• Title/Summary/Keyword: Near infrared

Search Result 1,693, Processing Time 0.023 seconds

THE EVOLUTION OF AGB STARS ON INFRARED 2-COLOR DIAGRAMS

  • Suh, Kyung-Won;Lee, Jae-Woo;Kim, Hak-Youn
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.15-20
    • /
    • 2001
  • We present infrared 2-color diagrams of AGB stars from the observations at near infrared and IRAS point source catalog (PSC) data. We compile the observations for thousands of newly identified OH/IR stars and carbon stars. We compare the observations with the theoretical evolutionary tracks of AGB stars. From the new observational data base and theoretical tracks, we discuss the meaning of the infrared 2-color diagrams.

  • PDF

INFRARED COLOR-COLOR DIAGRAMS FOR AGB STARS

  • Suh, kyung-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.3
    • /
    • pp.197-202
    • /
    • 2007
  • We present infrared color-color diagrams of AGB stars from the observations at near and mid infrared bands. We compile the observations for hundreds of OH/IR stars and carbon stars using the data from the Midcourse Space Experiment (MSX), the two micron sky survey (2MASS), and the IRAS point source catalog (PSC). We compare the observations with the theoretical evolutionary tracks of AGB stars. From the new observational data base and the theoretical evolution tracks, we discuss the meaning of the infrared color-color diagrams at different wavelengths.

Desktop-LED lighting for Eye Muscle Movement by Adjusting the Light Illuminance and Color Temperature

  • Kim, Byoung-Chul;Kim, Seon-Jong;Kim, Joo-Man
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.203-208
    • /
    • 2020
  • In this paper, we propose the design and implementation of a desktop LED stand and smart app that automatically adjusts color temperature and illuminance for optimal brightness and eye health by improving the structural problem of the LED stand. It is a tabletop LED stand that supports optimal brightness through color temperature control and heat transfer through infrared LED to relieve eye strain through blood circulation and muscle movement. The LED stand works with the smartphone to automatically adjust the optimal brightness and color temperature for the user's environment. In addition, the brightness of the infrared LED is adjusted to a living frequency of 4Hz to relax the eye muscles and reduce eye strain. This study implemented an effective measured data-based system of previous studies through the color temperature and illumination of LED lighting, and near-infrared rays, and presented meaningful results by conducting an experiment to prove the effect through subjects.

Near-IR TRGB Distance to Nearby Dwarf Irregular Galaxy NGC 6822

  • Sohn, Y.J.;Kang, A.;Han, W.;Park, J.H.;Kim, H.I.;Kim, J.W.;Shin, I.G.;Chun, S.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.3
    • /
    • pp.249-254
    • /
    • 2008
  • We report the distance modulus of nearby dwarf irregular galaxy NGC 6822 estimated from the so-called Tip of Red-giant Branch (TRGB) method. To detect the apparent magnitudes of the TRGB we use the color-magnitude diagrams (CMDs) and luminosity functions (LFs) in the near-infrared JHK bands. Foreground stars, main-sequence stars, and supergiant stars have been classified on the (g - K, g) plane and removed on the near-infrared CMDs, from which only RGB and AGB stars are remained on the CMDs and LFs. By applying the Savitzky-Golay filter to the obtained LFs and detecting the peak in the second derivative of the observed LFs, we determined the apparent magnitudes of the TRGB. Theoretical absolute magnitudes of the TRGB are estimated from Yonsei-Yale isochrones with the age of 12Gyr and the metallicity range of -2.0 <[Fe/H]< -0.5. The derived values of distance modulus to NGC 6822 are (m - M) = $23.35{\pm}0.26$, $23.20{\pm}0.42$, and $23.27{\pm}0.50$ for J, H, and K bands, respectively. Distance modulus in bolometric magnitude is also derived as (m - M) = $23.41{\pm}0.17$. We compare the derived values of the TRGB distance modulus to NGC 6822 in the near-infrared bands with the previous results in other bands.

Near Infrared Spectroscopy for Diagnosis: Influence of Mammary Gland Inflammation on Cow´s Milk Composition Measurement

  • Roumiana Tsenkova;Stefka Atanassova;Kiyohiko Toyoda
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 2001
  • Nowadays, medical diagnostics is efficiently supported by clinical chemistry and near infrared spectroscopy is becoming a new dimension, which has shown high potential to provide valuable information for diagnosis. The investigation was carried out to study the influence of mammary gland inflammation, called mastitis, on cow´s milk spectra and milk composition measured by near infrared spectroscopy (NIRS). Milk somatic cell counts (SCC) in milk were used as a measure of mammary gland inflammation. Naturally occurred variations with milk composition within lactation and in the process of milking were included in the experimental design of this study. Time series of unhomogenized, raw milk spectral data were collected from 3 cow along morning and evening milking, for 5 consecutive months, within their second lactation. In the time of the trial, the investigated cows had periods with mammary gland inflammation. Transmittance spectra of 258 milk samples were obtained by NIRSystem 6500 spectrophotometer in 1100-2400 nm region. Calibration equations for the examined milk components were developed by PLS regression using 3 different sets of samples: samples with low somatic cell count (SCC), samples with high SCC and combined data set. The NIR calibration and prediction of individual cow´s milk fat, protein, and lactose were highly influenced by the presence of mil samples from animals with mammary gland inflammation in the data set. The best accuracy of prediction (i.e. the lower SEP and the higher correlation coefficient) for fat, protein and lactose was obtained for equations, developed when using only “healthy” samples, with low SCC. The standard error of prediction increased and correlation coefficient decreased significantly when equations for low SCC milk were used to predict examined components in “mastitis” samples with high SCC, and vice versa. Combined data set that included samples from healthy and mastitis animals could be used to build up regression models for screening. Further use of separate model for healthy samples improved milk composition measurement. Regression vectors for NIR mild protein measurement obtained for “healthy” and “mastitic” group were compared and revealed differences in 1390-1450 nm, 1500-1740 nm and 1900-2200 nm regions and thus illustrated post-secretory breakdown of milk proteins by hydrolytic enzymes that occurred with mastitis. For the first time it has been found that monitoring the spectral differences in water bands at 1440 nm and 1912 nm could provide valuable information for inflammation diagnosis.

