• 제목/요약/키워드: Near Zone

검색결과 995건 처리시간 0.023초

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.233-239
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water. The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg O$_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg O$_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

  • PDF

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회지
    • /
    • 제28권2호
    • /
    • pp.155-159
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water, The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg$O_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg $O_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

연료노즐 출구에서의 속도 형상에 따른 부상화염 높이 및 화염구조에 관한 수치해석 연구 (A Numerical Analysis of Flame Liftoff Height and Structure with the Variation of Velocity Profiles at the Nozzle Exit)

  • 하지수;김태권;박정
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.21-28
    • /
    • 2008
  • 삼지화염과 포와젤(Poiseuille) 및 균일분포 연료출구 속도에 따른 부상화염의 부상거동 그리고 화염면 부근에서의 연소 유동 특성에 대하여 수치적 해석을 수행하였다. 부상화염에 대한 수치해석으로 기존 연구 결과를 검정하고 화염대 부근에서 구조적 특성을 살펴보며 포와젤 및 균일분포 연료출구속도 조건에서 운동량 유속으로 부상높이를 일반화하여 비교하였다. 또한 화염면 부근에서 속도, 압력, 온도, 화학반응속도 등으로 연소 유동 특성을 분석하고 규명하였다. 특히 중심선을 따른 속도 변화의 경우 노즐에서 화염대 부근까지는 전형적인 비반응제트 유동에 따른 속도 분포를 형성하지만 화염대 직전에서 속도가 급격히 감소하다가 화염대를 지나면서 급격히 증가한 후에 다시 감소하는 현상을 규명하였다. 화염대 전의 유동영역에서는 화염대가 장애물역할을 하다가 화염대를 지나고 나면 유동을 가속시켜주는 역할을 하고 있기 때문이다. 이러한 현상은 기존의 비반응 제트 유동으로 규명하지 못하였던 것이다.

  • PDF

근접영역에서의 IR 탐색기 정보를 이용한 표적적응유도 (Target Adaptive Guidance Using Near-Zone Information from IR Seeker)

  • 엄태윤;김필성
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.113-119
    • /
    • 2002
  • A target adaptive guidance(TAG) algorithm is proposed employing the near-zone signal that can be measured from an infrared seeker. The guidance order is composed of a conventional PNG command and an additional command to be calculable from an additional LOS rate between a hot point of target and a required intercept point. The characteristic of the near-zone signal is similar to that of LOS rate that is inversely proportional to the square of time-to-go. Hence the proposed scheme can be applied to real systems with no estimator for time-to-go. From analysis results on the miss distance with perfect missile and perfect seeker, it follows that the proposed TAG algorithm guarantees missile to be ideally guided to the required intercept point. And it is less affected by the TAG start time and a proportional navigation ratio than other TAG schemes using a LOS rate such as a step bias or a ramp bias.

장애물 외관비가 주변 흐름에 미치는 영향 (The Effects of Obstacle Aspect Ratio on Surrounding Flows)

  • 김재진
    • 대기
    • /
    • 제17권4호
    • /
    • pp.381-391
    • /
    • 2007
  • The characteristics of flow around a single obstacle with fixed height and varied length and width are numerically investigated using a computational fluid dynamics (CFD) model. As the obstacle length increases, flow distortion near the upwind side of the obstacle increases and the size of the recirculation zone behind the obstacle also increases. As the obstacle width increases, the size of the recirculation zone decreases, despite almost invariable flow distortion near the upwind side of the obstacle. Flow passing through an obstacle is separated, one part going around the obstacle and the other crossing over the obstacle. The size of the recirculation zone is determined by the distance between the obstacle and the point (reattachment point) at which both the flows converge. When the obstacle width is relatively large, flows are reattached at the obstacle surface and their recoveries occur. Resultant shortening of the paths of flows crossing over and going around decreases the size of the recirculation zone. To support this, the extent of flow distortion defined based on the change in wind direction is analyzed. The result shows that flow distortion is largest near the ground surface and decreases with height. An increase in obstacle length increases the frontal area fraction of flow distortion around the obstacle. In the cases of increasing the width, the frontal area fraction near the upwind side of the obstacle does not change much, but near the downwind side, it becomes larger as the width increases. The frontal area fraction is in a better correlation with the size of the recirculation zone than the building aspect ratios, suggesting that the frontal area fraction is a good indicator for explaining the variation in the size of the recirculation zone with the building aspect ratios.

Al-Si 용융 도금된 보론강 CO2 레이저 용접부의 미세조직과 기계적 성질에 미치는 핫스탬핑 처리의 영향 (Effect of Hot-Stamping on Mechanical Properties and Microstructures of CO2 Laser Welded Boron Steel coated with Al-Si layer)

  • 오명환;공종판;신현정;권민석;정병훈;강정윤
    • 한국레이저가공학회지
    • /
    • 제16권3호
    • /
    • pp.1-10
    • /
    • 2013
  • In this study, Al-Si coated boron steel(1.2 mm) were laser welded by $CO_2$ laser and hot-stamping was applied to the laser joints. Tensile properties and microstructures of the joints were investigated before and after hot-stamping. Tensile and yield strengths of the as welded specimen similar with base metal and fracture occurred base metal of boron steel. Although, in case of heat treated specimen, fracture occurred fusion zone that Al segregated zone near the bond line. These could be explained by the existence of ferrite, in the Al segregated zone near the bond line and base metal of boron steel. Before hot-stamping, hardness of base metal is lower than fusion zone and heat affected zone in spite of exist Al segregation zone($Fe_3$(Al,Si)). So fracture occurred base metal. Although, after hot-stamping, microstructure of base metal and welds zone transformed to martensite and bainite except in Al segregation zone near the bond line that $Fe_3$(Al,Si) transformed to a-ferrite. So fracture occurred Al segregation zone near the bond line.

