• 제목/요약/키워드: National Forensic Service

검색결과 189건 처리시간 0.022초

엘러스-단로스 제4형 증후군 환자에서 발생한 대동맥 파열 ([Secondary publication] Sudden Aortic Rupture in Ehlers-Danlos Syndrome Type IV)

  • 백태화;김민정;기창석;박성환;이헌;김경열;최병하
    • The Korean Journal of Legal Medicine
    • /
    • 제40권2호
    • /
    • pp.61-64
    • /
    • 2016
  • Ehlers-Danlos syndrome type IV (EDS IV) is a hereditary disorder of the connective tissue, characterized by easy bruising, thin skin with visible veins, and spontaneous rupture of the large arteries, uterus, or bowel. EDS IV is caused by mutations of the gene for type III procollagen (COL3A1), resulting in insufficient collagen production or a defect in the structure of collagen. EDS IV can have fatal complications such as the rupture of great vessels or organs, which can cause hemorrhaging and sudden unexpected death. Here, we report a case of a 43-year-old female who collapsed after a struggle with a neighbor. In this patient, the bifurcation of the bilateral common iliac artery ruptured, with no evidence of trauma, inflammation, or atherosclerosis. Genetic analysis of COL3A1 showed the presence of a c.2771G>A (p.Gly924Arg) mutation, which may be associated with EDS IV. The forensic pathologist should consider the possibility that the spontaneous visceral or arterial rupture was caused by EDS IV. Genetic analysis is not currently a routine procedure during autopsy. However, in this case, we suggest that the patient possibly had an underlying EDS IV condition, and we recommended family members of the deceased to seek genetic analysis and counseling.

전기장판 열선 결함에 의한 전기화재 원인분석 (Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires)

  • 송재용;사승훈;남정우;김진표;조영진;오부열
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

바이메탈식 온도센서를 적용한 건조설비에서의 화재 위험성 연구 (Study of the Fire Risk Caused by the Use of a Bimetal type Thermometer in the Drying Equipment)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.73-78
    • /
    • 2017
  • 본 논문에서는 바이메탈식 온도센서를 적용한 건조설비에서의 화재 위험성에 대하여 연구하였다. 건조설비는 산업현장 등에서 광범위하게 사용되고 있으며, 건조 대상물이 가열될 때 발생하는 가연성 가스 및 증기에 의한 폭발 및 화재 등이 일어나기 용이하기 때문에 구조와 사용방법 등에 대한 규제가 엄격하게 이루어지고 있지만 부적합한 온도센서를 활용한 건조로 등의 내부온도 측정시 정확한 온도 측정이 이루어지지 못하는 경우에는 그만큼 화재 위험성이 증가하게 된다. 따라서 본 논문에서는 건조설비에 광범위하게 사용되고 있는 바이메탈식 온도센서의 구조를 분석하고, 측정 대상물의 성상에 따른 온도 측정 실험을 수행하였다. 측정 대상물에 따른 온도 측정 결과, 기체 및 고체에 대한 온도 측정에 있어서는 실제 온도에 비해 낮은 온도로 측정되었으며, 액체 대상물의 경우에는 비교적 정확한 온도 측정이 가능하였다. 이러한 실험 결과로부터 바이메탈식 온도센서는 기체 및 고체의 온도 측정에는 부적합하며, 액체의 온도 측정에 보다 적합한 특성을 나타내었다.

차량크레인 전도 사고의 구조 안정성 평가에 관한 법공학적 연구 (Forensic Engineering Study on the Evaluation of the Structural Stability of the Mobile Crane Accident)

  • 김종혁;김의수
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.11-17
    • /
    • 2013
  • Forensic Engineering is the area covering the investigation of products, structures that fail to perform or do not function as intended, causing personal injury or damage to property. To investigate the mobile crane's overturn accident in terms of the forensic engineering, in this study, we identified the accident mobile crane's position and posture before accident by the analysis of the trace resulted by the contact between the outrigger and the ground, and the accident remodeling has been performed using CATIA modeling program in the basis of the accident mobile crane's position and posture information. The accident analysis has been performed by comparing this accident remodeling and the crane's specification, the table of the allowance load about the boom's length and the working radius. Through these studies, the safety accident that may occur in mobile crane can be minimized by performing specialized and systematic investigation of the accident cause in terms of the forensic engineering.

