• Title/Summary/Keyword: Nasal Airway

Search Result 169, Processing Time 0.028 seconds

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Methacholine Responsiveness of Bronchial and Extrathoracic Airway in Patients with Chronic Cough (만성 기침 환자에서 기관지와 흉곽외 기도의 Methacholine 유발검사의 의의)

  • Shim, Jae-Jeong;Kim, Je-Hyeong;Lee, Sung-Yong;Kwan, Young-Hwan;Lee, So-Ra;Lee,, Sang-Yeub;Lee, Sang-Hwa;Suh, Jung-Kyung;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.853-860
    • /
    • 1997
  • Background : Chronic cough, defined as a cough persisting for three weeks or longer, is a common symptom for which outpatient care is sought. The most common etiologies of chronic cough are postnasal drip, asthma, and gastroesophageal reflux. Methacholine challenge is a useful diagnostic study in the evaulation of chronic cough, particularly useful in chronic cough patients with asthmatic symptom. Patients with chronic cough may have dysfunction of bronchial and extrathoracic airways. To evaluate if dysfunction of the bronchial and extrathoracic airways causes chronic cough, we assessed bronchial (BHR) and extrathoracic airway (EAHR) responsiveness to inhaled methacholine in patients with chronic cough. Method : 111 patients with chronic cough were enrolled in our study. Enrolled patients had no recorded diagnosis of asthma, bronchopulmonary disease, hypertension, heart disease or systemic disease and no current treatment with bronchodilator or corticosteroid. Enrolled patients consisted of 46 patients with cough alone, 24 patients with wheeze, 22 patients with dyspnea, 19 patients with wheeze and dyspnea. The inhaled methacholine concentrations causing a 20% fall in forced expiratory volume in 1s($PC_{20}FEV_1$) and 25% fall in maximal mid-inspiratory flow ($PC_{25}MIF_{50}$) were used as bronchial and extra thoracic hyperresponsiveness. Results : There were four response patterns to methacholine challenge study : BHR in 27 patients, EAHR in 16 patients, combined BHR and EAHR in 8 patients, and no hyperresponsiveness in 60 patients. In patients with cough alone, there were BHR in 3 patients, EAHR in 9 patients, and combined BHR and EAHR in 2 patients. In patients with wheeze and/or dyspnea, there were BHR in 24 patients, EAHR in 7 patients, and BHR and EAHR in 6 patients. Compared with patients with wheeze and/or dyspnea, patients with cough alone had more common EAHR than BHR. In patients with wheeze and/or dyspnea, BHR was more common than EAHR. Conclusion : These results show that among patients with hyperresponsiveness to methacholine, those with dyspnea and/or wheezing had mainly bronchial hyperresponsiveness, whereas those with chronic cough alone had mainly extrathoracic airway hyperresponsiveness.

  • PDF

Sleep Fragementation Decreases during the nCPAP Titration Night in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 압력 처방 검사 시 나타나는 수면분절의 감소)

  • Lee, Jin-Seong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Objectives: Obstructive sleep apnea syndrome (OSAS) not only causes respiratory disturbances during sleep but also decreases the quality of nocturnal sleep through sleep fragmentation and sleep structure change. We aimed at comparing the changes in sleep fragmentation and structure between baseline (diagnostic) nocturnal polysomnography (NPSG) and nCPAP (nasal continuous positive airway pressure) titration trial. Methods: One hundred and three patients with a baseline night of respiratory disturbance index (RDI) of 5 or greater and reduced RDI score during nCPAP titration night were retrospectively selected for the study. Sleep fragementation and sleep structure between baseline NPSG and the NPSG during nCPAP titration were compared. Sleep fragmentation index (SFI) was defined as the total number of awakenings and shifts to stage 1 sleep divided by the total sleep time in hour. SFI and other polysomnographic parameters were statistically compared between the two nights. Results: SFI during baseline NPSG and nCPAP titration nights were $29.0{\pm}13.8$ and $15.2{\pm}8.8$, respectively, indicating a significant SFI decrease during nCPAP titration (t=9.7, p<0.01). SFI showed significant negative correlations with sleep efficiency (r=-0.60, p<0.01) and total sleep time (r=-0.45, p<0.01) and a positive correlation with RDI (r=0.28, p<0.01). Conclusion: Use of nCPAP, even during the titration, significantly decreases sleep fragmentation and improves sleep structure in OSAS patients. We suggest that SFI may be utilized as a measure of assessing OSAS severity and nCPAP efficacy.

