• Title/Summary/Keyword: Nd.YAG 레이저

Search Result 777, Processing Time 0.026 seconds

Stimulated Raman scattering at 1.54${\mu}m$ and Brillouin scattering at 1.06${\mu}m$ in $CH_4$ under 5 Hz repetition rate (반복률과 라만매질 압력에 따른 1.54 ${\mu}m$ 전방, 후방 유도라만 및 1.06${\mu}m$ Brillouin 산란광의 출력특성)

  • 최영수;전용근;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • We have studied the 1.54$\mu\textrm{m}$ forward and backward stimulated Raman scattering (SRS) and stimulated Brillouin scattering (SRS) for various $CH_4$pressures by 1.06$\mu\textrm{m}$ Q-switched Nd:YAG laser pumping under a repetition rate of Hz in single pass. We obtained that the output of backward SRS was more efficient than that of the forward SRS. The output energy and conversion efficiency of forward and backward SRS were higher than those of SBS since SRS is a steady state, but SBS is a transient state. In a $CH_4$gas uncirculating system, the output energy of the backward SRS and SBS were reduced the about 47% due to a thermal heating of $CH_4$medium in a focusing region for a repetition rate of 5 Hz. But, the output energy of forward SRS was slightly enhanced by about 8.5% due to the increase of the undepleted pump beam in the backward SRS generation. Inthe Raman half resonator using a dichromatic focusing lens, the conversion efficiency of SRS was more than 37% for a input pump laser energy of 40 mJ.

  • PDF

Percutaneous Laser Discectomy in Lumbar Disc Herniation -A case report- (요추간판 탈출증에서 레이저를 이용한 경피적 추간판절제술 -증례 보고-)

  • Kim, Won-Oak;Yoon, Duck-Me;Jang, Won-Suck;Oh, Kyung-Me;Kim, Hyo-Eun
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.234-238
    • /
    • 2001
  • Percutaneous laser discectomy has potential advantages over conservative therapy and classical open surgery as a minimally invasive procedure, although clinical experiences are limited. We experienced a patient treated with herniated lumbar discs using Nd:YAG laser. A 55-year-old woman complained of severe back pain with sciatica on L4/5 and L5/S1 dermatome for several months. The MRI finding showed bulging discs at L4/5 and L5/S1. Epidural, transsacral and root block treatments were attempted without effect. Under fluoroscopic guidance, a 14 G biopsy needle was inserted into the L4/5 and L5/S1 disc spaces to the margin of the nucleus pulposus. Laser irradiation for vaporization of tissue was performed at 20 W/second to 1200 J. A laser fiber ($600{\mu}m$) was advanced 1 cm from the tip of the needle. At the end of the procedure, the patient began to feel relief of pain (VAS changed from 9 to 4) and was discharged the same day after staying 2 hours in the recovery room. Antibiotics were administered for prevention of discitis. She had no complaints of pain until the 1-month follow up visit. Percutaneous laser discetomy technique has the disadvantages of expensive equipment, high temperature and amount of vaporing disc tissue is empirical. However, this technique, as one of the therapeutic modalities for disc herniation, provides faster relief from acute attack than conservative management techniques in carefully selected patients with sciatica due to disc prolapse.

  • PDF

Synthesis and Properties of Hyperbranched Polyester with Second-Order Outical Nonlinearity (2차 비선형 광학 초분지형 폴리에스테르의 합성 및 특성)

  • 이종협;이광섭
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.803-810
    • /
    • 2001
  • A nonlinear optical hyperbranched polyester (PE-Azo/Hyper) was synthesized from 4-[N,N-bis(hydroxyethyl)amino-4'-formyl] azobenzene and cyanoacetic acid by a Knoevenagel polycondensation using 4-(dimethylamino) pyridine as a base. The resulting polymer was soluble in polar aprotic solvents such as N,N-dimethylformamide and 1-methyl-2-pyrrolidinone and could be processed into optical quality films by spin coating. The molecular weight was determined to be $M_w$=61,800 ($M_W/M_n{=1.86}$) by gel permeation chromatography using polystyrene as a standard. No melting point was detected by differential scanning Calorimeter, indicating that this polymer presents an amorphous state. It shows a glass transition temperature of $121^{\circ}C$. The second-order nonlinear optical coefficient $d_{33}$ of the poled polymer determined by the second harmonic generation at 1064 nm was 25.4 pm/V.