스테인레스강 SS420의 입계예민화에 의한 피트 부식 (Pit Corrosion of SS420 Stainless Steel by Grain Boundary Sensitization)

  • 최병학;이범규;장현수;박찬성;김진표;박남규;김청인;김보미
    • 한국재료학회지
    • /
    • 제27권8호
    • /
    • pp.431-437
    • /
    • 2017
  • This study investigated the surface pit corrosion of SS420J2 stainless steel accompanied by intergranular crack. To reveal the causes of surface pits and cracks, OM, SEM, and TEM analyses of the microstructures of the utilized SS420J2 were performed, as was simulated heat treatment. The intergranular cracks were found to have been induced by a grain boundary carbide of $(Cr,Fe)_{23}C_6$, which was identified by SEM/EDS and TEM diffraction analyses. The mechanism of grain boundary sensitization occurred at the position of the carbide, followed by its occurrence at the Cr depleted zone. The grain boundary carbide of $(Cr,Fe)_{23}C_6$ type precipitated during air cooling condition after a $1038^{\circ}C$ solid solution treatment. The carbide precipitate formation also accelerated at the band structure formed by cold working. Therefore, using manufacturing processes of cooling and cold working, it is difficult to protect SS420J2 stainless steel against surface pit corrosion. Several counter plans to fight pit corrosion by sensitization were suggested, involving alloying and manufacturing processes.

SPE 및 GC/MS에 의한 혈액중 스트리크닌의 분석법 개발 및 검출사례 (Method Development and Validation of Strychnine in Blood by Gas Chromatography/Mass Spectrometry Using Solid Phase Extraction and its Application in Real Specimens)

  • 이종숙;염혜선;문성민;이상기
    • 약학회지
    • /
    • 제57권2호
    • /
    • pp.87-94
    • /
    • 2013
  • An analytical methodology based on solid-space extraction (SPE) with with Bond Elut Certify cartridge (Varian, 130 mg) has been developed for the qualification and quantitation of strychnine in blood. After the elution layer was evaporated, the residue was reconstituted with methanol for GC/MS. Internal standard was used 10 mg/l dextromethorphan. Strychnine is a potent central nervous stimulant and convulsant, and an alkaloid found in seeds of Strychnos nux-vomica. It was used therapeutically to improve circulation and muscle tone in oral or intramuscular doses of 0.05~8 mg. The fatal dose of strychnine for humans is 50~100 mg. A man was found dead lying curled up the corner of the large room in a roof house after the fire fighter opened a locked door inside to put out the fire. The postmortem blood and gastric contents were analyzed for toxicological testing. Strychnine and brucine were detected using GC/MS first in gastric contents extracts. The contents of strychnine was 0.083 mg/l in heart blood, 0.088 mg/l in peripheral blood and 4.0 mg/kg in gastric contents, respectively. Method validation was carried out in terms of linearity, accuracy, precision (intraday, interday) in blood. The assay is linear over 0.05~10 mg/l ($r^2$=0.999). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.02 mg/l (S/N=3) and 0.07 mg/l (S/N=10), respectively. Accuracy (bias%) of strychnine with 0.1, 1 and 10 mg/l was 12.0% (n=6), 9.3% (n=6) and 6.9% (n=6), respectively. Intraday precision (CV%) of strychnine with, 0.1, 1 and 10 mg/l were 6.4%, 10.4%, 1.2% (n=6), respectively. Interday precision (CV%) of strychnine with 0.1, 1 and 10 mg/l over three days were 24.0%, 18.5%, 13.8% (n=18), respectively. Relative recovery with 0.1, 1 and 10 mg/l (in blood) were 114.9%, 99.3% and 87.4% (n=6), respectively. The described method can be applied in forensic toxicology to determine strychnine in blood samples.

