• Title/Summary/Keyword: Natural air conditioning

Search Result 344, Processing Time 0.027 seconds

A Case Study on the Acclimatization's Housing for Environmental Load Reduction (환경부하 저감을 위한 기후순응주거 사례연구)

  • Cho, Sung-Woo;Oh, Se-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

Study on Evaporation Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 증발 압력강하 특성에 관한 실험적 연구)

  • Lee Kwang-Bae;Lee Ho-Saeng;Kim Jae-Dol;Yoon Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.533-539
    • /
    • 2005
  • Experimental results are presented for heat transfer and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers. Two tubes with a tube diameter of 12.70mm and 9.52mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7mm and 9.52mm. The results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

Dynamic Behavior Analysis of Scroll Compressor (스크롤 압축기의 동적 거동 해석)

  • Chun, Seung-woo;Park, Sung-jun
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.2
    • /
    • pp.49-54
    • /
    • 2012
  • These conventional reciprocating compressor(reciprocating type compressor) or household refrigerators and car air conditioning rotary compressor, rotary compressor, has been used by a reciprocating piston torque variability and the deepening of the vibration problem, the suction valve and discharge valvein this study, as a result of the losses in the current use of the scroll compressor, scroll compressor with the features of low noise, high efficiency, small size, light weight, has increased. fixed Scroll(fixed scroll) scroll compressor with orbiting scroll (rotating scroll) vibration experiments were performed in order to identify the vibration characteristics of the structure of the Analysis was performed using the commercial finite element program(ANSYS) for the sake of comparison, the experimental results using a finite element model of research about the natural vibration characteristics due to a material change.

  • PDF

Study on Condensing Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 응축 압력강하에 관한 연구)

  • Kim, Jae-Dol;Choi, Jun-Hyuk;Jeong, Seok-Kwon;Yoon, Jung-In;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

Dynamic Analysis of HVAC Case for Passenger Car (승용차용 HVAC Case의 동특성 해석)

  • Yook, Ji-Yong;Cha, Yong-Kil;Lim, Jung-Su;Kim, Kwang-Il;Kang, Sung-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.1
    • /
    • pp.101-108
    • /
    • 2009
  • This paper presents dynamic analysis of HVAC(heating ventilation & air conditioning) heater case which consists of heater and evaporator unit for passenger car. To analyze the dynamic characteristics of HVAC heater case, finite element model which consists of shell elements is constructed for modal analysis and experimental modal analysis has been conducted. Finite element analysis results are compared with experimental results to evaluate of validity of finite element model. After identifying mode shape and natural frequency of HVAC heater case, local stiffness of HVAC case is evaluated through point mobility using finite element analysis and experiment.

Heat and Mass Transfer Enhancement of a pendant droplet on heated horizontal surface by acoustic resonance (가열된 평판위에 매달려 있는 액적의 음향공진에 의한 열 및 물질 전달 촉진에 관한 연구)

  • Moon, Jong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.335-340
    • /
    • 2005
  • Nonlinear and forced oscillations of supported viscous droplet were focused in the present study. The droplet has a free contact line with solid plate and inviscid fluid. Natural frequencies of a pendant droplet have been investigated experimentally by imposing the acoustic wave while the frequency is being increased at a fixed amplitude. The evaporation was observed at atmosphere pressure. The droplet was recorded throughout the entire evaporation process and transient variations of the volume was measured. The evaporation process of oscillating droplet with thermofoil has been also observed to investigate analyzing the resonance effect on the thermal characteristics of droplet. It is found that a pendant droplet shows the resonant behaviors at each mode similar to the theoretical analysis. During imposing the acoustic wave, the pendant droplet makes a rotating motion in its longitudinal axis which is a new shape oscillation mode. The evaporation rate of a pendant droplet at resonant frequency is significantly enhanced.

  • PDF

Development on the Assessment Model for Selection of New DSM Investment Programs using MAUT (다속성 효용이론을 이용한 신규 수요관리 투자사업 선정평가 모델 개발)

  • Park, Sang-Yong;Lee, Deok-Ki;Lee, Jeong-Tae;Lee, Sang-Seol
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.231-236
    • /
    • 2008
  • The purpose of this study is to develop assessment model for selection of new DSM investment programs. In this research, MAUT method which find assessment value by each attributes related to selecting new DSM investment programs using utility function and integrate with structural frame was used to develop assessment model. In order to validate the usefulness of the model, assessment model was applied for actual candidate group of new DSM investment programs in natural gas domain. By utilize this assessment model to select new DSM investment programs, it is expected to minimize risk of new program launching and to maximize efficiency of DSM investment programs.

  • PDF

Development on the Computerizing Assessment System Model for DSM Investment Programs (수요관리투자사업 평가용 전산화 모델개발)

  • Lee, Sang-Seol;Lee, Chan-Seob;Cho, Sung-Hwan;Park, Sang-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.249-255
    • /
    • 2008
  • This paper developed the computerizing assessment system modeling of the natural gas and district heating DSM programs. It constructed as each project in accordance with the business investment plans & assessment DB, related M&V data DB and cost-effectiveness analysis data DB. It is composed of total 58 tables which are 22 tables which are used in the plan and the assessment, 16 tables which are used in the cost-effectiveness analysis, 18 tables which are used in the M&V, table which is used in qualitative evaluation, as by each programs. This computer programs can contributed to DSM business investment system construction as implementing for algorithm development and an estimation by each programs.

  • PDF

A study on humidity control characteristics of inorganic paint (무기질 도료의 조습성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-ho;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1225-1230
    • /
    • 2008
  • Recently the building material have been developed with the concept of controlling the indoor environment as well as the concept of emitting contaminants less. So, a lot of products with humidity control characteristics put it on the market. However, objective evaluation to these products doesn't work out. Thus consumers cannot obtain accurate information to these products. Therefore, we selected inorganic paint in the functionality materials and evaluated its humidity control characteristic in this research. We divided by four stages and evaluated this inorganic paint. The 1st and 2nd third experiments were executed on a natural condition and the fourth experiment was executed with humidity had been raised by using the humidifier.

  • PDF

Effects of surface radiation on the insulation for mechanical system (표면복사특성이 단열성능에 미치는 영향)

  • Oh, Dong-Eun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan;Kang, Byung-Ha;Kim, Suk-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1006-1011
    • /
    • 2006
  • In this study, a rational procedures for estimation of insulation thickness for condensation control or personnel protection has been investigated. Both horizontal pipe and vertical wall configuration are included. Design parameters are pipe diameter or, height of the wall, thermal conductivity, emissivity, and operating temperatures. The results Indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient. Adequate revision of specifications or standards has been also suggested.

  • PDF