  • PDF

Improvement of Tribological Characteristics of Multi-Scale Laser-Textured Surface in terms of Lubrication Regime (윤활영역에서 멀티크기 Laser Surface Texturing 효과)

  • Kim, Jong-Hyoung;Choi, Si Geun;Segu, Dawit Zenebe;Jung, Yong-Sub;Kim, Seock-Sam
    • Tribology and Lubricants
    • /
    • v.30 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Laser Surface Texturing(LST) is a surface engineering process used to improve tribological characteristics of materials by creating patterned microstructures on the mechanical contact surface. In LST technology, a pulsated laser beam is used to create arranged dimples on a surface by a material ablation process, which can improve such as load capacity, wear resistances, lubrication lifetime, and reduce friction coefficients. In the present study, the effect of multi-scale LST on lubricant regime was investigated. A pulsed Nd:YAG laser was applied on the bearing steel(AISI 52100) to create arranged dimples. To optimize the surface texturing effect on friction, multi-scale texture dimples with some specific formula arrays were fabricated by combining circles, ellipses and the laser ablation process. The tribological testing of multi-scale textured surface was performed by a flat-on-flat unidirectional tribometer under lubrication and the results compared with that of the non-textured surface. Through an increase in sliding speed, the beneficial effect of multi-scale LST performance was achieved. The multi-scale textured surface had lower friction coefficient performances than the non-textured surface due to the hydrodynamic lubrication effect.

Fabrication of High Tunable BST Thin Film Capacitors using Pulsed Laser Deposition (펄스 레이저 증착법에 의한 BST 박막 가변 Capacitors 제작)

  • Kim, Sung-Su;Song, Sang-Woo;Roh, Ji-Hyoung;Kim, Ji-Hong;Koh, Jung-Hyuk;Moon, Byung-Moo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.79-79
    • /
    • 2008
  • We report the growth of $Ba_{0.5}Sr_{0.5}TiO_3$(BST) thin films and their substrate-dependent electrical characteristics. BST thin films were deposited on alumina(non-single crystal), $Al_2O_3$(100) substrates by Nd:YAG Pulsed Laser Deposition(PLD) with a 355nm wavelength at substrate temperature of $700^{\circ}C$ and post-deposition annealing at $750^{\circ}C$ in flowing $O_2$ atmosphere for 1hours. BST materials had been chosen due to high dielectric permittivity and tunability for high frequency applications, To analyze the oxygen partial pressure effects, deposited films at 1, 10, 50, 100, 150, 200, 300 mTorr. The effects of oxygen pressure on structural properties of the deposited films have been investigated by X-ray diffraction(XRD) and atomic force microscope(AFM), respectively. Then we manufactured a inter-digital capacitor(IDC) patterns twenty fingers and $10{\mu}m$ gap, $700{\mu}m$ length and electrical properties were characterized. The results provide a basis for understanding the growth mechanisms and basic structural and electrical properties of BST thin films as required for tunable microwave devices applications such as varactors and tunable filters.

  • PDF

A Case of Tracheal Hemangioma Manifested Massive Hemoptysis (대량객혈을 보인 기관 혈관종 1예)

  • So, Soon-Chan;Kwack, Kyung-Kunn;Park, Hae-Kyu;Kim, Jong-Hyung;Shin, Hyun-Min;Lyu, Doo-Yuel;Lee, Duck-Kee;Shin, Yuoon;Kim, Seok-Eun;Park, Young-Hye;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.704-708
    • /
    • 1999
  • Hemangioma is benign tumor that represent an fail in development of the vascular system, network or retiform stage. As with hemangioma elsewhere, spontaneous regression may occur. Histologically capillary hemangioma has a diagnostic lobular arrangement of capillaries and almost all of them are located in nasal or oral mucous membranes. But, as we know, there is no report of hemangioma located in the trachea in Korea, so we report a case of tracheal hemangioma which was manifested massive hemoptysis.