미지시료에서 부신피질호르몬제의 확인을 위한 라이브러리 구축 (Establishment of Library for the Identification of Corticosteroids in Various Known Sample Types)

  • 박미정;홍효정;이상기
    • 약학회지
    • /
    • 제55권4호
    • /
    • pp.289-294
    • /
    • 2011
  • Illegal addition of steroids into cosmetics, ointments or drugs have been increased and their careless usage induced detrimental effect on health. We developed simultaneous analytical method using TLC, HPLC and LC/MS for the identification of 40 corticosteroids. 34 corticosteroids were well separated in HPLC with isocratic mode and remaining 6 drugs were also separated with gradient mode. All of the 40 corticosteroids were detected in negative mode in LC/MS. Halcinonide, prednisolone, triamcinolone acetonide and methylprednisolone hemisuccinate were detected in real samples.

시간 정보를 활용한 동영상 파일 복원 기법 (Recovery Corrupted Video Files using Time Information)

  • 나기현;심규선;변준석;김은수;이중
    • 한국멀티미디어학회논문지
    • /
    • 제18권12호
    • /
    • pp.1492-1500
    • /
    • 2015
  • In recent crime scene, there is the captured crime scene video at least one. So video files recorded on storage media often provide important evidence. Criminals often attempt to destroy storage saved crime scene video. For this reason recovery of a damaged or deleted video file is important to resolve criminal cases in aspects of digital forensic. In the recent, there is a study to recover video file based on video frames, but it is very poor time efficiency when the connecting video frames. This paper proposed advanced frame-based recovery technique of a damaged video files using time information. We suggest a new connecting algorithm to connect video frames using recorded time information in front of video frame. We also evaluate performance in aspects of time and experiment result shows that proposed method improves performance.

119 구급대원의 법의학 지식에 대한 연구 (Assessing the forensic knowledge of 119 emergency medical technicians)

  • 이희영;문준동
    • 한국응급구조학회지
    • /
    • 제23권2호
    • /
    • pp.75-86
    • /
    • 2019
  • Purpose: It is crucial that 119 emergency medical technician (EMT) have adequate knowledge regarding forensic science. This study aimed to assess the forensic knowledge of EMTs in the Republic of Korea. Methods: This study was conducted on EMTs of five fire stations in D metropolitan city between August 6 and August 13, 2018. A questionnaire consisting of items on crime-related incident recognition (i.e., mechanical asphyxiation, trauma, sex crimes, and child abuse), forensic evidence management (i.e., evidence collection, preservation, and recording) was administered to the participants. Finally, 119 questionnaires were analyzed. Results: The ratio of correct answers for crime-related incidents recognition was 55.82%, which was lower than that for forensic evidence management(84.5%). In particular, the scores for the type of neck compression(16.5%) and wound assessment(44.0%) were low. The percentage of correct answers for forensic evidence management was 78.4% for evidence collection, 84.4% for evidence preservation, and 90.6% for evidence recording. Previous forensic education experience was not a significant variable. Conclusion: Specific and practical forensic science education on perception of crime-related incident, including asphyxia and wound identification, and forensic evidence collection is needed.

Cu-Zn 황동에서 수소가 탈아연 부식에 미치는 영향 (Effect of Hydrogen on Dezincification of Cu-Zn Brass)

  • 최병학;이범규;장현수;전우일;박용성;임재균;이진희;박찬성;김진표
    • 한국재료학회지
    • /
    • 제27권3호
    • /
    • pp.172-178
    • /
    • 2017
  • The aim of this study is to consider the effect hydrogen on dezincification behavior of Cu-Zn alloys. The investigations include microstructural observations with scanning electron microscope and chemical composition analysis with energy dispersive spectrometer. The dezincification layer was found to occur in high pressure hydrogen atmosphere, not in air atmosphere. In addition, the layers penetrated into the inner side along the grain boundaries in the case of hydrogen condition. The shape of the dezincification layers was porous because of Zn dissolution from the ${\alpha}$ or ${\beta}$ phase. In the case of stress corrosion cracks formed in the Cu-Zn microstructure, the dezincification phenomenon with porous voids was also accompanied by grain boundary cracking.