• Title/Summary/Keyword: Natural Oscillation

Search Result 161, Processing Time 0.038 seconds

An experimental study on instability and control of co-flow diffusion flames (동축류 확산화염의 불안정성과 제어에 관한 실험적 연구)

  • Lee, Hyeon-Ho;Hwang, Jun-Yeong;Jeong, Seok-Ho;Lee, Won-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.153-164
    • /
    • 1997
  • Flame oscillation phenomena in a co-flow diffusion flame was experimentally studied with periodic fuel supply using a solenoid valve. The degree of excitation was controlled by changing the volume flux of fuel passing through the valve. Flame oscillation frequencies were measured utilizing a photodiode, a spectrum analyzer, video and high speed movies. Laser planar visualization was employed to study the correlation between the flame oscillation and the toroidal vortices. Observed are three regimes of flame oscillation, where the oscillation frequencies are for the multiples of excitation, the excitation itself and the flame natural oscillation. Both periods of natural oscillation and of excitation induced oscillation exist over one cycle of the excitation in the frequency multiplied regime. It is considered as an effect of balancing the influence of buoyancy driven vortex with that of excitation induced vortex near the excitation rate of 0.2. Flame shapes are become monotonous as increasing the excitation frequency to the range of over two fold of the natural oscillation. The flame oscillation can be modulated to the frequency of either multiples of excitation or excitation itself under certain conditions. This implies that the flame oscillation could be modulated to avoid the resonance frequency of the combustor, and shows the possibility of active control of the flame oscillation.

A Study on Weld Pool Oscillation for Pool Geometry Measurement (완전용입 풀의 진동을 이용한 형상측정에 관한 연구)

  • 유중돈
    • Journal of Welding and Joining
    • /
    • v.11 no.2
    • /
    • pp.62-73
    • /
    • 1993
  • Weld pool oscillation for the full-penetration GTA welding process was investigated for its possible application to weld penetration control through theoretical modeling and experiment. Energy method was used to estimate the natural frequency of the molten pool having the physically-acceptable weld geometry and oscillation modes. An unique experimental system was built which had the data acquisiton and video capabilities so that the pool oscillation signals and molten pool surfaces could be monitored continuously. Pool oscillation was detected through arc voltage and arc light emission simultaneously. The signal from arc light emission showed good coherence with that from arc voltage, and arc light generated the higher quality signal. The molten pool was found to oscillate in different oscillation modes based on the travel speed and weld geometry. The natural frequency estimated from the theoretical model agreed reasonably well with the experimental results.

  • PDF

Eaperimental Study on the Control of Harbor Oscillation due to Water Wave (파랑에 의한 항내진동의 제어에 관한 실험적 연구)

  • Choi, han kuy;Lee, Seon Yong
    • Journal of Industrial Technology
    • /
    • v.14
    • /
    • pp.101-107
    • /
    • 1994
  • This study is to investigate harbor oscillation phenomenon according to combination of the wall structures by model experiment in a three dimensional wave basin. Six different types of wall combination were chosen through combination of erect wall, erect dissipation block, and sand beach, wave height at selected points in the harbor were measured by electronic wave gage. Test results show that the wall structure composed solely of erect walls showed generally highest harbor oscillation. Since natural beach shows lower reflection than erect dissipation block do, we thought it would be more efficient to use natural beach for improved harbor oscillation. The result showed, however, that the erect dissipation block are more efficient than natural beach to attain less harbor oscillation. The reason seens that the erect dissipation blocks have better capability to control breaking wave on the surface of the structure.

  • PDF

A Study on Dynamic Stiffness of Inspection Robot Frame Considering Sub-span Oscillation (서브스판 진동을 고려한 송전선로 검사로봇 프레임 구조 설계에 관한 연구)

  • Kim, Moon Young;Lee, Jun Young;Lee, Taikjin;Yim, Hong Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.827-829
    • /
    • 2014
  • This paper presents a design methodology for improving dynamic stiffness of an inspection robot frame to prevent resonance. Finite element models of robot frame are developed for natural frequency analysis. Natural frequency analysis of robot frame is conducted to compare with sub-span oscillation which is excitation frequency. Reinforcement beams are applied to the sensitive parts of the robot frame to improve dynamic stiffness using case study. To reduce mass of the robot frame, thickness optimization of the robot frame is carried out by utilizing response surface method. The result of optimization show that dynamic stiffness of robot frame is increased. As a result, natural frequency of an optimal model is not included in range of frequencies of the sub-span oscillation.

  • PDF

Natural vibration of the three-layered solid sphere with middle layer made of FGM: three-dimensional approach

  • Akbarov, Surkay D.;Guliyev, Hatam H.;Yahnioglu, Nazmiye
    • Structural Engineering and Mechanics
    • /
    • v.57 no.2
    • /
    • pp.239-263
    • /
    • 2016
  • The paper studies the natural oscillation of the three-layered solid sphere with a middle layer made of Functionally Graded Material (FGM). It is assumed that the materials of the core and outer layer of the sphere are homogeneous and isotropic elastic. The three-dimensional exact equations and relations of linear elastodynamics are employed for the investigations. The discrete-analytical method proposed by the first author in his earlier works is applied for solution of the corresponding eigenvalue problem. It is assumed that the modulus of elasticity, Poisson's ratio and density of the middle-layer material vary continuously through the inward radial direction according to power law distribution. Numerical results on the natural frequencies related to the torsional and spheroidal oscillation modes are presented and discussed. In particular, it is established that the increase of the modulus of elasticity (mass density) in the inward radial direction causes an increase (a decrease) in the values of the natural frequencies.

Updated Trends of Stratospheric Ozone over Seoul (서울 상공의 최신 성층권 오전 변화 경향)

  • Kim, Jhoon;Cho, Hi-Ku;Lee, Yun-Gon;Oh, Sung Nam;Baek, Seon-Kyun
    • Atmosphere
    • /
    • v.15 no.2
    • /
    • pp.101-118
    • /
    • 2005
  • Atmospheric ozone changes temporally and spatially according to both anthropogenic and natural causes. It is essential to quantify the natural contributions to total ozone variations for the estimation of trend caused by anthropogenic processes. The aims of this study are to understand the intrinsic natural variability of long-term total ozone changes and to estimate more reliable ozone trend caused by anthropogenic ozone-depleting materials. For doing that, long-term time series for Seoul of monthly total ozone which were measured from both ground-based Dobson Spectrophotometer (Beck #124)(1985-2004) and satellite TOMS (1979-1984) are analyzed for selected period, after dividing the whole period (1979~2004) into two periods; the former period (1979~1991) and the latter period (1992~2004). In this study, ozone trends for the time series are calculated using multiple regression models with explanatory natural oscillations for the Arctic Oscillation(AO), North Atlantic Oscillation(NAO), North Pacific Oscillation(NPO), Pacific Decadal Oscillation(PDO), Quasi Biennial Oscillation(QBO), Southern Oscillation(SO), and Solar Cycle(SC) including tropopause pressure(TROPP). Using the developed models, more reliable anthropogenic ozone trend is estimated than previous studies that considered only QBO and SC as natural oscillations (eg; WMO, 1999). The quasi-anthropogenic ozone trend in Seoul is estimated to -0.12 %/decade during the whole period, -2.39 %/decade during the former period, and +0.10 %/decade during the latter period, respectively. Consequently, the net forcing mechanism of the natural oscillations on the ozone variability might be noticeably different in two time intervals with positive forcing for the former period (1979-1991) and negative forcing for the latter period (1992-2004). These results are also found to be consistent with those analyzed from the data observed at ground stations (Sapporo, Tateno) of Japan. In addition, the recent trend analyses for Seoul show positive change-in-trend estimates of +0.75 %/decade since 1997 relative to negative trend of -1.49 %/decade existing prior to 1997, showing -0.74 %/decade for the recent 8-year period since 1997. Also, additional supporting evidence for a slowdown in ozone depletion in the upper stratosphere has been obtained by Newchurch et al.(2003).

Lock-on Characteristics of wake behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성)

  • Lee Jung Yeop;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.18-21
    • /
    • 2004
  • Lock-on characteristics of the flow around a circular cylinder performing a rotationally oscillation with a relatively high forcing frequency have been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), amplitude of oscillation $(\theta_A)$, and frequency ratio $F_R=f_f\;/\;f_n$, where $f_f$ is the forcing frequency and if is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14\times10^3,\;\pi/15\leq\theta_A\leq\pi/3$, and $F_R=1.0$. The effects of this active control technique on the lock-on flow regime of the cylinder wake were evaluated through wake velocity measurements and spectral analysis of hot-wire signals. The rotary oscillation modified the flow structure of near wake significantly. The lock-on phenomenon was found to occur in the range of frequency encompassing the natural vortex shedding frequency. In addition, when the amplitude of oscillation is less than a certain value, the lock-on phenomenon was occurred only at $F_R=1.0$. The lock-on range expanded and vortex formation length decreased as the amplitude of oscillation increases. The rotary oscillation generated small-scale vortex structure just near the cylinder surface.

  • PDF

The Oscillation Characteristics of a Magneticfluid Plug in Curved Tube (곡관내 자성유체 PLUG의 진동특성)

  • Chun, U.H.;Lee, H.N.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.46-57
    • /
    • 1995
  • The aim of the present study is to provide fundamental informations for the development of magneticfluid actuator. To achieve the aim, oscillation characteristics of the magneticfluid plug are investigated by experiment for the various length and position of the magneticfluid plug and the frequency of magnetic field. The oscillation characteristics are obtained. Amplitude, natural frequency, phase shift and damping ratio, are compared with theoretical values. From the study, the following conclusive remarks can be made. The experimental equation for the magnetic field is obtained. The critical magneticfluid length exists and its value is about 70mm. The range of the damping ratio and fluid loss coefficient obtained by experiment are 0.1~0.2 and 30~100, respectively. Comparison between experimental and theoretical results of oscillation characteristics shows good agreement in the high frequency range. Meanwhile, in the low frequency range, there appears little discrepancies(5% in the frequency and amplitude and 10% in phase difference and damping ratio) with each other.

  • PDF

A Frequency Analysis of Subspan Oscillation on Overhead Transmission Lines (가공송전선로의 서브스판 진동에 대한 주파수 특성 분석)

  • Sohn, Hong-Kwan;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.519-521
    • /
    • 2003
  • This paper presents a frequency analysis of subspan oscillation on overhead transmission line. The Oscillation frequency is a natural characteristic of a subspan and can be calculated. But it is not same to calculated frequency, because it has been composed several frequencies of adjacent subspan. We were analyzed to the frequency of subspan oscillation by FFT methods. This result will use to establish of the subspan location rules.

  • PDF

A cause analysis of Noise & Vibration of Gas Heater (가스히터의 소음 진동 원인 분석)

  • Koh, Jae-Pil;You, Hyun-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • A cause of noise and vibration which come from a Combustion of gas heater are a combustion roar and Combustion oscillation. A character of a combustion roar is that sound pressure is distribute with broad band frequency. otherwise, The presence of combustion oscillation caused by positive Feed Back in Combustion Chamber break out a noise and vibration. Accordingly, The method that be solved a noise and vibration is to make each natural frequency different frequency. first, in order to solve problem, we control ratio of fuel and air. that is, Keep away resonance. second, in order to changing natural frequency of Combustion Chamber, We changed the shape of Economizer.

  • PDF