  • PDF

Spray Characteristics of the Injector for the APU Gas Tubine Engine at Airplane Operating Conditions (항공기 작동조건에 따른 APU 가스터빈엔진 연료노즐의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2008
  • Spray characteristics for APU gas turbine engine are investigated. In the test, four flight conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power are used as spray experimental conditions. Spray visualization was performed by using ND-YAG laser bean PDPA(Phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity from 20 mm to 100 mm from discharge orifice. From the test result, SMD is $90{\sim}95\;{\mu}m$ 맛 20,000 ft idle condition and SMD is $60{\sim}75\;{\mu}m$ at sea level idle condition. Also SMD is $55{\sim}65\;{\mu}m$ at 20,000 ft max power condition and SMD is $30{\sim}70\;{\mu}m$ at sea level max power condition. In the case of 20,000 ft idle condition, combustion instability could be occurred due to the higher drop diameter. Therefore it is necessary to decrease the droplet diameter in the high altitude condition.

고성능 투명박막트랜지스터 Source/Drain용 AZO박막 특성연구

  • Park, On-Jeon;No, Ji-Hyeong;Park, Jae-Ho;Sin, Ju-Hong;Jo, Seul-Gi;Yeo, In-Hyeong;Mun, Byeong-Mu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.357-357
    • /
    • 2012
  • 박막트랜지스터의 전극으로 Au, Ag, Mo, ITO와 같은 물질들이 이미 많이 연구되어 왔으며, 투명 Source/Drain 전극을 활용한 물질로는 ITO에 초점이 맞춰져 왔다. 하지만 ITO의 높은 가격과 Indium의 인체 유해한 독성 때문에 ITO를 대체하는 물질에 대해 많은 연구가 진행되고 있다. 그 중 Al이 도핑된 ZnO (AZO) 는 가시광 영역에서 85% 이상의 높은 투과율과 높은 전도성, 낮은 비저항으로 다양한 광전소자의 전극과 윈도우 물질로 많은 응용 가능성을 보여주고 있다. 본 실험에서는 고 품질의 박막성장이 가능하고, 박막의 두께를 세밀하게 조절할 수 있는 Pulsed Laser Deposition (PLD) 을 이용하여 온도변화에 따라 AZO 박막을 성장시키고 구조적, 전기적, 광학적 특성을 조사하였다. 또한 온도변화가 AZO 박막 특성에 미치는 영향을 분석하여 Source/Drain 전극으로 사용하기 위한 조건을 최적화하였고, 실제 투명박막트랜지스터 제작을 통해 소자의 I-V Curve 와 Transfer 특성을 확인하고, Transfer Length Method 방법을 이용하여 투명박막트랜지스터의 접촉저항, 채널 비저항 등을 확인해 보았다. 소결된 타겟으로는 99.99%의 순도를 갖는 ZnO-$Al_2O_3$ (98:2 wt%) 타겟을 이용하였으며, 장비조건으로는 355 nm의 파장대역을 갖는 Nd:YAG 레이저를 사용하였고, 실험변수로는 온도범위 RT, $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$에서 실험을 진행하였다. AZO 박막의 구조적, 전기적 특성을 분석하기 위해 각각 X-Ray Diffraction (XRD), Hall measurement 장비를 사용하였으며, 광학적 특성을 분석하기 위한 투과도의 측정은 UV-Visible spectrophotometer 장비를 사용하였다.

