanol and catalyst was stopped. The experimental spectra show strong baseline fluctuations which are corrected for by multiplicative scatter correction (MSC). The chemometric methods of orthogonal projection approach (OPA) and multivariate curve resolution (MCR) were used to resolve the spectra and to derive concentration profiles of the species. The detailed analysis reveals the absence of completely pure variables that leads to small errors in the calculation of pure spectra. The initial estimation of a concentration that is necessary as an input parameter for MCR also presents a non-trivial task. We obtained results that were not ideal but applicable for practical concentration control. They enable a fast monitoring of the process in real-time and resolve the spectra of the EVA copolymer and the ethylene/vinyl alcohol (EVAL) copolymer to be very close to the reference spectra. The chemometric methods used and the decomposed spectra are discussed in detail.

  • PDF

Two-dimensional near-infrared correlation spectroscopy, principal component analysis and water structure

  • Sectnan, Vegard H.;Sasic, Slobodan;Isaksson, Tomas;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1287-1287
    • /
    • 2001
  • The structure of water molecules in the pure liquid state has been subjected to extensive research for several decades. Questions still remain unanswered, however, and no single model has been found capable of explaining all the anomalies of water. In the present study near-infrared spectra of water in the temperature region 6-$80^{\circ}C$ have been analysed by use of principal component analysis (PCA) and two-dimensional correlation spectroscopy in order to study the dynamic behaviour of the water band centred at 1440 nm, which is due to the combination of symmetric and antisymmetric O-H stretching modes. It has been found that the wavelengths 1412 and 1491 nm account for more than 99% of the spectral variation, representing two major water species with weaker and stronger hydrogen bonds, respectively. A third species located at 1438 nm, whose concentration was relatively constant as a function of temperature, is also indicated. A somewhat distorted two-state structural model for water is suggested.

  • PDF

MONITORING THE EFFECT OF THE ULTRA-HIGH PRESSURE PRESERVATION TECHNOLOGY BY NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Kaffka, Karoly J.;Farkas, Jozsef;Seregely, Zsolt;Meszaros, Laszlo
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.2122-2122
    • /
    • 2001
  • The ultra-high pressure technology fur the preservation of foods is under intense research to evaluate its potential as an alternative or complementary process to traditional methods of food preservation. Traditional processing methods usually need a large amount of energy, may cause unwanted reactions in the food, leading to cooked flavor and loss of vitamins, etc. The application of ultra-high hydrostatic pressure for food processing consists of subjecting the food to pressures in the range of 100-1000 ㎫. The ultra-high pressure inactivates the microorganisms and some enzymes, promotes the germination of spores and extends the shelf-life of the foods. This new technology follows the “minimal processing” concept minimizing the quality degradation, saving the vitamins, essential nutrients and flavors as well as utilizing less energy. We joined the research team at our University involved in the mentioned technology using an ultra-high pressure equipment, recording of the near infrared spectra and signal response of a chemosensor array (electronic nose) of their meat (beef and pork), vegetable and fruit samples exposed to different pressure. The results of our investigations achieved by evaluating the measured data using PCA and PQS methods will be presented.

  • PDF

DEVELOPMENT OF PORTABLE NEAR INFRARED SYSTEM FOR HUMAN SKIN MOISTURE

  • Woo, Young-Ah;Ahn, Jhii-Weon;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3115-3115
    • /
    • 2001
  • In this study, portable near infrared (NIR) system was newly integrated with a photodiode array detector, which has no moving parts and this system has been successfully applied for evaluation of human skin moisture. The good correlation between NIR absorbance and absolute water content of separated hairless mouse skin was, in vitro, showed depending on the water content (7.42-84.94%) using this portable NIR system. Partial least squares (PLS) regression was used for the calibration with the 1100-1650 nm wavelength range. For the practical use for the evaluation of human skin based on moisture, PLS model for human skin moisture was, in vivo, developed using the portable NIR system based on the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. This study indicated that the portable NIR system could be a powerful tool for human skin moisture, which may be much more stable to environmental conditions such as temperature and humidity, compared to conventional methods. Furthermore, in order to confirm the performance of newly integrated portable NIR system, scanning type conventional NIR spectrometer was used in the same experiments and the results were compared.

  • PDF

Water-Methanol and Water-Acetonitrile Mixture Analysis using NIR Spectral Data and Iterative Target Transform Factor Analysis

  • Na, Dae-Bok;Hur, Yun-Jeong;Park, Young-Joo;Cho, Jung-Hwan
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1289-1289
    • /
    • 2001
  • Water-methanol and water-acetonitrile mixtures are frequently used as HPLC solvent system and strong hydrogen bonding is well-known. But a detailed aspect of water-methanol and/or water-acetonitrile mixtures have not been shown with direct spectral evidence. Recently, near infrared spectroscopy and chemometric data refinery have been successfully combined in many applications. On the basis of factor analytical methods, the spectral features of water-methanol and water-acetonitrile mixtures were studied to reveal the detail of mixtures. Water-methanol and water-acetonitrile mixtures were prepared with varying concentration of each constituent and near infrared spectral data were acquired in the range of 1100-2500nm with 2-nm interval. The data matrices were analysed with ITTFA(Iterative Target Transform Factor Analysis) algorithm implemented as MATLAB codes. As a result, the concentration profiles of water, methanol and water-methanol complex were resolved and the spectra of water-methanol complexes were calculated, which cannot be acquired with pure complexes. A similar result was obtained with NIR spectral data of water-acetonitrile mixtures. Moreover, pure spectra of hydrogen-bonding complexes of water-methanol and water-acetonitrile can be computed, while any other usual physical methods cannot isolated those complexes for acquiring pure component spectra.

