• 제목/요약/키워드: Near Infrared Reflectance Spectroscopy

검색결과 214건 처리시간 0.027초

Nondestructive Determination of Humic Acids in Soils by Near Infrared Reflectance Spectroscopy

  • Seo, Sang-Hyun;Park, Woo-Churl;Cho, Rae-Kwang;Xiaori Han
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.31-35
    • /
    • 2000
  • Near-infrared reflectance spectroscopy(NIRS) was used to determine the humic acids in soil samples from the fields of different crops and land-use over Youngnam and Honam regions in Korea. An InfraAlyzer 500 scanning spectrophotometer was obtained near infrared relectance spectra of soil at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of humic acid, fulvic acid and its total contents in soils. The raw spectral data(log 1/R) can be used for estimating humic acid, fulvic acid and its total contents in soil by MLR procedure between the content of a given constituent and the spectral response of several bands. In which the predicted results for fulvic acid is the best in the constituents. The new spectral data are converted from the raw spectra by PLSR method such as the first derivative of each spectrum can also be used to predict humic acid and fulvic acid of the soil samples. A low SEC, SEP and a high coefficient of correlation in the calibration and validation stages enable selection of the best manipulation. But a simple calibration and prediction method for determining humic acid and fulvic acid should be selected under similar accuracy and precision of prediction. NIRS technique may be an effective method for rapid and nondestructive determination for humic acid, fulvic acid and its total contents in soils.

근적외선 분광분석을 통한 산무수물경화 에폭시 시스템의 경화 동력학 (Cure Kinetics for the Acid Anhydride-cured Epoxy System Using a Near-infrared Reflection Spectroscopy)

  • 곽근호;박수진;이재락
    • 폴리머
    • /
    • 제24권1호
    • /
    • pp.65-71
    • /
    • 2000
  • 산무수물 경화 에폭시 수지의 잠재 특성 및 경화 동력학을 근적외선 분광분석법을 통해서 논의하였다. 잠재 특성과 경화 거동의 확인은 각기 다른 온도에서 에폭사이드와 수산기의 NIR reflectance를 측정함으로써 행해졌으며 반응 과정에서 4000~7100$cm^{-1}$ / 스펙트럼 범위의 주된 NIR 흡수피크의 기점, 위치 그리고 전이에 대한 포괄적인 분석이 이루어졌다. 반응의 정도는 에폭사이드의 함량과 경화 온도에 의존적인 4530$cm^{-1}$ /의 NIR 흡수 피크로부터 결정하였다.

  • PDF

Nondestructive determination of humic acid in compost by NIRS

  • Seo, Sang-Hyun;Han, Xiao-Ri;Cho, Rae-Kwang;Park, Woo-Churl
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1623-1623
    • /
    • 2001
  • Composting is a biological method used to transform the organic waste into stable, humified organic amendments. Humification is indicated as the key factor in improving the quality of compost, because of the importance of humic substances to soil ecology, fertility and structure, and their beneficial effects on plant growth The compost constituents vary widely, however, the degree of maturity is very important factor in compost quality. So this experiment carried out to determine the rapid estimation of the quality in cattle, pig, chicken and waste composts using near infrared reflectance spectroscopy(NIRS). Near infrared reflectance spectra of composts was obtained by Infra Alyzer 500 scanning spectrophotometer at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of humic acid contents in composts. The results summarized that NIR spectroscopy can be used as a routine testing method to determine quantitatively the humic acid content in the compost samples ondestructively. Especially, we supposed that absorbance around 2300nm is related to humic acid as a factor of compost maturity. However the NIR absorption approach is empirical, it actually requires many combinations of samples and data manipulations to obtain optimal prediction.