  • PDF

Laser Cladding with Al-36%Si Powder Paste on A319 Al Alloy Surface to Improve Wear Resistance (A319 알루미늄 합금 표면에 Al-36%Si 합금분말의 레이저 클래딩에 의한 내마모성 향상)

  • Lee, Hyoung-Keun
    • Journal of Welding and Joining
    • /
    • v.35 no.2
    • /
    • pp.58-62
    • /
    • 2017
  • A319 aluminum alloy containing 6.5% Si and 3.5% Cu as major alloying elements has been widely used in machinery parts because of its excellent castability and crack resistance. However it needs more wear resistance to extend its usage to the severe wear environments. It has been known that hyper-eutectic Al-Si alloy having more than 12.6% Si contains pro-eutectic Si particles, which give better wear resistance and lubrication characteristics than hypo-eutectic Al-Si alloy like A319 alloy. In this study, it was tried to clad hyper-eutectic Al-Si alloy on the surface of A319 alloy. In the experiments, Al-36%Si alloy powder was mixed with organic binder to make a fluidic paste. The paste was screen-printed on the A319 alloy surface, melted by pulsed Nd:YAG laser and alloyed with the A319 base alloy. As experimental parameters, the average laser power was changed to 111 W, 202 W and 280 W. With increasing the average laser power, the melting depth was changed to $142{\mu}m$, $205{\mu}m$ and $245{\mu}m$, and the dilution rate to 67.2 %, 72.4 % and 75.7 %, and the Si content in the cladding layer to 16.2 %, 14.6 % and 13.7 %, respectively. The cross-section of the cladding layer showed very fine eutectic microstructure even though it was hyper-eutectic Al-Si alloy. This seems to be due to the rapid solidification of the melted spot by single laser pulse. The average hardness for the three cladding layers was HV175, which was much higher than HV96 of A319 base alloy. From the block-on-roll wear tests, A319 alloy had a wear loss of 5.8 mg, but the three cladding layers had an average wear loss of 3.5 mg, which meant that an increase of 40 % in wear resistance was obtained by laser cladding.

EFFECT OF LASER IRRADIATION ON DENTIN SURFACE STRUCTURE AND SHEAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER. (상아질 표면 구조와 광중합형 글라스 아이오노머의 전단강도에 대한 레이저 조사의 효과)

  • Park, Mi-Ryoung;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.76-92
    • /
    • 1998
  • The purpose of this study was to evaluate the possible efficacy of Nd-YAG laser as a dentin conditioner by observing the laser irradiation dentin surface under scanning electron micrograph and measuring shear bond strength of restored light-cured glass ionomer mold. Fifty intact premolars were prepared for shear bond strength tests. The teeth were randomly divided into five groups as follows; Group I. no treatment Group II. 10% poly acrylic acid, 20 sec Group III. laser treatment 2 w, 20 Hz, 2 sec Group IV. laser treatment 2 w, 20 Hz, 5 sec Group V. laser treatment 2 w, 20 Hz, 10 sec Samples of each group were restored with light-cured glass ionomer cement after dentin conditioning and then measuring the shear bond strength of each specimen were measured using universal testing machine. Additional ten premolars were prepared for SEM analysis The result from the this study can be summarized as follows. 1. Shear bond strength of polyacrylic acid-treated group (II) was significantly higher than other groups (p<0.05). 2. No statistically significant difference could be found between three laser-treated groups (III, IV, V) in shear bond strength(p>0.05) 3. According to the result of observation under SEM, Polyacrylic acid was shown to have removed the smear layer effectively and opened the dentinal tubules, whereas the laser has produced the irregular surface mainly composed of melted and fused structure. The microcracks found in laser-treated groups increased in number with irradiation time and formed the regular mesh-type in 10 sec-irradiation group. 4. The ultrastructural change of dentin surface created by laser irradiation was found to the improper for bonding of the glass ionomer restorative materials. And the lower shear bond strength of laser irradiated group might have been due to the failure to form the suit able dentin surface for the glass ionomer to penetrated into and form the proper micromechanical retention.

  • PDF