• Title/Summary/Keyword: National Disaster

Search Result 3,008, Processing Time 0.029 seconds

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

Forecasting Brown Planthopper Infestation in Korea using Statistical Models based on Climatic tele-connections (기후 원격상관 기반 통계모형을 활용한 국내 벼멸구 발생 예측)

  • Kim, Kwang-Hyung;Cho, Jeapil;Lee, Yong-Hwan
    • Korean journal of applied entomology
    • /
    • v.55 no.2
    • /
    • pp.139-148
    • /
    • 2016
  • A seasonal outlook for crop insect pests is most valuable when it provides accurate information for timely management decisions. In this study, we investigated probable tele-connections between climatic phenomena and pest infestations in Korea using a statistical method. A rice insect pest, brown planthopper (BPH), was selected because of its migration characteristics, which fits well with the concept of our statistical modelling - utilizing a long-term, multi-regional influence of selected climatic phenomena to predict a dominant biological event at certain time and place. Variables of the seasonal climate forecast from 10 climate models were used as a predictor, and annual infestation area for BPH as a predictand in the statistical analyses. The Moving Window Regression model showed high correlation between the national infestation trends of BPH in South Korea and selected tempo-spatial climatic variables along with its sequential migration path. Overall, the statistical models developed in this study showed a promising predictability for BPH infestation in Korea, although the dynamical relationships between the infestation and selected climatic phenomena need to be further elucidated.

A Case Study on the Construction of 3D Geo-spatial Information for Digital Twin Implementation (디지털 트윈 구현을 위한 3차원 공간정보 구축사례 연구)

  • KIM, Seung-Yub;LEE, Ho-Hyun;CHOI, Eun-Soo;GO, Je-Ung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.146-160
    • /
    • 2020
  • In the 4th industrial revolution, research on solving urban problems using ICT technology is emerging. Representatively, research is being conducted mainly focusing on smart cities. 3D geo-spatial. Various case studies on smart cities are being conducted to solve urban problems, and in order to effectively implement smart cities, it is implemented on the basis of a digital twin interconnecting physical and virtual environments. To implement a digital twin, the concept of space is essential, and spatial information that composes the real world is also essential. Therefore, in order to implement the digital twin, this study conducted a study on the construction and modeling of 3D geo-spatial information based on the national spatial information establishment regulations and the international standard CityGML for buildings, water facilities, and transportation facilities in Jeonju. In Jeonju, the research area, the LOD was defined, and the possibility of digital twin based on geo-spatial information was determined through data collection, analysis, and construction for each detail. In this study, it is meaningful that a plan to construct geo-spatial information for the implementation of a digital twin is presented, and the result of the construction is modeled as an urban standard model. The results of study are expected to be used as reference for detailed construction plans and standard establishment by governments and local governments promoting smart city and digital twin construction in the future.

A Case Study on the Implementation of Integrated Operation System of the Nakdong River Estuary Barrage Due to the Drainage Gate Extension (낙동강 하굿둑의 배수문 증설에 따른 통합운영시스템의 구축 사례에 대한 연구)

  • Kim, Seokju;Lim, Taesoo;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.1
    • /
    • pp.183-199
    • /
    • 2015
  • Due to the Four Major Rivers Restoration Project, Nakdong River Estuary Barrage's designed flood quantity has been largely increased, and this has caused to construct several drainage gates at the right side of Eulsukdo island to secure the safety of downstream river area. For successful functioning of Nakdong River Estuary Barrage, such as flood control, disaster prevention, and the securing of sufficient water capacity, drainage gates at the both sides of island have to operate systematically and reliably. To manage this under restricted personnel and resources, we have implemented the IOS (Integrated Operation System) by integrating previous facilities and resources via information and communication technologies. The IOS has been designed to have higher availability and fault tolerance to function continuously even with the partial system's failure under the emergency situation like flood. Operators can use the system easily and acknowledge alarms of facilities through its IWS (Integrated Warning System) earlier. Preparing for Integrated Water Resources Management and Smart Water Grid, the architecture of IOS conformed to open system standards which will be helpful to link with the other systems easily.

A Study on Income Expansion Plan for the Elderly according to Income Security Policy (소득보장정책에 따른 노후소득 확충방안에 관한 연구)

  • Kim, Nam-Jung;Choi, Young-Su
    • Industry Promotion Research
    • /
    • v.5 no.3
    • /
    • pp.23-29
    • /
    • 2020
  • In order to enrich the lives of senior citizens, this study suggested measures to increase income for the elderly by strengthening the current income security policies. Income security is a policy that guarantees income to maintain a certain standard of living. It is a policy that guarantees income to maintain a certain standard of living when income is suspended due to unemployment, disease, or disaster, or when income is lost due to retirement or death of a dependent due to old age, or when expenditure accompanying birth, death, etc. occurs. According to the study, measures to expand old-age income security are as follows. First, a phased increase in basic pension for the guarantee of old-age income is needed. Second, the income security function of the National Pension Service should be further strengthened. Third, a multi-layered old-age income security system should be established. Fourth, the government should continue to push for the expansion of works for the elderly. In conclusion, in order to strengthen the income security policy for the elderly, a reexamination of the current income guarantee system for the elderly is needed first. Then, it will be necessary to propose measures to gradually guarantee income for the elderly.

