과냉각을 동반한 동결과정의 수치해석 (Numerical Analysis for Cooling and Freezing Processes with Subcooling)

  • 윤정인;김재돌;김성규
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.451-462
    • /
    • 1996
  • In this study, which focuses on ice storage, a fundamental study in cooling and solidification was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation considering existence of subcooling and dendritic ice were analyzed numerically by using finite difference method and boundary fixing method. In the mesh, the solid fraction was introduced with adding as a term to the energy conservation equation. A flow in the dendrite was modelled as a flow in a porous medium, and the momentum conservation equation was modified to incorporate resistance forces involved in flows through porous media. A numerical solution of the time dependencies of dendrite area and dense ice front was successfully obtained, and the numerical results were good agreement with experimental results. Based on this methodology, a discussion was made of phenomena and characteristics of cooling and freezing processes under various conditions.

  • PDF

상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각 (Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity)

  • 유갑종;추홍록;김병하;최병철
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

PCM을 적용한 자연대류형 수냉식 방열기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of the Liquid Cooling Radiator of the Natural Convection Type by Using the PCM)

  • 성대훈;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.324-329
    • /
    • 2008
  • The liquid cooling effect of a natural convection type radiator by using the PCM has been investigated experimentally. The radiator size is $423{\times}295{\times}83$ mm and PCM container size is $398{\times}270{\times}26$ mm. The objective is elapsed time higher than maximum time to reach for maximum operating temperature of a general liquid cooling radiator. This study, in order to study on the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, ambient and melting point of three type PCM. For the above experimental parameter, the melting time was performed about 180/250/560 min at input power 150 W and ambient $30^{\circ}C$ from using the three type PCM(PCM_S1/S2/S3) respectively. Furthermore, the effects of the thermal dissipation was decreased higher input power than lower input power at heating block and melting time of PCM. However, the effects of mass flow rate did not nearly affect of the thermal performance especially.

  • PDF

Numerical simulation of natural convection around the dome in the passive containment air-cooling system

  • Chunhui Dong;Shikang Chen;Ronghua Chen;Wenxi Tian;Suizheng Qiu;G.H. Su
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2997-3009
    • /
    • 2023
  • The Passive containment Air-cooling System (PAS) can effectively remove the decay heat of the modular small nuclear reactor after an accident. The details of natural convection around the dome, which is a key part of PAS, were investigated numerically in the present study. The thermal dynamics around the dome were studied through the temperature, pressure and velocity contours and the streamlines. Additionally, the formation of the buoyant plume at the top of the dome was investigated. The results show that with the increase of Ra, the lift-off point moves toward the bottom of the dome, and the eddy under the buoyant plume grows larger gradually, which enhances the heat transfer. And the heat transfer along the dome surface with different truncation angles was investigated. As the angle increases, the heat transfer coefficient becomes stronger as well. Consequently, a newly developed heat transfer correlation considering the influence of truncation angle for the dome is proposed based on the simulated results. This study could provide a better understanding of natural convection around the dome of PAS and the proposed correlation could also offer more predictive value in the improvement of nuclear safety.

고출력 LED 램프 용 방사형 히트싱크의 형상 및 표면코팅이 LED 냉각성능에 미치는 영향에 대한 연구 (THE EFFECTS OF RADIAL HEAT SINK GEOMETRY AND SURFACE COATINGS ON THE LED COOLING PERFORMANCE FOR HIGH POWER LED LAMP)

  • 김효성;박상희;김동주;김경진
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2013
  • The purpose of this study is to investigate the cooling performance of radial heat sink used for high power LED lightings by natural convection cooling with surrounding air. Experimental and numerical analyses are carried out together. Parametric studies are performed to compare the effects of geometric parameters in radial heat sink such as the number of fins, fin height, fin length, and thickness of fin base as well as the surface coatings of radial heat sink. In this study, the cooling of 60 W LED lamp is examined with radiative heat transfer considered as well as natural convection. Numerical results show the optimum condition when the number of fin is 40, heat sink height is 120 mm, fin length is 15 mm, and fin base thickness is 3 mm. The difference in temperature of the LED metal PCB is within $1^{\circ}C$ between numerical analyses and experimental results. Also, the CNT coating on the heat sink surface is found to increase the cooling performance significantly.

변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구 (Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer)

  • 김국겸;서용권;강상모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.449-455
    • /
    • 2015
  • 전력용 변압기 용량의 증대와 고효율화에 따른 권선의 단위체적당 열발생량의 증가 및 이에 따른 절연성능의 저하는 전력용 변압기의 수명과 신뢰성에 큰 영향을 준다. 이러한 문제점은 방열기의 냉각성능을 증가시킴으로써 해결이 가능하다. 본 연구는 ONAF(Oil Natural Air Forced) 형식의 변압기의 방열기에 대해 공기의 강제대류를 일으키는 팬의 위치에 따른 냉각성능 평가를 통하여 냉각효과가 가장 큰 팬의 위치를 찾기 위한 것이다. 해석에는 유동해석 상용소프트웨어를 사용하였으며, 해석시간의 단축을 위하여 오일의 냉각유로를 단순화시켰고 팬의 지름을 일정하게 두고 팬의 위치를 다양하게 변화시켜가며 해석을 실행하였다. 해석 결과 팬의 수직적인 위치 변화는 냉각성능에 크게 영향을 주지 않았으나 팬이 변압기의 전방영역에 위치할 경우 후방영역의 배치보다 온도강하가 큰 것을 확인할 수 있었다.

유한 요소법을 이용한 히트싱크의 성능평가를 위한 열해석 연구 (Thermal Analysis of the Heat Sink Performance using FEM)

  • 이봉구;이민
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5467-5473
    • /
    • 2014
  • 최근 전자 및 기계부품 기술의 발전으로 전자 장비는 더욱 고성능화, 소형화, 다기능화 되면서 시스템 내부에 발생하는 발열부의 온도를 제어하기 위해 히트싱크가 사용된다. 본 연구에서는 내부 터널 구조의 2가지 형상의 히트싱크의 열 성능평가를 유한요소 프로그램인 ANSYS를 이용하여 수치해석 하였다. 수치해석은 자연대류 상태에서의 열 성능을 수치해석으로 비교 분석하여 냉각핀 형상에 따른 열 성능을 평가하였다. 또한 시간에 따른 열전달 특성과 온도분표의 해석결과를 기초로 하여 히트싱크의 성능평가를 예측하였다. 수치해석의 결과, 형상 A 히트싱크가 형상 B의 히트싱크보다 열 전달율이 자연대류에서 약 70% 향상되었다.

급배기 위치에 따른 바닥급기 공조시스템의 냉방 열환경 (Thermal Comfort of the Floor Supply Air Conditioning System for Different Supply-return Locations during Cooling)

  • 김요셉;김영일;유호선
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.476-485
    • /
    • 2000
  • This study numerically investigates thermal comfort in a space cooled by the floor-supply air conditioning system, in which three different supply-return locations, one floor supply-ceiling return and two floor supply-floor returns, are treated. A complementary experiment is peformed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through the diffuser is developed for efficient simulations. The calculated results show that the ceiling return type is far better in thermal comfort than the floor return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor supply-floor return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present estimation.

  • PDF

PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구 (An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs)

  • 성대훈;김민준;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF