• Title/Summary/Keyword: Natural Energy

Search Result 3,727, Processing Time 0.029 seconds

Kernel Fisher Discriminant Analysis for Natural Gait Cycle Based Gait Recognition

  • Huang, Jun;Wang, Xiuhui;Wang, Jun
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.957-966
    • /
    • 2019
  • This paper studies a novel approach to natural gait cycles based gait recognition via kernel Fisher discriminant analysis (KFDA), which can effectively calculate the features from gait sequences and accelerate the recognition process. The proposed approach firstly extracts the gait silhouettes through moving object detection and segmentation from each gait videos. Secondly, gait energy images (GEIs) are calculated for each gait videos, and used as gait features. Thirdly, KFDA method is used to refine the extracted gait features, and low-dimensional feature vectors for each gait videos can be got. The last is the nearest neighbor classifier is applied to classify. The proposed method is evaluated on the CASIA and USF gait databases, and the results show that our proposed algorithm can get better recognition effect than other existing algorithms.

A Study on the Efficiency Improvement of the Power Generation Process Using New Working Fluids Composed of Methane, Ethylene, Ethane, and Propane and the Cold Heat Contained in the Liquefied Natural Gas (메탄, 에틸렌, 에탄 및 프로판으로 구성된 새로운 작동 유체와 액화 천연가스의 냉열을 활용한 발전 공정의 효율 향상에 대한 연구)

  • JUNGHO CHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.3
    • /
    • pp.318-323
    • /
    • 2024
  • In this paper, computer modeling works have been performed for the power generation Rankine cycle using new working fluids and liquefied natural gas (LNG) cold heat. PRO/II with PROVISION released January 2023 from AVEVA company was used, and Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the power generation cycle. Optimal working fluid composition was determined to maximize LNG cold heat to increase power generation efficiency and net power production.

Phase Equilibrium Conditions of Gas Hydrates for Natural Gas Solid Transportation and Storage (천연가스 고체수송 및 저장을 위한 가스 하이드레이트 상평형 조건에 대한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Chong-Bo;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.266-273
    • /
    • 2008
  • Natural gas hydrates are ice-like solid substances, which are composed of water and natural gas, mainly methane. They have three kinds of crystal structures of five polyhedra formed by hydrogen-bonded water molecules, and are stable at high pressures and low temperatures. They contain large amounts of organic carbon and widely occur in deep oceans and permafrost regions. Therefore, they are expected as a potential energy resource in the future. Especially, $1m^3$ natural gas hydrate contains up to $172Nm^3$ of methane gas, de pending on the pressure and temperature of production. Such large volumes make natural gas hydrates can be used to store and transport natural gas. In this study, three-phase equilibrium conditions for forming natural gas hydrate were numerically obtained in pure water and single electrolyte solution containing 3 wt% NaCl. The results show that the predictions match the previous experimental values very well, and it was found that NaCl acts as an inhibitor. Also, help gases such that ethane, propane, i-butane, and n-butane reduce the hydrate formation pressure at the same temperature.

Analysis of dynamic behavior for truss cable structures

  • Zhang, Wen-Fu;Liu, Ying-Chun;Ji, Jing;Teng, Zhen-Chao
    • Steel and Composite Structures
    • /
    • v.16 no.2
    • /
    • pp.117-133
    • /
    • 2014
  • Natural vibration of truss cable structures is analyzed based upon the general structural analysis software ANSYS, energy variational method and Rayleigh method, the calculated results of three methods are compared, from which the characteristics of free-vibration are obtained. Moreover, vertical seismic response analysis of truss cable structures is carried out via time-history method. Introducing three natural earthquake waves calculated the results including time-history curve of vertical maximal displacement, time-history curve of maximal internal force. Variation curve of maximal displacement of node along span, and variation curve of maximal internal force of member along span are presented. The results show the formulas of frequencies for truss cable structures obtained by energy variational method are of high accuracy. Furthermore, the maximal displacement and the maximal internal force occur near the 1/5 span point. These provide convenient and simple design method for practical engineering.

Finite element analysis of reactor internals with structural faults (기계적 결함이 있는 원자로 내부구조물의 유한요소해석)

  • Jung, Seung-Ho;Park, Jin-Seok;Kim, Tae-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.8
    • /
    • pp.1270-1275
    • /
    • 1997
  • This paper concerns with the finite element analysis of reactor internals with structural faults. For investigating the influence of hold-down spring faults on dynamic characteristics of CSB (core support barrel), reactor internals of Ulchin-1 nuclear power plant are modeled using finite element method and simulated with artificial defects on the hold-down springs. To prove the validity of the finite element models, the calculated natural frequencies of CSB in normal state are compared with those from the measurement results, which shows good agreement. According to results of finite element analysis, CSB beam mode natural frequency decreases by 4.5% in the case of 10% partial relaxation of hold-down springs, and decreases by 18.4% in the case of 20%. The range of shell mode natural frequency change is within 5.3%.

Experimental Study on Inward Melting of Phase Change Material in Inclined Circular Tube (경사진 원통형 용기내에서 상변화 물질의 내향 용융에 관한 실험적 연구)

  • Yim, Chang-Soon;Son, Ha-Jin
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.48-58
    • /
    • 1992
  • In the present investigation, experimental analysis was performed to research heat transfer phenomena generated by means of conduction and natural convection at a succession of tube-inclimations relative to the vertical tube during inward melting process of a phase change material. The phase change material used in the experiments is 99 percent pure n-docosane paraffin($C_{22}H_{46}$). When the tube is vertical, the dominant mode of energy transfer between the tube wall and the melting interface is natural convection. On the other hand, when the tube is inclined to the vertical, the melting solid is brought into direct contact with the tube wall by the action of gravity. In the experimental results, direct contact gave rise to substantial enhancements in the amount of melted mass, relative to those for natural-convection-dominated melting.

