• Title/Summary/Keyword: Nd-YAG pulsed laser

Search Result 276, Processing Time 0.027 seconds

A Study on the Butt Welding of Zircaloyf Sheets Using Nd:YAG Laser (Nd-YAG 레이저를 이용한 Zircaloy-4 판재의 맞대기 용접에 관한 연구)

  • 황용화;고진현
    • Proceedings of the KWS Conference
    • /
    • 2000.04a
    • /
    • pp.139-143
    • /
    • 2000
  • Laser beam weldability of Zircaloy-4 was investigated using a pulsed Nd:YAG laser of 550W average power. Mechanical properties and microstructure of laser butt welded Zircaloy-4 test specimens were examined. The influence of laser generated during laser welding was analyzed and optimum laser welding parameters were investigated.

  • PDF

TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY (레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구)

  • Ahn, Hyun-Jeong;Kim, Hyoun-Chull;Choi, Byeong-Gap;Song, Eon-Hee;Kim, Rae-Gyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

Comparison of Output Characteristics of Pulsed Nd:YAG Laser using PFN Method with Multiple-Mesh (다단메쉬 PFN방식 펄스형 Nd:YAG 레이저의 출력특성 비교)

  • Joung, J.H.;Kwak, B.G.;Kim, D.H.;Moon, J.K.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1900-1902
    • /
    • 1997
  • In order to obtain various waveforms of current pulse applied at the flashlamp, we have fabricated a Pulsed Nd:YAG laser by PFN with multiple-mesh formed LC network. we have obtained various waveforms of current pulse by adjusting the values of L and C, compared these waveforms of current pulse with laser beam, and then analyzed the laser output energy. We have got relations for $E_{TH}$ and $E_L$ at each mesh which supplies energy with flashlamp and found that output of Pulsed Nd:YAG Laser for 2-mesh, 5-mesh coincided with computer's simulation, PSPICE.

  • PDF

The singulation study of $\mu$-BGA(Ball Grid Array) board using a pulsed Nd:YAG laser (펄스 Nd:YAG 레이저를 이용한 $\mu$-BGA 기판의 개별칩 분리 연구)

  • Baek, Kwang-Yeol;Lee, Kyoung-Cheol;Lee, Choen
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.524-527
    • /
    • 2000
  • In this paper, we have studied minimization of the burr which occurred after $\mu$-BGA(ball grid array) singulation process, singulation of the multilayer with a pulsed Nd:YAG(266, 532 nm) laser is used to cut the metal layer which doesn't well absorb laser beam. Especially, the photoresist and $N_2$blowing is effective to minimize of the surface demage and burr. In this experiment, the $N_2$ blowing reduces a laser energy loss by debris and suppress a surface oxidation. The SEM(scanning electron microscopes) and non-contact 3D inspector are used to measure cutting line-width and surface demage. The $\mu$-BGA singulation threshold energy is 75.0 J/cm$^2$at 30 ${\mu}{\textrm}{m}$/s scan speed.

  • PDF

A study on the Second-Harmonic Generation(SBG) Conversion Characteristics of Nd:YAG Laser adopted Differential Superposition Mesh (중첩회로를 적용한 펄스형 Nd:YAG 레이저의 2차 SHG 변환효율에 관한 특성연구)

  • 김휘영;박두열
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.215-218
    • /
    • 2001
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate. This system is controlled by microprocessor and allows to frequence an expensive condenser for high frequency to cheap one for low frequency. In addtion, The microcontroller monitors the flow of cooling water, short circuit, and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

The Weldability of Aluminum Ball in Electrolyte Injection Hole by Nd:YAG Laser (리튬이온전지의 전해액 주입구 볼에 대한 Nd:YAG 레이저 용접성)

  • Kim, Jong-Do;Yoo, Seung-Jo;Kim, Jang-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.740-745
    • /
    • 2006
  • This study suggested the occurrence source of weld-defects and its solution methods in a welding of Electrolyte injection hole by pulsed Nd:YAG laser. In experiment, the ramp down was used in order that solidification crack was removed. Furthermore. shrinkage stress and heat input were reduced by changing of weld trajectory and defocused distance. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained. In conclusion this show that the welding stability is greatly affected by modulation of laser pulse shape for the same laser energy and welding parameters.

The output characteristics of pulsed Nd:YAG laser with voltage variable capacitor-charging system (충전전압 가변방식을 이용한 펄스형 Nd:YAG 레이저의 출력특성에 관한 연구)

  • Moon, D.S.;Hong, J.H.;Song, K.Y.;Song, W.J.;Kim, K.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1703-1705
    • /
    • 2001
  • The pulsed Nd:YAG laser is used widely for materials processing and medical instrument etc. It is important to control the laser energy in those fields using a pulsed Nd:YAG laser. In this paper, constant-frequency current resonant half-bridge inverter and Cockcroft-Walton circuit are used to charge the energy storage capacitor variably. This laser power supply is designed and fabricated which has no high-voltage transformer, less switching losses, compact size and capability in varying the laser output power. Also, the output characteristics of this Nd:YAG laser system are investigated. The tested results are described.

  • PDF