• 제목/요약/키워드: Nanofiltration

검색결과 208건 처리시간 0.025초

저압나노여과에 의한 각종 중금속의 제거 특성 (Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration)

  • 오정익;김한승;김충환
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.

활성탄과 Membrane을 이용한 수처리효과에 관한연구 (A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes)

  • 김영진;김영규;정문호
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF

정수처리에 이용되는 나노여과막시스템의 성능예측방법 확립 (Treatability Prediction Method for Nanofiltration Systems in Drinking Water Treatments)

  • 강미아;伊藤雅喜
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.572-581
    • /
    • 2005
  • This research is conducted to develop predictable method of real scale nanofiltration treatability with small scale nanofiltration experiments. As a result of comparing calculated values with measured values, they are in a good agreement for the concentrations in filtered water and concentrated water. The results of that are not affected by change of system recovery from 20% to 95%. The proposed method is produced using constant recovery of elements, that is, no considering the pressure change. we can predict filtrated flux and contaminant concentrations with the method. The method has the following steps. (1) Calculate recovery of each element with water quality level after fixing recovery elements, (2) Predict system recovery with recovery of elements in 1, 2, 3, and 4 banks, (3) Run small scale nanofiltration experiments in predicted water quality and (4) Simulate large scale nanofiltration system for forecasting actual water quality. As the cost for nanofiltration pretest will reduced if we use the proposed method, it will be a promising method for introducing nanofiltration to supply safe drinking water.

Development of Lactose-hydrolyzed Milk with Low Sweetness Using Nanofiltration

  • Choi, S.H.;Lee, S.-B.;Won, H.-R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권6호
    • /
    • pp.989-993
    • /
    • 2007
  • A lactose-hydrolyzed milk with low sweetness was developed using nanofiltration. Raw milk was treated with 0.03% ${\beta}$-galactosidase at $4^{\circ}C$ for 24 h to hydrolyze lactose partially. The resultant lactose-hydrolyzed milk containing 0.43% lactose was then concentrated using a nanofiltration membrane to reach concentration factor of 2.13. The concentration factors and coefficients of retention of milk components in nanofiltration were determined. The concentration factor of milk fat was 2.20 which was the highest of the milk components. The coefficient of retention of calcium and riboflavin was 0.96 and 0.76, respectively. However, the coefficient of retention of glucose, galactose, and sodium was 0.21, 0.15, and 0.22, respectively. Raw milk was treated with 0.1% ${\beta}$-galactosidase at $4^{\circ}C$ for 40 h to hydrolyze lactose fully and then concentrated to reach a concentration factor of 1.6 by using nanofiltration. The concentrated milk was reconstituted with water. The lactose-hydrolyzed milk had sweetness similar to milk. The compositional ratios of crude protein, calcium, sodium, and riboflavin of lactose-hydrolyzed nanofiltrated milk to those of raw milk were 99%, 97%, 77%, and 80%, respectively. This study showed that nanofiltration of lactose-hydrolyzed milk to remove galactose and glucose did not cause significant loss of calcium. The lactose-hydrolyzed nanofiltrated milk contained 0.06% lactose and had sweetness similar to milk.

폴리비닐알콜로 제조된 나노복합막 (Nanofiltration Composite Membranes Based on Poly(vinyl alcohol))

  • 오남운;제갈종건;이규호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.106-108
    • /
    • 1998
  • It has been proved by the study on nanofiltration with PVA dense membranes in our laboratory that the PVA is good material for the formation of chemically stable nanofiltration (NF) membranes. However, the PVA NF composite membranes prepared so far have rarely shown flux and rejection high enough for the commerciallyzation. The reasons for them would be the relatively thick thickness and improper crosslinking degree of the PVA active layers of the composite membranes. In this study, PVA composite membranes with improved nanofiltration properties have been prepared and characterized in terms of the morphology and permeation properties.

  • PDF

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

Development of Transport Parameters affecting on the Removal of Micro Organic Compounds such as Disinfection By-Products and Pharmaceutically Active Compounds by Low-Pressure Nanofiltration

  • Oh, Jeong-Ik;Yamamoto, Kazuo
    • Environmental Engineering Research
    • /
    • 제14권2호
    • /
    • pp.126-133
    • /
    • 2009
  • This study investigated the removal characteristics of various micro organic compounds by low-pressure nanofiltration membranes comprised of disinfection by products and pharmaceutically active compounds. The experimental removal of micro organic compounds by low-pressure nanofiltration membranes was compared with the transport model calculations, which consist of diffusion and convection terms including steric hindrance factor. The selected molecule from the disinfection byproducts and pharmaceutical active compounds showed a much lower removal than polysac-charides with a similar molecular size. However,the difference between model calculation and experimental removal of disinfection by-products and pharmaceutically active compounds could be corrected. The correlation of Ks with solute radius was further considered to clarity transport phenomena of micro organic solutes through nanofiltration membranes.

