• Title/Summary/Keyword: National comparison

Search Result 14,690, Processing Time 0.047 seconds

A Comparison of the Characteristics by SRM Drives Using Search Coils (서치코일을 이용한 SRM의 구동법 비교)

  • Yang H. Y.;Shin D. S.;Lim Y. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.926-930
    • /
    • 2004
  • This paper presents a comparison of the characteristics by two types of switched reluctance motor (SRM) drives using search coils, Exterior pole search coil and Interior central pole search coil, which are used for estimation of the rotor position. The advantages and disadvantages of the two types of drive methods are also described.

  • PDF

Carrier Comparison PWM for Voltage Control of Vienna Rectifier (비엔나 정류기의 전압제어를 위한 반송파 비교 PWM)

  • Yoon, Byung-Chul;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4561-4568
    • /
    • 2011
  • In this paper, carrier comparison PWM method for voltage control of Vienna rectifier is discussed. In general, in industrial and communications applications, the two-level rectifier is used. However, this two-level rectifier has the limit of high THD and low efficiency. So, the studies of three-level rectifier has been carried out so far, and the Vienna rectifier circuit is the representative. The space vector pulse width modulation(SVPWM) method is generally used for Vienna rectifier, in which voltage vectors and duration time are calculated from the voltage reference. However, this method require very sophisticated and complex calculations, so realizing this method by software is very difficult. To overcome this disadvantage, simple carrier comparison PWM method for Vienna rectifier is proposed which is modified from the carrier comparison method for 3 level inverter. Furthermore, to verify the usefulness of the Vienna rectifier carrier comparison PWM the simulation and experiment are carried out.

A Performance Analysis of Phase Comparison Monopulse Algorithm for Antenna Spacing and Antenna Array (안테나 간격 및 배열에 따른 위상 비교 모노펄스 알고리즘의 성능 분석)

  • Sim, Heon-Kyo;Jung, Min-A;Kim, Seong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1413-1419
    • /
    • 2015
  • Monopulse RADAR is the radar which detects the range of the target using a single transmitted signal. In this paper, using 9.41GHz X-band radar, the research for the phase comparison monopulse algorithm used in the marine environment is conducted. In addition, by applying the phase comparison monopulse algorithm, we calculate the RMSE for the various antenna spacings and the positions of the target. Based on that result, we compare the performance of the phase comparison monopulse algorithm in the uniform linear array with that in the non-uniform linear array. Finally, the differences in performance among the MUSIC algorithm, Bartlett method and the proposed phase comparison monopulse algorithm are analyzed.

Comparison of two types of Permanent Magnet Linear Synchronous Motor with the Minimum Detent Force

  • Jang, Seok-Myeong;Lee, Sung-Ho;Yoon, In-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.146-150
    • /
    • 2001
  • Comparison on the performances between the Halbach array type permanent magnet linear synchronous motor (HA-PMLSM) and the convensional array type permanent magnet linear synchronous motor (CA-PMLSM) was made with finite element analysis (FEA) and experiment. The HA-PMLSM is seen to be superior to the CA-PMLSM. Optimum ratio of magnet length to slot pitch of the HA-PMLSM which reduces the detent force was determined. Also, Comparison of forces of the HA-PMLSM and the CA-PMLSM with minimum detent force is presented.

  • PDF

Comparison and Analysis for Open-circuit Field of PM Machines with Halbach and Circumferential Magnetized Rotor (Halbach자화 및 원주방향 자화된 회전자를 갖는 영구자석 기기의 무부하시 자계분포 특성해석 및 비교)

  • Jang, Seok-Myeong;Choi, Jang-Young;Cho, Han-Wook;Yang, Hyun-Sup;Lee, Sung-Ho;Jeong, Sang-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.86-88
    • /
    • 2004
  • This paper deals with the comparison and analysis for open-circuit field of PM(permanent magnet) machines with Halbach and circumferential magnetized rotor. The governing equation is derived in terms of magnetic vector potential and 2-d polar coordinate. And then, analytical results has been verified by comparison with those obtained from FE(finite element) method. On the basis of 2-d analytical results, this paper confirms that PM machines with circumferential magnetized rotor is superior to it with Halbach magnetized rotor in terms of magnitude and sinusoidal wave-forms of flux density due to PM and required magnet volume.

  • PDF

Comprehensive comparison of normality tests: Empirical study using many different types of data

  • Lee, Chanmi;Park, Suhwi;Jeong, Jaesik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.5
    • /
    • pp.1399-1412
    • /
    • 2016
  • We compare many normality tests consisting of different sources of information extracted from the given data: Anderson-Darling test, Kolmogorov-Smirnov test, Cramervon Mises test, Shapiro-Wilk test, Shaprio-Francia test, Lilliefors, Jarque-Bera test, D'Agostino' D, Doornik-Hansen test, Energy test and Martinzez-Iglewicz test. For the purpose of comparison, those tests are applied to the various types of data generated from skewed distribution, unsymmetric distribution, and distribution with different length of support. We then summarize comparison results in terms of two things: type I error control and power. The selection of the best test depends on the shape of the distribution of the data, implying that there is no test which is the most powerful for all distributions.

Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbines

  • Lee, Kihyun;Jung, Kyungsub;Suh, Yongsug;Kim, Changwoo;Cha, Taemin;Yoo, Hyoyol;Park, Sunsoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.386-387
    • /
    • 2013
  • This paper provides a comparison of high power semiconductor devices in 5MW-class Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) wind turbines. High power semiconductor devices of IGBT module type, IGBT press-pack type, and IGCT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on neutral-point clamed 3-level back-to-back type voltage source converter supplied from grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through the loss analysis considering both conduction and switching losses under the given operating conditions of 5MW-class PMSG wind turbines, particularly for the application in offshore wind farms. The loss analysis is confirmed through PLECS simulations. The comparison result shows that IGBT press-pack type semiconductor device has the highest efficiency and IGCT has the lowest cost factor considering the necessary auxiliary components.

  • PDF

The effects of academic stress, social network service addiction tendency, and upward social comparison on depression in nursing students (간호대학생의 학업스트레스, 소셜네트워크서비스 중독경향, 상향비교성향이 우울에 미치는 영향)

  • Park, Seungmi;Lee, Jung Lim;Yu, Soo-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.29 no.1
    • /
    • pp.41-50
    • /
    • 2023
  • Purpose: The aim of this descriptive study was to identify the factors influencing depression risk among South Korean nursing students. Methods: The data were collected from nursing students attending two universities through web-based questionnaires that surveyed them about depression, academic stress, social network service (SNS) addiction tendency, and upward social comparison from August 22 to September 4, 2021. The collected data from 196 nursing students were analyzed by t-test, one-way ANOVA, Pearson's correlation coefficients, and multiple linear regression. Results: The mean score of depression (using CES-D Korean version) among nursing students was 13.91, which denotes probable depression. Concerning the variance with regard to depression among nursing students, 20.2% was explained by clinical practice period, academic stress, and upward social comparison. Conclusion: Programs to relieve academic stress and depression should be developed in a simple way and systematically provided at the organizational level so that nursing students secure sufficient support during the initial and continuing period of clinical practicums. Concomitantly, an attempt to reduce the upward social comparison should be highly considered.