  • PDF

Primary Radiation Therapy of Polymorhic Reticulosis (다형성 세망증의 방사선 치료성적)

  • Kim Jae Sung;Yun Hyoung Geun;Ahn Yong Chan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.111-116
    • /
    • 1991
  • From 1979 to 1987, 33 patients with polymorphic reticulosis (PMR) limited in the upper airway were treated with primary radiation therapy and the analysis of treatment results was undertaken. Systemic symptoms such as fever, night sweats, and weight ioss were noted in $48\%$. The nasal cavity was most frequently involved $(85\%)$, although involvement of PNS $(33\%)$ and palate $(30\%)$ was not uncommon. The 5 and 10 year actuarial survival rates were $47\%\;and\;40\%$, respectively. The difference in NSD between patients with in-field failure and those without it was significant statistically. Also, field size was significantly smaller in patients with marginal failure than those without it. During the follow-up period, systemic failure was found in S patients (diffuse histiocytic Iymphoma in 4, histiocytic medullary reticulosis in 1). In this study, we can suggest that total radiation dose of at least 4500 cGy with generous treatment volume should be delivered to achieve better local control and that the developement of an effective systemic chemotherapeutic regimen is required to improve the survival after systemic relapse.

  • PDF

Deep Sedation for Palate Alginate Impression Procedure in a Post-Fontan Procedure Patient with Mental Retardation (Fontan 수술을 받은 정신지체 소아에서 인상채득을 위해 시행한 깊은 진정)

  • Lee, Jung-Man;Seo, Kwang-Suk;Kim, Hyun-Jeong;Shin, Soon-Young;Shin, Teo-Jeon
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • The Fontan operation is a heart operation used to treat complex congenital heart defects like tricuspid atresia, hypoplastic left heart syndrome, pulmonary atresia and single ventricle. A single ventricle is dedicated to pumping oxygenated blood to the systemic circulation and the entire systemic venous return reaches the pulmonary arterial system without the direct influence of a pumping chamber. In the patient with Fontan operation, it is important to achieve adequate pulmonary blood flow and cardiac output in anesthetic management. In this case, a 10-year-old boy (19.6 kg, 114 cm) with cleft palate, cerebral palsy and severe mental retardation, who underwent a Fontan operation when he was 4 years old, was presented for deep sedation. Because he was suffering from eating disorder with cleft palate, the orthodontist and the plastic surgeon planned to insert intraoral orthodontic device before cleft palate repair. But it was impossible to open his mouth for alginate impression procedure. After careful pre-anesthesia evaluation we planned to administer deep sedation with propofol infusion. After Intravenous catheter insertion, we started propofol intravenous infusion with the formula of a loading dose of 1.0 mg/kg followed by an infusion rate of 6.0 mg/kg/hr with syringe pump. His blood pressure was remained around 80/40 mmHg after loss of consciousness, but he could not maintain his airway patent. So we lowered the infusion rate to 3.0 mg/kg/hr, immediately. The oxygen saturation was maintained above 95% with nasal oxygen supply, and blood pressure was maintained around 100-80/60-40 mmHg. After the sedation of 110 minutes with propofol (the infusion rate to 3.0-5.0 mg/kg/hr), he fully regained consciousness, and was discharged without complication after 1 hour observation. In case of post-Fontan patient, intravenous deep sedation with propofol was safe and effective method of behavioral management during dental treatment.

Semi-longitudinal study of adenoid and jaw growth of normal occlusal children aged 6 to 17 (6세에서 17세 사이의 정상 교합 아동의 아데노이드와 악골의 성장에 관한 준종단적 연구)