고분자 소재와 용매특성에 따른 유기용매 나노여과막 성능 분석 (Effects of Polymer Material and Solvent Properties on the Performance of Organic Solvent Nanofiltration Membranes)

  • 최지현;김정
    • 멤브레인
    • /
    • 제32권1호
    • /
    • pp.50-56
    • /
    • 2022
  • 본 연구에서는 유기용매용 나노여과막 (Organic Solvent Nanofiltration, OSN)의 유기용매 투과 및 분리성능을 분석하였다. 비극성용매에 적합한 Puramem (PM) 시리즈 분리막의 소재를 분석한 후 다양한 유기용매 분위기에서의 투과성능을 데드엔드셀로 측정하였다. PM 시리즈 분리막은 극성용매 대비 비극성용매에서 더 높은 투과도를 보였으며, 용질의 종류 및 분자량에 따라 매우 독특한 배제성능을 보이는 것을 확인하였다. 이는 기존 수처리에 적용되는 Solution-diffusion 투과모델이 OSN 투과모델에는 적합하지 않다는 것을 알 수 있으며, solvent-solute-membrane 간의 상관관계를 더 정확하게 반영할 수 있는 새로운 인자가 필요하다는 결론을 낼 수 있다.

표면 개질된 나노복합막의 투과 특성 (Permeation Properties of Surface Modified Nanofiltration Membrane)

  • 탁태문;박형규;장경국
    • 멤브레인
    • /
    • 제14권3호
    • /
    • pp.207-217
    • /
    • 2004
  • 본 연구에서는 복합막의 제조공법으로 가장 광범위하게 쓰이는 계면중합법을 이용하여 나노복합막을 제조하였다. Monomer의 농도 및 조성, curing 조건, 후처리 조건과 같은 복합막 제조조건과, 운전압력, 공급액의 농도와 같은 운전인자에 의한 막성능 변화를 조사하였고, 계면중합 과정중에 첨가제를 사용하여 막의 유효면적을 확대하여 투과유속을 증가시키고자 하였다. Monomer의 농도가 증가함에 따라 배제능은 일정하였지만 투과유속이 감소하였고, curing 온도가 증가함에 따라서는 오히려 안정적인 박막층의 형성이 저해되어서 배제능과 투과유속이 모두 감소하였고, curing 시간에 따른 막성능의 변화는 나타나지 않았다. Test solution의 농도가 올라감에 따라서 투과유속과 배제능 모두 감소하였으며, 운전압력이 증가함에 따라서는 배제능과 투과유속 모두 향상하는 경향을 보였다. 계면중합과정중에 사용하는 아민단량체(amine monomer) 중 방향족 다이아민(aromatic amine)인 MPD의 함량을 높임에 따라서 배제능은 증가하였지만 투과유속은 현저하게 떨어졌다. 첨가제의 농도에 따른 표면 거칠기 증가 경향은 MPD가 포함된 amine 조성일 때가 더 높았지만 투과유속은 piperazine만 단독으로 사용하였을 때보다 떨어졌다.

발효액 내 유기산의 효과적 회수를 위한 나노여과 분리막 (Preparation and Characterization of Nanofiltration Membranes for Recovery of Organic Acids from Fermentation Broth)

  • 황윤성;조영훈;박호범
    • 멤브레인
    • /
    • 제23권4호
    • /
    • pp.304-311
    • /
    • 2013
  • 발효공정으로부터 생산된 유기산의 회수를 위하여 나노여과 분리막 공정을 이용하는 경우 유기산을 제외한 발효액 내 존재하는 당, 단백질 등의 부산물을 배제하면서 유기산을 선택적으로 투과시킬 수 있는 나노여과막이 요구된다. 본 연구에서는 발효액으로부터 분자량이 상대적으로 작고 카르복실산기를 갖는 유기산의 효과적인 회수를 위하여 분리막 표면에 양전하를 도입하여 전기적 인력에 의해 젖산의 투과도를 향상시킬 수 있는 신규 나노여과 분리막을 제조하였다. 분리막 표면에 고분자 전해질 PEI (Polyethyleneimine)를 그라프팅시켜 제조된 분리막의 제타전위 측정 결과 표면 층이 양전하를 나타내는 것을 확인하였다. 실제 젖산 용액 배제율 확인 결과 고분자 전해질 그라프팅 층이 형성된 막에서 배제율이 크게 감소하는 것으로 보아 그라프팅 층에 의한 젖산 배제율 저감에 효과를 나타내었다.