• Title/Summary/Keyword: Near infrared

Search Result 1,693, Processing Time 0.058 seconds

Application of Near Infrared Reflectance Spectroscopy as a Rapid Leaf Analysis Method to Evaluate Nutritional Diagnosis in Apple (Malus Domestica Borkh, Fuji) and grape(Vitis Labrusca, Campbell Early) (영양진단을 위한 신속한 엽분석 방법으로서 근적외분광분석기의 이용)

  • Seo, Young-Jin;Park, Man;Kim, Chang-Bae;Kim, Jong-Su;Yoon, Jae-Tak;Cho, Rae-Kwang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.4
    • /
    • pp.242-246
    • /
    • 2000
  • The Near Infrared Reflectance Spectroscopy(NIR) was used to evaluate nutritional diagnosis for rapid leaf analysis method, 177 'Fuji' apple and 130 'Campbell Early' grape leaves were measured by Near Infrared reflectance spectra in the NIR region(1,100~2.500nm). Total nitrogen content was measured by kjelldhal distillation, after salycilic acid-sulfuric acid digestion. An empirical equation to predict total nitrogen content from its spectral signature was developed by adapting the Near Infrared Reflectance Spectroscopy analysis(NIRa) technique and the results were apple-0.965(R). 0.086(SEC), grape-0.926(R), 0.152(SEC). Standard Error of Prediction(SEP) of NIRa for predicting the total nitrogen of apple and grape leaves was 0.360 and 0.210, respectively. It was concluded that Near infrared reflectance spectroscopy analysis is promising method for rapid analysis of apple and grape leaves.

  • PDF

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

Determination of Chemical Composition of Toasted Burley Tobacco by Near Infrared Spectroscopy (근적외선분광법을 이용한 버어리 토스트엽의 화학성분 분석)

  • 김용옥;정한주;백순옥;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.2
    • /
    • pp.177-183
    • /
    • 1995
  • This study was conducted to develop the most precise NIR(near infrared spectrometric) calibration for rapid determination of chemical composition in ground samples of toasted burley tobacco using stepwise, stepup, principal component regression(PCR), partial least square(PLS) and modified partial least square(MPLS) calibration method. The number of wavelength(W) selected by stepup multiple linear regression using: second derivative spectra was as follows: total sugar(TS)-4 W, nicotine-9 W, total nitrogen(TN)-2 W, ash-8 W, total volatile base(TVB)-5 W, chlorine4 W, L of color-6 W, a of color-6 W and b of color-7 W. Comparing the calibration equations followed by each chemical components, the most precise calibration equation was MPLS for 75, a and b of color, PLS for nicotine, ash, TVB, chlorine and L of color and stepup for TN. The standard error of calibration(SEC) and standard error of performance(SEP) between result of near infrared analysis and standard laboratory analysis were 0.18, 0.40% for 75, 0.06, 0.08% for nicotine, 0.18, 0.16% for TN, 0.33, 0.46% for ash, 0.04, 0.03% for TVB, 0.08, 0.06% for chlorine, 0.54, 0.58 for L of color, 0.22, 0.22 for a of color and 0.27, 0.27 for b of color, respectively. The SEC and SEP of ash and TVB were within allowable error of standard laboratory analysis, nicotine, TN and chlorine were 1.2-2.0 times and 75 were 2.1-4.0 times larger than allowable error of standard laboratory analysis. The ratio of SEC and SEP to mean were 1.5, 1.6% for L of color, 3.7, 3.8% for a of color and 1.8, 1.8% for b of color, respectively. Key words : burley tobacco chemistry, near infrared spectroscopy.

  • PDF

Studies on the Near Infrared Diffuse Reflection Spectroscopy for Meat Components (근적외선 반사분광분석법에 의한 정육 및 그 구성성분의 반사 spectra에 관한 연구)

  • Oh, Eun-Kyong;Grossklaus, Dieter
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.404-407
    • /
    • 1992
  • This study was conducted to determine the effect of the physical and chemical factors on the absorbance when the chemical component of food was rapidly and effectively analyzed with near infrared reflection spectrophotometer. The absorbance was measured within the wavelength range of 1100 and 2500m and at the various sample temperatures. The absorbance was greatly increased with the rising sample temperature. When the grinding time of samples prolonged, the absorbance was decreased. The absorption peaks occurring in the near infrared spectra of meat, meat protein, pork fat and water were attributed to the overtone and combination vibration of C-H, N-H, O-H or C=O bond within the macromolecules of each sample. The absorbance was lower for meat protein than other meat components. Pork fat was characterized by the ${\cdot}CH_2{\cdot}$ absorption peak at the wavelength of 1700 and 2300 nm and water by the relatively high absorption peak at the wavelength of 1450 and 1930 nm. As a result, the absorbance of near infrared reflection spectrum of meat was affected mainly by fat and water in meat.