  • Yu, Hyung-Soeg;Park, Sun-Hyung;Choi, Eun-Bin;Mun, Je-Sang;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.699-712
    • /
    • 2000
  • Reduced nasal breathing can influence the growth at)d development of facial structures. It nay have many causes, and enlarged adenoid is the most frequent one. To investigate the effects of adenoids to jaw growth, we must first understand the normal growth of adenoids and jaws, and the relationship between size of adenoids and the values lot the jaw variables. The purpose of this study is to present a more objective standard of nasopharyngeal size and jaw dimension at each bone age, by using Cervical Vertebrae Maturation Index(CYMI) of Hassel, from normal occlusion children aged 6 to 17. The results of this study suggests as follows : 1. At same bone age, female's chronologic age was about 2 year older than male. 2. There was a growth peak of nasopharyngeal(NP) height and depth between CVMI 1 to 2 in male, hut in female NP height and depth gradually increase through CVMI 1 to 6. 3. Relative airway of nasopharynx increases the most between CVMI 1 to 2 period in both gender 4. Among adenoid measurements, Ad2-related variables and upper pharynx, and among dentofacial measurements inter canine width in both arch, maxillary intermolar width and palatal depth had high correlation coefficient with adenoid percentage.

  • PDF

Voice Quality in Patients with Asthma (천식환자에서의 음성의 질)

  • Han, Myung-Woul;Kim, Seong-Tae;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.63-67
    • /
    • 2009
  • Background and Objectives: In patients with asthma, increased obstruction and resistance of airway result in impairment in the generation of voice. Allergy and nasal polyposis, which are frequently observed in patients with asthma, are other factors that affect the vocal performance. Bronchodilators and steroids are commonly used in the treatment of asthma, and these agents also have been reported to be associated with voice changes. The aim of this study is to evaluate the voice quality in patients with mild to-moderate asthma by subjective and objective methods. Materials and Methods: A total of 36 patients with asthma established in the Department of Respiratory Medicine were included in this study. 23 were women and 13 were men, with a mean age of 51.7 years. The average duration of asthma was 77.0 months. All patients had mild-to moderate asthma. Acoustic and aerodynamic analyses were performed and the movements of the vocal cords were examined by videolaryngostroboscopy (VLS). Voice Handicap Index (VHI) and GRABS scales were used for subjective evaluations. Results: 50% of patients suffered from dysphonia and FO was 119.3${\pm}$23.7 Hz in male and 198.2${\pm}$18.4 Hz in female patients. There were no significant differences in average shimmer and NHR between females (4.90${\pm}$2.95% ; 0.1O${\pm}$0.04 dB) and males (4.64${\pm}$2.45% ; 0.20${\pm}$0.15 dB). However, the value of jitter was greater for females (2.60${\pm}$1.92%) than for males (1.21${\pm}$0.84%). The VHI score was above the normal limit in 35%, and VLS findings were shown diverse abnormality in 89% asthmatics from mucosal change to hyperfunction of supragottis and contact granuloma. But duration of illness and steroid dose did not correlate with these findings. Conclusion: Subjective and objective abnormality was shown in more than 50% of asthmatic patients. We suggest that persons who suffer from asthma should be examined for possible voice disorders by laryngologist. Additionally, appropriate medical care and voice therapy should be provided for those who have voice disorders associated with asthma.

  • PDF

Influence of Sleep-Related Breathing Disorders on Changes of Cardiovascular Function (수면과 관련된 호흡장애가 심혈관계의 기능 변화에 미치는 영향)

  • Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.129-139
    • /
    • 1997
  • The data collected to date indicate that sleep-related breathing disorders, including sleep-disordered breathing(sleep apnea) and underlying respiratory system diseases, are one of the important risk factors for cardiovascular dysfunction. Sleep-disordered breathing(sleep apnea) is now recognized as one of the leading causes of systemic hypertension, cardiac arrhythmias, coronary heart disease, pulmonary hypertension, right heart failure, and stroke. Sleep may exert a profound effect on breathing in patients with underlying respiratory system disease including bronchopumonary diseases, chest wall abnormalities, central alveolar hypoventilation syndromes or respiratory neuromuscular disorders. Chronic hypoxia and hypercapnia in these patients may accelerate the development of long term cardiovascular complications such as cardiac arrhythmias, pulmonary hypertension, and right heart failure(cor pulmonale). Several recent studies reported that sleep-related breathing disorders are associated with long-term cardiovascular morbidity and mortality. Careful assessment of respiratory and cardiovascular function in these patients is critical. Aggressive and highly effective treatment of sleep-related breathing disorders using tracheostomy, mechanical ventilation, nasal continuous positive airway pressure therapy(nCPAP), intercurrent oxygen therapy or other interventions can reduce the prevalence of cardiovascular dysfunction and the long-term mortality.