An Experimental Study on Bearing Capacity of Drilled Shaft with Mid-size (중구경 현장타설말뚝의 지지력 특성에 관한 실험적 연구)

  • Lee, Kwang-Wu;You, Seung-Kyong;Park, Jeong-Jun;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.263-272
    • /
    • 2019
  • This paper describes the results of bearing capacity using field loading test of pile, in order to extend the applicability of drilled shaft with mid-size, and the results were compared with the prediction results of design bearing capacity by empirical formular. The static load test result showed that the allowable bearing capacity of high pile strength was about 2.4 times higher than that of low pile strength. The dynamic load test result showed that the allowable bearing capacity of high pile strength was about 1.4 times~1.5 times higher than that of low pile strength. The comparison result of allowable bearing capacity between static and dynamic load test showed that the difference of allowable load ranged from 3% to 6% under the same settlement conditions. As a result of comparing the ultimate bearing capacity by load test and design bearing capacity, it was found that the FHWA proposed equation could be more reasonable than the other proposed equation in load sharing ratios of end bearing and skin friction.

Analysis of Response Characteristics According to Permanent Displacement in Seismic Slope (지진시 비탈면의 영구변위 발생에 따른 응답특성 분석)

  • Ahn, Jae-Kwang;Park, Sangki;Kim, Wooseok;Son, Su-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.135-145
    • /
    • 2019
  • The slope collapse can be classified into internal and external factors. Internal factors are engineering factors inherent in the formation of slopes such as soil depth, slope angle, shear strength of soil, and external factors are external loading such as earthquakes. The external factor for earthquake can be expressed by various values such as peak ground acceleration (PGA), peak ground velocity (PGV), Arias coefficient (I), natural period (Tp), and spectral acceleration (SaT=1.0). Specially, PGA is the most typical value that defines the magnitude of the ground motion of an earthquake. However, it is not enough to consider the displacement in the slope which depends on the duration of the earthquake even if the vibration has the same peak ground acceleration. In this study, numerical analysis of two-dimensional plane strain conditions was performed on engineered block, and slope responses due to seismic motion of scaling PGA to 0.2 g various event scenarios was analyzed. As a result, the response of slope is different depending on the presence or absence of sliding block; it is shown that slope response depend on the seismic wave triggering sliding block than the input motion factors.

The big data method for flash flood warning (돌발홍수 예보를 위한 빅데이터 분석방법)

  • Park, Dain;Yoon, Sanghoo
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.245-250
    • /
    • 2017
  • Flash floods is defined as the flooding of intense rainfall over a relatively small area that flows through river and valley rapidly in short time with no advance warning. So that it can cause damage property and casuality. This study is to establish the flash-flood warning system using 38 accident data, reported from the National Disaster Information Center and Land Surface Model(TOPLATS) between 2009 and 2012. Three variables were used in the Land Surface Model: precipitation, soil moisture, and surface runoff. The three variables of 6 hours preceding flash flood were reduced to 3 factors through factor analysis. Decision tree, random forest, Naive Bayes, Support Vector Machine, and logistic regression model are considered as big data methods. The prediction performance was evaluated by comparison of Accuracy, Kappa, TP Rate, FP Rate and F-Measure. The best method was suggested based on reproducibility evaluation at the each points of flash flood occurrence and predicted count versus actual count using 4 years data.

A numerical study of the effects of the ventilation velocity on the thermal characteristics in underground utility tunnel (지하공동구 터널내 풍속 변화에 따른 열특성에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Ra, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • In this research, thermal design data such as heat transfer coefficient on the wall surface required for ventilation system design which is to prevent the temperature rise in the underground utility tunnel that three sides are adjoined with the ground was investigated in numerical analalysis. The numerical model has been devised including the tunnel lining of the underground utility tunnel in order to take account for the heat transfer in the tunnel walls. The air temperature in the tunnel, wall temperature, and the heating value through the wall based on heating value(117~468 kW/km) of the power cable installed in the tunnel and the wind speed in the tunnel(0.5~4.0 m/s) were calculated by CFD simulation. In addition, the wall heat transfer coefficient was computed from the results analysis, and the limit distance used to keep the air temperature in the tunnel stable was examined through the research. The convective heat transfer coefficient at the wall surface shows unstable pattern at the inlet area. However, it converges to a constant value beyond approximately 100 meter. The tunnel wall heat transfer coefficient is $3.1{\sim}9.16W/m^2^{\circ}C$ depending on the wind speed, and following is the dimensionless number:$Nu=1.081Re^{0.4927}({\mu}/{\mu}_w)^{0.14}$. This study has suggested the prediction model of temperature in the tunnel based on the thermal resistance analysis technique, and it is appraised that deviation can be used in the range of 3% estimation.

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.