  • PDF

Study on characteristics of thin films for reflection of near infrared light (근적외선 반사 박막 특성 연구)

  • Chung, Youn-Gil;Park, Hyun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4121-4124
    • /
    • 2015
  • Near infrared blocking function in energy saving window glass is required. The design, deposition and characteristics of optical thin films for reflection of near-infrared light were studied. The optical thin film is designed as laminated film structure with low refractive index film and high index film. Deposition experiments of $SiO_2$ and $TiO_2$ thin films with designed structure using the RF sputtering method were carried out. The characteristics of the thin film with deposition conditions were analyzed. High-refractive-index thin film of $TiO_2$/low refractive-index thin film of $SiO_2$ and high-refractive-index thin film of $TiO_2$ structure for reflection of near-infrared light was designed to be simulated. Results of simulation showed reflectance of 30% or more in the range from 930nm to 1682nm. Triple layer thin films fabricated with simulated results showed wavelength bands from 930nm to 1525nm for the reflectance of 33% or more.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Classification of Red Wines by Near Infrared Transflectance Spectroscopy

  • W.Guggenbichler;Huck, C.W.;M.Popp;G.K.Bonn
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1516-1516
    • /
    • 2001
  • During the recent years, wine analysis has played an increasing role due the health benefits of phenolic ingredients in red wine [1]. On the other hand there is the need to be able to distinguish between different wine varieties. Consumers want to know if a wine is an adulterated one or if it is based on the pure grape. Producers need to certificate their wines in order to ensure compliance with legal regulations. Up to now, the attempts to investigate the origin of wines were based on high-performance liquid chromatography (HPLC), gas chromatography (GC) and pyrolysis mass spectrometry (PMS) [l,2,3]. These methods need sample pretreatment, long analysis times and therefore lack of high sample throughput. In contradiction to these techniques using near infrared spectroscopy (NIRS), no sample pretreatment is necessary and the analysis time for one sample is only about 10 seconds. Hence, a near infrared spectroscopic method is presented that allows a fast classification of wine varieties in bottled red wines. For this, the spectra of 50 bottles of Cabernet Sauvignon, Lagrein and Sangiovese (Chianti) were recorded without any sample pretreatment over a wavelength range from 1000 to 2500 nm with a resolution of 12 cm$\^$-1/. 10 scans were used for an average spectrum. In order to yield best reproducibility, wines were thermostated at 23$^{\circ}C$ and a optical layer thickness of 3 mm was used. All recorded spectra were partitioned into a calibration and validation set (70% and 30%). Finally, a 3d scatter plot of the different investigated varieties allowed to distinguish between Cabernet Sauvignon, Lagrein and Sangiovese (Chianti). Considering the short analysis times this NRS-method will be an interesting tool for the quality control of wine verification and also for experienced sommeliers.

  • PDF

AKARI INFRARED CAMERA SURVEY OF THE LARGE MAGELLANIC CLOUD

  • Shimonishi, T.;Kato, D.;Ita, Y.;Onaka, T.;AKARI/IRC LMC team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.83-85
    • /
    • 2017
  • We conducted an unbiased near- to mid-infrared imaging and spectroscopic survey of the Large Magellanic Cloud (LMC) as a part of the AKARI Mission Program "Large-area Survey of the LMC" (LSLMC, PI: T. Onaka). An area of about 10 square degrees of the LMC was observed by five photometric bands (3.2, 7, 11, 15, and $24{\mu}m$) and a low-resolution slitless prism ($2-5{\mu}m$, R ~20) equipped with AKARI /IRC. We constructed and publicly released photometric and spectroscopic catalogues of point sources in the LMC based on the survey data. The catalogues provide a large number of near-infrared spectral data, coupled with complementary broadband photometric data. Combined use of the present AKARI LSLMC catalogues with other infrared point source catalogues of the LMC possesses scientific potential that can be applied to various astronomical studies.

Cosmic Infrared Background from the First Stars and Relic H II Regions

  • Ahn, Kyung-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.72.2-72.2
    • /
    • 2011
  • We have performed the first self-consistent, large-scale simulation of cosmic reionization by stellar sources, including the Population III stars that emerged and were hosted by minihalos at very high redshifts (z~40). Based on this result, we calculate the redshifted radiation background from these stars and the relic H II regions which can be observed at near-infrared and infrared regime. Formation of the first stars inside minihalos are quenched by radiative feedback at z~15, while the relic H II regions have much longer lifetime due to the slow recombination rate. Therefore, the radiation output from the relic H II regions, dominated by Lyman alpha photons, will be observed both in the near-infrared and infrared regime. The estimated background from the first stars inside minihalos are still sub-dominant compared to that from stars inside larger halos, however, and thus complementary observations are necessary, such as redshifted 21-cm line observation.

  • PDF

Low Resolution Near-Infrared Stellar Spectra Observed by CIBER

  • Kim, MinGyu;Lee, Hyung Mok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.76.2-76.2
    • /
    • 2016
  • We present near-infrared (0.8 - 1.8 microns) spectra of 63 bright (J_mag < 10) stars observed with Low Resolution Spectrometer (LRS) onboard the rocket-borne Cosmic Infrared Background Experiment (CIBER). Two Micron All Sky Survey (2MASS) photometry information is used to find cross-matched stars after reduction and extraction of the spectra. We identify the spectral types of observed stars by comparing with spectral templates from the Infrared Telescope Facility (IRTF) library. All the observed spectra are consistent with late F to M stellar spectral types, and we identify various infrared absorption lines. As our observations are performed above the Earth's atmosphere, our spectra are free from telluric contamination. Including HST/NICMOS and Cassini/VIMS, the spectral coverage has rarely been achieved in space, and the methods developed here can inform statistical studies with future low-resolution spectral measurements such as GAIA photometric and radial velocity spectrometer.

  • PDF