  • PDF

Risk factors affecting the difficulty of fiberoptic nasotracheal intubation

  • Rhee, Seung-Hyun;Yun, Hye Joo;Kim, Jieun;Karm, Myong-Hwan;Ryoo, Seung-Hwa;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.5
    • /
    • pp.293-301
    • /
    • 2020
  • Background: The success rate of intubation under direct laryngoscopy is greatly influenced by laryngoscopic grade using the Cormack-Lehane classification. However, it is not known whether grade under direct laryngoscopy can also affects the success rate of nasotracheal intubation using a fiberoptic bronchoscpe, so this study investigated the same. In addition, we investigated other factors that influence the success rate of fiberoptic nasotracheal intubation (FNI). Methods: FNI was performed by 18 anesthesiology residents under general anesthesia in patients over 15 years of age who underwent elective oral and maxillofacial operations. In all patients, the Mallampati grade was measured. Laryngeal view grade under direct laryngoscopy, and the degree of secretion and bleeding in the oral cavity was measured and divided into 3 grades. The time required for successful FNI was measured. If the intubation time was > 5 minutes, it was evaluated as a failure and the airway was managed by another method. The failure rate was evaluated using appropriate statistical method. Receiver operating characteristic (ROC) curves and area under the curve (AUC) were also measured. Results: A total of 650 patients were included in the study, and the failure rate of FNI was 4.5%. The patient's sex, age, height, weight, Mallampati, and laryngoscopic view grade did not affect the success rate of FNI (P > 0.05). BMI, the number of FNI performed by residents (P = 0.03), secretion (P < 0.001), and bleeding (P < 0.001) grades influenced the success rate. The AUCs of bleeding and secretion were 0.864 and 0.798, respectively, but the AUC of BMI, the number of FNI performed by residents, Mallampati, and laryngoscopic view grade were 0.527, 0.616, 0.614, and 0.544, respectively. Conclusion: Unlike in intubation under direct laryngoscopy, in the case of FNI, oral secretion and nasal bleeding had a significant effect on FNI difficulty than Mallampati grade or Laryngeal view grade.

The Change of Cell Distribution in the lung and the Expression Pattern of IL-4 and IL-10 in Asthma Induced Mouse (천식유발 마우스에서의 폐 내 세포조성 변화와 IL-4 및 IL-10의 발현 양상)

  • Lee, Soo-Jin;Park, Se-Jong;Li, Tian-Zhu;Jang, Yang-Ho;Choe, Nong-Hoon
    • Journal of Life Science
    • /
    • v.16 no.5
    • /
    • pp.780-787
    • /
    • 2006
  • Asthma is a chronic inflammatory disorder of the airways, which characterized by bronchial hyperresponsiveness, reversible airflow limitation and respiratory symptoms. Internationally, the prevalence of asthma has been increased over last 3 decades. Recently, several studies of asthma have been reported with gradually increasing importance. To tesify the hypothesis that interleukin (IL)-4 and IL-10 may be an important determinant of the severity of airway inflammation, their expression was studied in mouse model of asthma. BALB/c mouse, IL-4 Knockout (KO) mouse and IL-10 KO mouse were sensitized with intraperitoneal injection of ovalbumin adsorbed to aluminum potassium sulfate, followed by challenges with intranasal ovalbumin on 3 consecutive days. The severity of pulmonary inflammation was assessed by eosinophilia in BAL fluid, number of total BAL cells, histopathological changes in lung tissues, and immunohistochemical staining against IL-4 and IL-10. In BAL fluid, the number of total cells was significantly increased in asthma induced mouse compare to the control. In asthma induced mouse, eosinophil was increased to 56% and neutrophil was 0.2%. In H &E stains, eosinophilic infiltration and epithelium hyperplasia were clearly noticed in asthma induced mouse. In immunohistochemical staining for IL-4 and IL-10, there was no positive reaction in control group. However, very strong reactions were appeared in asthma induced group. In this research, IL-4 and IL-10, which seem to play a central role in allergic asthma, KO mouse was utilized to test the causative relationship between airway inflammation and role of specific cytokine. Asthma induced IL-4 and IL-10 KO mice showed much decreased inflammatory reactions in the number of total BAL cells, in eosinophilic infiltration, and in immunohistochemical stains against diverse inflammatory proteins. These results suggest that IL-4 and IL-10 increase the asthmatic reactions in vivo mice model.