  • PDF

Status of Gas Hydrate Technology Development (가스하이드레이트 기술개발현황)

  • Ahn, Young-Hun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.686-686
    • /
    • 2009
  • 가스하이드레이트는 수소결합을 하는 물분자의 고체상 격자(Lattice)내에 포집되어 들어가는 기체분자로 구성된 결정화합물로서 외형적인 형태는 얼음과 거의 유사하다. 천연가스 하이드레이트 기술의 최대장점으로는 액화천연가스(LNG)는 초저온인 $-162^{\circ}C$의 저장조건이 필요하지만 천연가스하이드레이트(NGH)기술은 비교적 온화한 조건인 $-15^{\circ}C$에서 천연가스를 고체상태로 저장/이용할 수 있다는 것이다. 천연가스를 $-162^{\circ}C$에서 액화시킨 LNG상태로 생산, 수송, 저장하는 경우보다 고체상태인 NGH(Natural Gas Hydrate)로 만들어서 생산, 수송, 저장할 경우 천연가스의 생산, 수송, 저장, 재가스화 등의 일련의 공정과 비교해볼 때 LNG방법보다 약 24%이상의 경비를 절감을 할 수 있다고 보고되어지고 있다. 따라서, 천연가스의 수송 및 저장기술에서의 탁월한 경제성으로 인해 선진국에서는 가스하이드레이트에 대한 활발한 연구가 진행되고 있다. 특히 일본은 5Ton/Day용량의 NGH 생산플랜트를 건설하여 시운전 중에 있다. NGH기술의 주요 활용분야는 대용량의 가스매장량을 요구하여 LNG공정기술을 적용할 수 없는 중소형가스전 또는 한계가스전에 경제적으로 적용하는 해양수송분야와 천연가스 공급망이 갖춰져 있지 못한 지역에 NGH Pellet형태로 수송/재기화하여 활용하는 내륙운송이 분야가 있다. 국내에서는 지식경제부 국책과제인 ETI(Energy Technology Innovation)사업을 시작으로 국가경쟁력 제고 차원에서 이러한 기술의 기반구촉 및 실증화 사업이 진행되고 있다. 주요 내용으로는 NGH Process Flow, Overall NGH Process concept diagram, NGH Carrier outline, NGH Land Transportation chain 등이 포함되어 있다.

  • PDF

Natural Convection Heat Transfer in a Hemispherical Pool with Volumetric Heat Sources (체적 열원이 내재된 반구에서의 자연대류 열전달)

  • Park, Hae-Kyun;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.135-141
    • /
    • 2015
  • The core melts stratifies into lower mixture layer and upper metal layer by density in a severe accident condition. The decay heat generated from the mixture layer threatens the integrity of the reactor vessel. This study simulated the natural convection heat transfer of the mixture layer with volumetric heat source using the mass transfer system. $H_2SO_4-CuSO_4$ electroplating system was used as the mass transfer system. With the modified Rayleigh number of $3{\times}10^{14}$, the Nusselt number showed minimum at the bottom and increased along curvature to the top of the experimental apparatus.

Combustion Characteristics of HCNG Burner System with Tail Gas Addition (HCNG용 버너시스템에서 Tail Gas 첨가 시 연소특성)

  • Han, J.O.;Lee, J.S.;Kim, H.T.;Kim, S.M.;Lee, Y.C.;Kim, Y.C.;Hong, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.2
    • /
    • pp.36-39
    • /
    • 2015
  • The combustion characteristics of metal fiber burner fueled natural gas with tail gas produced from reforming process were analyzed on the point of flame stability and excess air conditions. Also, it was analyzed the effect of energy efficiency improvement due to decrease the fuel input in reforming system by using residue gases. As a results, it was confirmed that tail gas including hydrogen, CO and $CO_2$ could be directly injected without any change of air control system in natural gas burner and also energy efficiency was increased up to 30% maintained stable combustion.

Survey evaluation of thermal boundary condition in the inside and outside of double skin facade

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.29-35
    • /
    • 2015
  • Purpose: Double skin facade is a representative advantageous passive technology of building skin in the aspect of energy saving and environment improvement, reduces heat loss with buffer space in winter season and enhances indoor air and comfort of residents by activating natural ventilation in mid-season. However, in summer season, temperature increase in the intermediate space due to solar energy from exterior transparent skin could be a potential problem; also, relatively weak buoyancy of air caused by low density difference between double-skin facade could increase cooling load as air of intermediate space in high temperature hangs. However, proof data is insufficient to objectify such phenomenon. Method: In this study, researchers surveyed air temperature of intermediate space and airflow and diagnosed its cause targeting on applied multistory facade in the building which gives thermal uncomfort to residents. Also, the researchers produced Solar-air heat transfer coefficient meter, measured thermal boundary condition of double-skin facade, and presented the result of measurement as an objectified verification material regarding overheating phenomenon in the intermediate space of double-skin facade in summer season. Result: Inefficient condition was verified that total heat increases and overheating due to insufficient natural ventilation in multistory facade. In addition, logic behind preceding research was objectified and verified regarding high temperature phenomenon in the intermediate space which could increase cooling load in summer season.