Conceptual Design Study of NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Park, Kwijong;Lee, Dae-Hee;Moon, Bongkon;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Park, Chan;Ko, Kyeongyeon;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.82.2-82.2
    • /
    • 2013
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is being developed by KASI. The NISS will perform the imaging low-resolution spectroscopic observation in the near-infrared range for nearby galaxies, low background regions, starforming regions and so on. The off-axis reflecting telescope with a wide field of view (2 deg. ${\times}$ 2 deg.) will be operated in the wavelength range from 0.95 to $3.8{\mu}m$. In order to reduce thermal noise, a telescope and a HgCdTe infrared sensor will be cooled down to 200K and 80K, respectively. To evade a stray light outside a field of view and use limited space efficiently, the NISS adopted the off-axis reflective optical system. The primary and secondary mirrors, optomechanical part and mechanical structure were designed to use the same material. It will lessen the degradation of optical performance due to a thermal variation. The purpose of NISS is the observation of cosmic near-infrared background in the wide wavelength range as well as the detection of near-infrared spectral lines in nearby galaxies, cluster of galaxies and star forming regions. It will give us less biased information on the star formation history. In addition, we will demonstrate the space technologies related to the development of the Korea's leading near-infrared instrument for the future large infrared telescope, SPICA.

  • PDF

The Near-IR TRGB Magnitude and Distance Modulus to NGC 185

  • Sohn, Y.J.;Kang, A.;Han, W.;Park, J.H.;Kim, H.I.;Kim, J.W.;Shin, I.G.;Chun, S.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.3
    • /
    • pp.245-248
    • /
    • 2008
  • We determined values of distance modulus to nearby dwarf galaxy NGC 185 from the Tip of Red-Giant Branch (TRGB) method. Apparent magnitudes of the TRGB are estimated from the near-infrared JHK luminosity functions (LFs) of the resolved giant branch stars. Theoretical absolute magnitudes of the TRGB in near-infrared bands have been extracted from the Yonsei-Yale isochrones. The observed apparent and theoretical absolute magnitudes of the TRGB provide values of distance modulus to NGC 185 as (m - M) = $23.39{\pm}0.14$, $23.23{\pm}0.22$, and $23.27{\pm}0.26$ for J,H, and K bands, respectively. Distance modulus in bolometric magnitude is also derived as (m - M) = $23.62{\pm}0.12$.

Near-IR TRGB Distance Modulus of Dwarf Irregular Galaxy IC 1613

  • Jung, M.Y.;Chun, S.H.;Chang, C.R.;Han, M.;Lim, D.;Han, W.;Sohn, Y.J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.421-424
    • /
    • 2009
  • The $JHK_S$ magnitudes of the red giant branch tip (TRGB) and the distance moduli of the nearby dwarf irregular galaxy IC 1613 have been determined from the near-infrared luminosity functions (LFs) of the resolved stars in the galaxy. Applying a Savitzky-Golay filtering, we derived the second derivatives of the LFs, and estimated the apparent magnitudes of the TRGB as $m_J\;=\;19.1$, $m_H\;=\;18.4$, and $m_{Ks}\;=\;18.0$. The mean values of the theoretical absolute magnitudes of the TRGB were measured by using the Yonsei-Yale isochrones with a metallicity range of -2.1 < [Fe/H] < -0.5 and age of 12 Gyr. The derived values of near-infrared TRGB distance moduli for IC 1613 are (m - M) = $24.12{\pm}0.25$, $24.20{\pm}0.44$, and $24.00{\pm}0.52$ for J, H, and $K_S$ bands, respectively.

NEAR-IR TRGB DISTANCE TO DWARF ELLIPTICAL GALAXY NGC 147

  • Kang, A.;Kim, J.W.;Shin, I.G.;Chun, S.H.;Kim, H.I.;Sohn, Y.J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.3
    • /
    • pp.203-208
    • /
    • 2007
  • We report the distance modulus of nearby dwarf elliptical galaxy NGC 147 estimated from the Tip of Red-giant Branch (TRGB) method applying to the color-magnitude diagrams and luminosity functions in the near-infrared JHK bands. Apparent magnitudes of TRGBs in each band are obtained by applying Savitzky-Golay filter to the luminosity functions, and the theoretical absolute magnitudes are estimated from Yonsei-Yale isochrones. The derived values of distance modulus to NGC 147 are $(m-M)=23.69{\pm}0.12,\;23.78{\pm}0.17,\;and\;23.85{\pm}0.22\;for\;J,\;H,\;and\;K$ bands, respectively. Distance modulus in bolometric magnitude is also derived as $(m-M)=23.87{\pm}0.11$. We compare the derived values of the TRGB distance modulus to NGC 147 in the near-infrared bands with the previous results in other bands.