  • PDF

CALIBRATION TRANSFER FROM REFLECTANCE TO INTERACTANCE-REFLECTANCE WITHOUT STANDARDS: USE OF MATHEMATICAL PRETREATMENTS

  • Fernandez Cabanas, Victor-M.;Varo, Garrido;Dardenne, Pierre
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1242-1242
    • /
    • 2001
  • The use of fibre optic probes for NIR quality control in the industry is becoming very important, as it provides a powerful tool to reduce sample analysis time and it facilitates the implementation of on-line analyses. However, most of the applications of fibre optics and probes have been done on suspensions, clear liquids and films, chemical and pharmaceutical products and also on fruits and animal products. Traditional applications of near infrared spectroscopy in agriculture have been developed in reflectance mode and calibration transfer could be an interesting way to reduce efforts. Classical methods for calibration transfer between different instruments involve the use of sealed reference cups, but, as fibre optic analysis does not use cups, it is necessary to develop new methods for calibration transfer without standards (Blank et al., 1996). In this paper, we have studied how the most used mathematical pretreatments (three methods of Multiplicative Scatter Correction, Standard Normal Variate, Detrending and derivatives) and their combinations applied to calibration development can contribute to reduce spectral differences between instruments. Calibration equations were obtained for three sets of cereals (barley, wheat and maize) scanned in reflectance mode and then they were validated with samples analysed in reflectance and interactance-reflectance mode (fibre optic). Preliminary results show how some combination of pretreatments reduce the differences in the predicted values, measured as standard error of differences, facilitating the use of calibrations obtained in reflectance for samples analysed by interactance-reflectance. However, the application of pretreatments is not enough to satisfy the control limits for calibration transfer suggested by Shenk et al. (1992), and it should be necessary to combine them with a specific algorithm for instruments standardization.

  • PDF

Analysis of Protein and Moisture Contents in Pea(Pisum sativum L. Using Near-Infrared Reflectance Spectroscopy

  • Jung, Chan-Sik;Kim, Byung-Joo;Kwon, Yil-Chan;Han, Won-Young;Kwack, Yong-Ho
    • 한국작물학회지
    • /
    • 제43권2호
    • /
    • pp.101-104
    • /
    • 1998
  • This study was conducted to establish a rapid analysis method for determining protein and moisture contents of pea. Ninety and eighty pea (Pisum sativum L.) lines were analyzed to determine protein and moisture contents, respectively using near-infrared reflectance spectroscopy. Simple correlations (${\gamma}$) of protein content in a ground sample and an intact grain sample by an automatic regression method were 0.978 and 0.910, respectively. Simple correlations by partial least square regression/principal component analysis (PLS/PCA) methods were 0.982 and 0.925, respectively. Standard error of performance (SEP) in protein content was the lowest value, 0.446 in ground sample by PLS/PCA methods. Simple correlation of moisture content was the highest at 0.871 in ground samples. when using a standard regression method. Accuracy for the moisture content was slightly lower than for protein content. It was concluded that the NIRS method would be applicable only for rapid determination of protein content in pea.

  • PDF

Determination of Protein Content in Pea by Near Infrared Spectroscopy

  • Lee, Jin-Hwan;Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.60-65
    • /
    • 2009
  • Near infrared reflectance spectroscopy (NIRS) was used as a rapid and non-destructive method to determine the protein content in intact and ground seeds of pea (Pisum sativum L.) germplasms grown in Korea. A total of 115 samples were scanned in the reflectance mode of a scanning monochromator at intact seed and flour condition, and the reference values for the protein content was measured by auto-Kjeldahl system. In the developed ground and intact NIRS equations for analysis of protein, the most accurate equation were obtained at 2, 8, 6, 1 math treatment conditions with standard normal variate and detrend scatter correction method and entire spectrum (400-2,500 nm) by using modified partial least squares regression (n=78). External validation (n=34) of these NIRS equations showed significant correlation between reference values and NIRS estimated values based on the standard error of prediction (SEP), $R^2$, and the ratio of standard deviation of reference data to SEP. Therefore, these ground and intact NIRS equations can be applicable and reliable for determination of protein content in pea seeds, and non-destructive NIRS method could be used as a mass analysis technique for selection of high protein pea in breeding program and for quality control in food industry.

근적외선 분광분석법을 이용한 생약의 원산지 판별 (Discrimination of Herbal Medicine According to Geographical Origin (Korea, China) Using Near Infrared Reflectance Spectroscopy)

  • 우영아;조창희;김효진;조정환;조경규;정승성;김수정;김중환
    • 약학회지
    • /
    • 제42권4호
    • /
    • pp.359-363
    • /
    • 1998
  • Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China) of herb drugs. Herbal medicine has an important role in clinical therapy in Asian countries such as Korea and China. The objective of this study is to provide a convenient and accurate method to determinate geographical origin (Korea, China) of herbal medicine for quality control whose quality is generally different according to geographical origin. A rapid, nondestructive and accurate discrimination was achieved by NIRS. Second derivative spectra of herb drugs were subjected to discriminant analysis. Herbal medicine drugs such as Cassia Semen, Ganoderma and Smilacis Rhizoma was discriminated accurately according to geographical origin using PLS regression method.