  • PDF

Effect of particle size and scanning cup type for near infrared reflection on the soil property measurement

  • Ryu, Kwan-Shig;Cho, Rae-Kwang;Park, Woo-Churl;Kim, Bok-Jin
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.35-39
    • /
    • 2000
  • The purpose of this research was to find out suitable soil sample preparation and sample holding tools for NIR reflection radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1,100 to 2,500nm with an InfraAlyzer 500(Bran+Luebbe Co.). Coarse(2.0mm) and fine(0.5mm) soil sample and various sample holding tools were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter and total nitrogen of the soils. Multiple linear regression was used to obtain the best correlation of NIR spectroscopy method. Correlation of NIR spectroscopy method. Correlation of NIR spectra for finely and coarsely sized soil did not show much difference. The standard errors of prediction(SE) using different types of sample holding tools for organic matter, total nitrogen and soil moisture were better than 0.765, 0.041 and 0.63% respectively. From the results it can be concluded that NIR spectroscopy with flow type cell could be used as a fast routine testing method in quantitative determination of organic matter, total nitrogen and soil moisture.

Discrimination of geographical origin and cultivation years of Ginseng by near Infrared reflectance spectroscopy

  • Lin, Guo-Lin;Sohn, Mi-Ryeong;Cho, Rae-Kwnag;Hong, Jin-Hwan
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.41-44
    • /
    • 2000
  • The objectives of this study are to discriminate the geographical origin and cultivation years of ginseng based on the near-infrared(NIR) reflectance spectroscopic analysis. Korea and China ginseng samples were prepared for discrimination of geographical origin. 4, 5 and 6 years-old ginseng samples from Korea were prepared for discrimination of cultivation years. Used spectrometer were InfraAlyzer 500, InfraAlyzer 400 and Fiber optic. Sample type of ginseng was 3, whole ginseng radix, slide section and powder type. The accuracy was affected by sample types and instruments. The accuracy for discrimination geographical origin was 97% in calibration model using IA 500 and ginseng powder. For discrimination of cultivation years, the model with slide selection using IA500 were relative accurate. The accuracy was 96.7% for 4-year, 91.3% for 5-year and 89.3% for 6-year old ginseng. The study shows that NIR spectroscopic analysis can be used to discriminate the geographical origin and cultivation years of ginseng with acceptable accuracy.

일본의 근적외선분광법에 대한 제약회사 응용 및 현황 (Application Study of Chemoinfometrical Near-Infrared Spectroscopic Method to Evaluate for Polymorphic Content of Pharmaceutical Powders)

  • Otsuka, Makoto
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2002년도 강연요지집
    • /
    • pp.97-117
    • /
    • 2002
  • A chemoinfometrical method for quantitative determination of crystal content of indomethacin (IMC) polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the conventional powder X-ray diffraction method was performed. Pure $\alpha$ and ${\gamma}$ forms of IMC were prepared using published methods. Powder X-ray diffraction profiles and NIR spectra were recorded for six kinds of standard materials with various content of ${\gamma}$ form IMC. The principal component regression (PCR) analyses were performed based on normalized NIR spectra sets of standard samples of known content of IMC ${\gamma}$ form. A calibration equation was determined to minimize the root mean square error of the prediction. The predicted ${\gamma}$ form content values were reproducible and had a relatively small standard deviation. The values of ${\gamma}$ form content predicted by two methods were in close agreement. The results were indicated that NIR spectroscopy provides for an accurate quantitative analysis of crystallinity in polymorphs compared with the results obtained by conventional powder X-ray diffractometry.

  • PDF

Application of Functional Near-Infrared Spectroscopy to the Study of Brain Function in Humans and Animal Models

  • Kim, Hak Yeong;Seo, Kain;Jeon, Hong Jin;Lee, Unjoo;Lee, Hyosang
    • Molecules and Cells
    • /
    • 제40권8호
    • /
    • pp.523-532
    • /
    • 2017
  • Functional near-infrared spectroscopy (fNIRS) is a noninvasive optical imaging technique that indirectly assesses neuronal activity by measuring changes in oxygenated and deoxygenated hemoglobin in tissues using near-infrared light. fNIRS has been used not only to investigate cortical activity in healthy human subjects and animals but also to reveal abnormalities in brain function in patients suffering from neurological and psychiatric disorders and in animals that exhibit disease conditions. Because of its safety, quietness, resistance to motion artifacts, and portability, fNIRS has become a tool to complement conventional imaging techniques in measuring hemodynamic responses while a subject performs diverse cognitive and behavioral tasks in test settings that are more ecologically relevant and involve social interaction. In this review, we introduce the basic principles of fNIRS and discuss the application of this technique in human and animal studies.