• 제목/요약/키워드: Natural ventilation system

검색결과 195건 처리시간 0.037초

차량터널 오염물질 농도 예측 시뮬레이션 모델 연구 (Simulation Modelling of the Pollutant Concentration in Vehicle Tunnels)

  • 이창우;양원철;이송희
    • 터널과지하공간
    • /
    • 제6권1호
    • /
    • pp.57-63
    • /
    • 1996
  • The goal of this study is to develop a simulation model of the pollutant dispersion in vehicle tunnels, which can be utilized to optimize the tunnel ventilation system. Contaminant dispersion is modelled using a FDM solution of advective diffusion equation. Taking into consideration the local vehicle emission rates by year, it is user-oriented and its logic is generalized. Therefore, differences in the ventilation scheme can be easily adapted. The results of its application to a urban tunnel show that the relative errors are 1.1~6.8% for the natural velocity, 1.3% for the traffic-induced velocity and 2.9% for the total air quantity. Simulated CO concentrations along the entire tunnel show about 13% of the relative error.

  • PDF

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

공동주택 열교환기의 성능 및 에너지소비 특성 평가 (Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments)

  • 김상민;박병윤;손장열
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

멀티죤 시뮬레이션에 의한 공동주택의 미생물 오염원제거 성능평가에 관한 연구 (The study on the Performance of air sterilization of multistoried apartment by the multizone modeling)

  • 최상곤;박경수;윤영수;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.319-324
    • /
    • 2006
  • The purpose of this study Is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for Immune building systems.

  • PDF

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.

기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구 (A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan)

  • 김영식;정한식;정효민;최순호
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.191-200
    • /
    • 2016
  • 환기는 자연환기와 강제환기로 분류되며, 최근에는 하절기에 작업장의 환경개선을 위해 냉각된 공기를 공급하는 환기를 적용하는 경우가 많아지고 있다. 하지만 대규모의 작업장에 냉각된 공기를 공급하기 위해서는 많은 에너지가 필요하며, 이를 보완하기 위해 물의 증발열을 이용하여 공기를 냉각시킨 후 공급하는 환기장치의 도입사례가 증가하고 있으며, 본 실험연구는 부산의 모 신발공장에 실제 적용된 기화방열식 환기장치의 성능을 평가한 사례연구로서 하절기에 외부의 대기온도에 대해 어느 정도의 냉각능력을 구현할 수 있는지 측정하였다. 실험결과로부터 하절기에 약 $6{\sim}7^{\circ}C$ 정도의 냉각효과를 구현하지만 급기의 상대습도가 매우 높아짐을 정량적으로 측정할 수 있었다. 실험결과에 의하면 기화방열식 전체환기 설비가 타방식과 비교하여 작동방식이 단순하며, 에너지 소비가 적은 경제적인 냉각설비이며, 급기의 습도 제어기능만 부가되면 매우 효율적인 환기 - 냉각기능을 동시에 수행할 수 있는 설비임을 확인하였다.