  • PDF

헤드셋을 이용한 승용차 실내 저소음 영역의 생성 (Formation of the Quiet Zone in an Automobile using Headset)

  • 이철;김인수;홍석윤
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.301-310
    • /
    • 1997
  • This paper presents active noise control method to form the near-field quiet zone for passengers in an automobile. The actuator model including interior acoustic plant, speaker and amplifier is experimentally identified in forms of auto-regressive and moving average by means of least mean square algorithm, The digital controller is composed of the regulator and Kalman filter to be designed based on LQG (linear quadratic gaussian). If the actuator model is prefiltered with digital filter to be properly designed for concentrating control performance index on the frequency band of primary noise source, LQG design approach can be effectively applied for the design of headset controller. Experimental results demonstrate that near-field quiet zone showing about 10dB noise reduction at microphone position can be formed using the headset located at passenger seat.

  • PDF

미세중력장 CdTe 흘로우팅존 생성에서 결정체-용융액 계면주위의 열응력 (Thermal Stresses Near the Crystal-Melt Interface During the Floating-Zone Growth of CdTe Under Microgravity Environment)

  • 이규정
    • 한국전산유체공학회지
    • /
    • 제3권1호
    • /
    • pp.100-107
    • /
    • 1998
  • A numerical analysis of thermal stress over temperature variations near the crystal-melt interface is carried out for a floating-zone growth of Cadmium Telluride (CdTe). Thermocapillary convection determines crystal-melt interfacial shape and signature of temperature in the crystal. Large temperature gradients near the crystal-melt interface yield excessive thermal stresses in a crystal, which affect the dislocations of the crystal. Based on the assumption that the crystal is elastic and isotropic, thermal stresses in a crystal are computed and the effects of operating conditions are investigated. The results show that the extreme thermal stresses are concentrated near the interface of a crystal and the radial and the tangential stresses are the dominant ones. Concentrated heating profile increases the stresses within the crystal, otherwise, the pulling rate decreases the stresses.

  • PDF

TMCP 고장력강 용접부의 하한계 피로균열진전 특성평가 (The characteristics of Near-thrshold fatigue crack propagation for welding zone in TMCP high strength steels)

  • 이택순;오대석;이휘원
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.39-47
    • /
    • 1997
  • Recently developed TMCP steels, which were manufactured by controlled rolling followed by accelerated cooling process, were examined to study their characteristics and weldability. Accelerated cooling type TMCP steel's hardness test result exhibited high value on weld zone. On the contrary, base metal and HAZ exhibited comparatively the similar value. On this experiment result Softening of HAZ is not occurred. in the-heat affected zone, grain size repression be caused by chemical composition properties which a small quantity Al-Ti-B-N. Changing stress ratio near-threshold fatigue crack propagation experiments were carried out. According to this result, crack propagation velocity of the HAZ exhibited slower than the base metal and near-threshold value had increased at the HAZ. Finally accelerated cooling type TMCP steels were exhibited excellent mechanical properties in both strength and toughness.

  • PDF

충북의 2010년 이후 신설된 학교 분석을 통한 저층부 배치 시설 및 공간 특성 연구 (A Study on the Facilities Layout of Lower Floor and Space Characteristics Through Analysis of Newly Established Schools in Chungbuk since 2010)

  • 강혜진;정진주
    • 교육시설 논문지
    • /
    • 제22권2호
    • /
    • pp.3-13
    • /
    • 2015
  • The policy of the Ministry of education through the social awareness and issues are being changed. Accordingly, in response to the school building which also has to be changed. This study is Low-floor(1~2 floor) for high accessibility, important management and a lot of locomotion. This study is analysis by floor of newly established schools in Chungbuk. Facility and space on the possible low-floor situated are classified administrative zone, health zone, student support + local exchange zone, STEAM(creativity, personality) supporting zone. The administrative area includes administration office, principal's office and board rooms. The administrative zone is located against schoolyard. Because it is possible visual control of schoolyard. also it controls visitor access so it is placed near main entrance. Health zone is located near a special class, counseling center and wee class for emergency situation. and is located near schoolyard for visual control. Student support + local exchange area includes library and computer lab, audio-visual room, auditorium or gymnasium. It put more emphasis resident welfare, culture and education. So it opens for local residents. It is located center of few stories or near entrance. STEAM(creativity, personality) supports science lab, art room, family room. It is possible such a theory class, experience class and indoor and outdoor class. It is located few floors. This study is used as a reference for school building projects planing.