  • PDF

FAST QUANTITATIVE AND QUALITATIVE ANALYSIS OF PHARMACEUTICAL TABLETS BY NIR

  • Nielsen, Line-Lundsberg;Charlotte Kornbo;Mette Bruhn
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3111-3111
    • /
    • 2001
  • The implementation of NIR and chemometrics in the Pharmaceutical industries is still in strong progress, both regarding qualitative and quantitative applications and beneficial results are seen. Looking at the development so far, NIR will change the pharmaceutical industry even more in the future. This presentation will address the experiences and progress achieved regarding the application and implementation of quantitative methods for determination of content uniformity and assay of tablets with less than 10% w/w of active, using Near Infrared transmittance spectroscopy in combination with PLS. Also qualitative methods for identification of the same tablets by Near Infrared reflectance spectroscopy will be discussed. Four commercial tablet strengths are formulated and produced from two different compositions by direct compression. Three different strengths are dose proportional, i.e. fixed concentration by varying in size. The aim was to replace the conventional primary methods for analysing content uniformity, assay and identification by NIR. Studies were performed on comparing transmittance versus reflectance spectroscopy for both applications on the dose proportional tablets. The model for determination of content uniformity and assay was developed to cover both coated and uncoated tablets, whereas the qualitative model was developed to identify coated tablets only. The impact of the tablet formulation, tablet size and coating, resulted in individual models far each composition The best calibration was achieved using diffuse reflectance for the identification purposes and diffuse transmittance for the quantitative determination of the active content within the tablets. As NIR in combination with other techniques opens up the possibility of total quality management within the production, the transfer of the above-mentioned models from a laboratory based approach to an at-line approach at H.Lundbeck will be addressed too.

  • PDF

Discrimination of geographical origin and cultivation years of Ginseng by near Infrared reflectance spectroscopy

  • Lin, Guo-Lin;Sohn, Mi-Ryeong;Cho, Rae-Kwnag;Hong, Jin-Hwan
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.41-44
    • /
    • 2000
  • The objectives of this study are to discriminate the geographical origin and cultivation years of ginseng based on the near-infrared(NIR) reflectance spectroscopic analysis. Korea and China ginseng samples were prepared for discrimination of geographical origin. 4, 5 and 6 years-old ginseng samples from Korea were prepared for discrimination of cultivation years. Used spectrometer were InfraAlyzer 500, InfraAlyzer 400 and Fiber optic. Sample type of ginseng was 3, whole ginseng radix, slide section and powder type. The accuracy was affected by sample types and instruments. The accuracy for discrimination geographical origin was 97% in calibration model using IA 500 and ginseng powder. For discrimination of cultivation years, the model with slide selection using IA500 were relative accurate. The accuracy was 96.7% for 4-year, 91.3% for 5-year and 89.3% for 6-year old ginseng. The study shows that NIR spectroscopic analysis can be used to discriminate the geographical origin and cultivation years of ginseng with acceptable accuracy.

NEAR INFRARED BIO-SPECTROSCOPY : APPROACHES FOR MEASUREMENTS IN CRITICAL CARE

  • Burns, David
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.2102-2102
    • /
    • 2001
  • Near infrared, diffuse reflectance spectroscopy has shown significant potential for in vitro and in vivo assessment of metabolic status. However, the complexity of living samples can lead to ambiguous results. This presentation will focus on methods that provide controls for scattering and absorption estimation in tissue. For robust estimations, normalization procedures will be shown which can greatly improve interpretability of results. Normalization based on time, location and spectral property will be shown with data from models, tissue phantoms and in vivo measurements. In particular, interpretation of NIR spectra associated with major respiratory constituents will be examined. Measurement of constituents such as hemoglobin, myoglobin, tissue edema, and lactate will be shown. Results suggest that NIR may provide a valuable tool for physiological monitoring in critical care research and practice.

  • PDF