• Title/Summary/Keyword: National Artifact

Search Result 283, Processing Time 0.026 seconds

Mind control interface technology for the military control instrument (군사용 제어기기를 위한 마인드 컨트롤 인터페이스 기술)

  • Kim, Eung-Su
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.249-267
    • /
    • 2003
  • EEG is an electrical signal, which occurs during information processing in the brain. These EEG signals have been used clinically, but nowadays we are mainly studying Brain-Computer Interface (BCI) such as interfacing with a computer through the EEG, controlling the machine through the EEG. The ultimate purpose of BCI study is specifying the EEG at various mental states so as to control the computer and machine. This research makes the controlling system of directions with the artifact that are generated from the subject's will, for the purpose of controlling the machine correctly and reliably. We made the system like this. First, we select the particular artifact among the EEG mixed with artifact, then, recognize and classify the signals' pattern, then, change the signals to general signals that can be used by the controlling system of directions.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT (Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가)

  • Kim, Young-kuen;Yang, Sook;Wang, Tae-uk
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.79-85
    • /
    • 2020
  • The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.

Design of an Adaptive Noise Canceller for the Motion Artifact Removal of a Pulse Oximetry Signal (펄스 옥시미터의 동잡음 제거 필터 설계)

  • Kim, Do-Young;Kim, Ill-Hwan
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.89-93
    • /
    • 2006
  • Pulse oximetry, which monitors non-invasively the oxygen saturation in blood, is influenced by patient's respiration, movement or a factor of an environment. Specially, it's difficult to measure a PPG (Photoplethsmography) signal from the moving patient because of the motion artifact. Accordingly, it is required to extract the pure PPG signal from the PPG signal to measure oxygen saturation. In this paper, we propose an adaptive noise canceller to improve the performance of motion artifact removal. Then we design a hardware system for real time monitoring of the oxygen saturation. The proposed algorithm estimates the slope of transition rate between two different wavelength signals.

  • PDF

Study on the Conservation of Scale Armor Using Duplication Technique - Focused on the Case of the Conservation Treatment of the Excavated Artifact from Jinyoung 2-Area, Gimhae - (복제 기법을 이용한 찰갑의 보존처리 - 김해 진영 2지구 출토품의 보존처리 사례를 중심으로 -)

  • Kim, Dong Min;Park, Jung Hyeok;Cho, Hyun Kyung;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.75-86
    • /
    • 2015
  • A scale Armor is usually excavated in a scattered form weakened by corrosion after its burial. Therefore, they should be brought into the indoor in a safe environment for the on-site conservation treatment as it was excavated. They should be placed on a stable support with a reinforced base in the indoor treatment. In this process, the bottom surface which can not be observed after the conservation treatment is placed for a record by actual survey and photography. But this method had a limit on figuring out the whole aspects of the artifact. For compensating the defect, duplication of the artifact was considered as an alternative method for the previous two methods in the case of conservation of the scale Armor from Jinyoung 2-Area, Gimhae. Neck guard was excavated in a distorted form by the earth pressure, and was hard to recognize the original shape. However, whole real material of its original form was secured through the combination of each duplicated lamellae. Throughout the application of the duplication technique in the process of conservation of scale Armor and neck guard, it could secure the real material of the bottom surface and elevate the understanding of the artifact. Moreover, a constitution of the armor could be identified more effectively.

Photon Defects due to Residual Barium in the Colon Simulating Cold Bone Metastasis in Two Patients with Extraskeletal Cancer (골격외 종양 환자에서 냉소 골전이와 유사하게 보인 잔류 바리움에 의한 광자 결손)

  • Lim, Seok-Tae;Kim, Min-Woo;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.314-316
    • /
    • 2002
  • One of common causes of cold defects on bone scintigraphy is an attenuation artifact. Cold defects can be produced by belt buckles, buttons, earring, necklaces, or other metal objects. Cold lesions in the abdomen are also produced by retained barium in the gastrointestinal tract after recent barium studies. We observed artifacts due to retained barium in the colon on bone scintigraphy, which simulated cold bone metastases in two patients with extraskeletal cancer.

Uterine Doughnut by Intrauterine Device-induced Photon Attenuation on Three-Phase Bone Scintigraphy : Artifact (삼상 골신티그래피상 자궁내장치의 광자감쇠현상에 의해 생긴 Uterine Doughnut: 인공물)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.68-69
    • /
    • 2007
  • A 44-year-old female underwent three-phase bone scintigraphy for an evaluation of right hip joint pain. The blood-flow and blood-pool images show a pelvic blush with a photopenic center (doughnut) prior to bladder filling. On the three hour delayed image, the pelvic uptake disappeared. The scintigraphic findings indicated the possibility of an early pregnancy. However, plain radiography demonstrated an intrauterine device. A uterine doughnut developed as a result of photon attenuation of intrauterine device.

Multitoning Method Based on Arrangement of Ink Distribution for Smooth Tone Transition (부드러운 계조 변화를 위한 잉크 분포 조절 기반의 멀티토닝 방법)

  • Park, Tae-Yong;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.17-25
    • /
    • 2007
  • Multilevel inkjet printer employs multiple ink droplets with variable dot size and/or different concentrations intended to preserve high fidelity color reproduction and the appearance of continuous tone. A variety of research efforts on multitoning techniques has progressed toward better image quality. However, banding artifacts appear due to the same dot distributions near the printable output levels. This results in discontinuity and visually unpleasing output, especially at the smooth tone transition region. In this paper, to reduce the banding artifacts, a multitoning method to arrange ink distribution by controlling the blending proportion of adjacent output pixels based on an improved threshold scaling function is proposed. Ink distributions across the banding regions are changed according to two factors of the threshold scaling function because these factors handle the blending point of adjacent output pixel. Therefore, 8 observers, subjectively investigated ink distributions around the printable output levels for a set of the improved threshold scaling function. For a threshold scaling function with the specific factor values, we can achieve smoother visual transition. In the experiment, the proposed method showed a reduction of banding artifacts in both u-ay and color image and represented better Performance of color reproduction.

On-site Conservation Treatment of the Beaker-shaped Pottery from Yori, Hyangnam, Hwaseong (화성 향남 요리 출토 심발형 토기 수습과 보존처리)

  • Kwon, Ohyoung;Ham, Chulhee;Lee, Sunmyoung
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.494-504
    • /
    • 2020
  • Ten historic sites (denoted as A- J in this study) of a tomb were found during the construction of the east-west expressway in District 2 of Hyangnam, Hwaseong, which is implemented by the Gyeonggi-do headquarters of the Korea Land & Housing Corporation. Thetombswere first detected at siteH, and further investigations revealed various tombs from the Three Kingdoms period; artifacts such as gilt-bronze shoes and caps were excavated from wooden coffins in the tombs. The pottery examined in this study was the only pottery artifact excavated from the site. Its raw clay was soft and loose, reddish brown, and had quartz and feldspar particles of < 1 mm, which appeared to have been added as reinforcing agents. The firing temperature of the pottery was estimated to be under 800-870 ℃ as the mica remains and tridimite, which is the phase transition mineral of quartz, was not produced; a slight endothermic peak was also detected because of the hydration of sericite at 800 ℃. The condition of the artifact was severely weakened because of various factors, such as soil pressure from the stratum formed over the site and repeated freezing and thawing. The artifact could not be collected alone, and thus, surrounding soil that had attached to the artifact was also collected; the artifact was transported to the laboratory and conservation treatment was conducted in a safe and systematic manner.