• Title/Summary/Keyword: Near Infrared Lamp

Search Result 22, Processing Time 0.033 seconds

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

Evaluation of illuminant effect of NIR(Near Infrared Radiation) using spectrophotometer for medicine (의학용 분광광도계를 이용한 근적외선 대역의 조명 영향평가)

  • Lee, Sangsik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.16-22
    • /
    • 2010
  • In this paper, we evaluated the effect with respect to the light of 700-1,100 nm NIR(near infrared radiation) for spectrophotometer. Standard, red, yellow, green and blue color paper which was Munsell color paper were used for experiments. Our used light is incandescent lamp, fluorescent lamp, invert fluorescent lamp and combined lamp. Each color paper was measured 20 times. Therefore we concluded that it is possible to build a spectrophotometer for NIR(near infrared radiation) measurement we applied an spectrophotometer to measurement system in incandescent lamp.

  • PDF

A study on the Drying Characteristics of NIR Dryer (근 적외선 건조기의 건조특성에 대한 연구)

  • Jang, Yeong-Suk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • Near Infrared Ray (NIR) are primarily of interest to the high energy physicist. It is the intermediate portion of the spectrum, which extends from approximately 0.8 to 1.5 ${\mu}m$ and include a portion of the all of infrared, that is thermal radiation and is pertinent to heat transfer. It is important to study that temperature distribution of the drying materials by surface encompasses a range of NIR wave lengths. This study is to investigate the characteristics of NIR dryer by experimental results. it was made a comparison with various textiles, velocity ratio and distance of lamp and textiles. In case of spongy type textile the drying performance is the superior of all. The 0.15m distance drying effect of improvement 30% more than 0.26m distance between lamp and textiles. As the contained water increases, the drying speed for textile can be increased.

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

Novel optical properties of amorphous ferric hydroxide in near infrared region

  • Kang, Tae Yeon;Chae, Weon-Sik
    • Rapid Communication in Photoscience
    • /
    • v.4 no.2
    • /
    • pp.34-36
    • /
    • 2015
  • New spectroscopic characteristics of amorphous ferric hydroxide ($Fe(OH)_3$), interestingly in the near infrared (NIR) region, are presented in this study. The absorption spectrum of ferric hydroxide covers wide spectral regions from ultraviolet to NIR (200~900 nm). Unique emission bands were newly observed in the NIR regions (800~1400 nm). Several bands of this NIR emission are quiet well overlapped with the combinational vibrational absorption bands of water. From photothermal conversion study, very interestingly, temperature of aqueous mixture solution including the amorphous ferric hydroxide was significantly increased from ambient temperature to $38^{\circ}C$ for 30 minutes under irradiation of a standard helium lamp.

Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System (휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정)

  • 강나루;우영아;차봉수;이현철;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

A Computational Study on the Cooling Performance of a Near Infrared Radiative Heating System (근적외선 가열 시스템의 냉각 성능에 대한 수치적인 연구)

  • Yoo, Keun-Pyo;Han, Minsub;Kim, Jae-Duck;Choi, Won-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.289-296
    • /
    • 2013
  • A near infrared (NIR) heating system has advantages over the conventional convection-based systems, in terms of heating uniformity and energy efficiency. When it is over-heated during its operation, the radiation lamp gets blackened, and the life of the radiation module becomes severely limited. The heat transfer system in the module is based on a high operating-temperature, and the radiation makes it difficult to analyze in detail the reliability issue, with an experimental approach alone. We developed a numerical heat-transfer model of the NIR heating system. We applied a ray-tracing method on the radiative heat transport, and a finite volume method on the conductive and convective systems, respectively. The cooling performance of the system is presented, based on the energy and flow distributions in the module. The factors that directly affect the module life are analyzed, such as the surface temperatures of the lamp glass and the reflector, and design improvements are discussed.

Monitoring of Environmental Arsenic by Cultures of the Photosynthetic Bacterial Sensor Illuminated with a Near-Infrared Light Emitting Diode Array

  • Maeda, Isamu;Sakurai, Hirokazu;Yoshida, Kazuyuki;Siddiki, Mohammad Shohel Rana;Shimizu, Tokuo;Fukami, Motohiro;Ueda, Shunsaku
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.12
    • /
    • pp.1306-1311
    • /
    • 2011
  • Recombinant Rhodopseudomonas palustris, harboring the carotenoid-metabolizing gene crtI (CrtIBS), and whose color changes from greenish yellow to red in response to inorganic As(III), was cultured in transparent microplate wells illuminated with a light emitting diode (LED) array. The cells were seen to grow better under near-infrared light, when compared with cells illuminated with blue or green LEDs. The absorbance ratio of 525 to 425 nm after cultivation for 24 h, which reflects red carotenoid accumulation, increased with an increase in As(III) concentrations. The detection limit of cultures illuminated with near-infrared LED was 5 ${\mu}g$/l, which was equivalent to that of cultures in test tubes illuminated with an incandescent lamp. A near-infrared LED array, in combination with a microplate, enabled the simultaneous handling of multiple cultures, including CrtIBS and a control strain, for normalization by the illumination of those with equal photon flux densities. Thus, the introduction of a near-infrared LED array to the assay is advantageous for the monitoring of arsenic in natural water samples that may contain a number of unknown factors and, therefore, need normalization of the reporter event.

Development of preheating technology on energy-saving extrusion dies applying infrared lamp (근적외선 램프를 적용한 에너지 절감형 압출금형 예열기술 개발)

  • Min, Kyung-Ho;Bae, Seong-Hwan;Choi, Ho-Joon;Shin, Young-Chul
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • The aim of this study is to develop the dies oven for energy-saving during the pre-heated process of extrusion dies. Applying high-efficiency near-infrared heater, single cell type dies oven was developed as a substitute for traditional chest type oven. Therefore the dies is individually heated uniformly to operation temperature so rapidly. By using the developed dies oven, electric-energy consumption of preheating extrusion dies reduced up to 30% and the waiting time in the oven also minimized up to 90min. In addition, the results have shown that it is possible to accurately control the dies temperature for improving the quality of extruded profile and to minimize die bearing oxidation and nitride layer degradation responsible for surface defects on the profile and shorter die life.