• Title/Summary/Keyword: NS7

Search Result 498, Processing Time 0.028 seconds

Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order (100 ns급 대용량 자기펄스 압축시스템의 최적화)

  • 이용우;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.442-445
    • /
    • 2003
  • In this study, we developed the 40 J-class MPC(magnetic pulse compression) system for exciting excimer laser and investigated the optimal conditions of each stage of MPC circuit. This system consists of a DC power supply, a pulse transformer and four saturable inductors. The number of turns of saturable inductors at each stage of MPC circuit are 140, 25, 5, 1 and the optimal storage capacitance of each stage are 34 nF, 28.9 nF, 22.1 nF, respectively. In the improvement MPC system, we have obtained an output voltage of 43 kV, a current of 8.25 kA and a pulse duration of 360 ns. Also, the maximum pulse compression ratio of 77.7 and the current gain of 71.7 were obtained.

  • PDF

A Study on the Architectural Planning for Integrated Nursing Care Service in Ward of Public Hospital - Focused on the Regional Public Hospital in Korea - (간호·간병통합서비스를 위한 국내 공공병원 병동부에 대한 건축 계획적 연구 - 국내 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.121-129
    • /
    • 2017
  • The study is to identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing service has expanded nationwide from 2016 but 10 out of 34 public hospitals are currently unable to operate as nurses due to the shortage. Analyze each floor plan and space program of ward and provide the basic data for the construction of the architecture plans for Integrated nursing care service. For this study, selecting 14 wards of public hospital in Korea and then analyzes space organization, distance from NS to bedroom and NS to core(Elevator) and spatial hierarchy of them. Among the 14 public hospitals, there are 7 types of double-loaded corridor, 4 types of double corridor and 3 types of single corridor. If NS is placed centrally, the control of the outsider and the patient's control would be efficient, but most of NS are lean on one side of floor. the placement of NS should be independent of individual arrangements, but it should be smooth alignment with patient spaces, staff spaces, and public spaces. This study could serve as basic research for the architectural plan for future integrated nursing care in ward of public hospital.

Performance Evaluation of IEEE 802.16d ARQ Algorithm with NS-2 Simulator (NS-2를 이용한 IEEE 802.16d ARQ 알고리즘 성능분석)

  • Jang Jae-Shin;Kang Min-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7A
    • /
    • pp.666-673
    • /
    • 2006
  • In this paper, we evaluated the performance of 4 types of ARQ algorithms that have been adopted to offer reliable transmission between MAC layers. First of all, we implemented IEEE 802.16 ARQ algorithms with NS-2 network simulator and then evaluated the performances in various channel states. We used two performance measures to evaluate those performances. First, we used the total number of ARQ block in bytes that have been received without error. Second, we used ACK_Efficiency that is newly defined in this paper. From the results of simulation, we could be aware that each ARQ algorithm has different performance in a various channel states. For improving the transmission data rate in a specific channel state, we have to choose the right ACK interval as well as a suitable ARQ algorithm.

Inhibition of the Replication of Hepatitis C Virus Replicon with Nuclease-Resistant RNA Aptamers

  • Shin, Kyung-Sook;Lim, Jong-Hoon;Kim, Jung-Hye;Myung, Hee-Joon;Lee, Seong-Wook
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1634-1639
    • /
    • 2006
  • Hepatitis C virus (HCV)-encoded nonstructural protein 5B (NS5B) possesses RNA-dependent RNA polymerase activity, which is considered essential for viral proliferation. Thus, HCV NS5B is a good therapeutic target protein for the development of anti-HCV agents. In this study, we isolated two different kinds of nuclease-resistant RNA aptamers with 2'-fluoro pyrimidines against the HCV NS5B from a combinatorial RNA library with 40 nucleotide random sequences, using SELEX technology. The isolated RNA aptamers were observed to specifically and avidly bind the HCV NS5B with an apparent $K_d$ of 5 nM and 18 nM, respectively, in contrast with the original RNA library that hardly bound the target protein. Moreover, these aptamers could partially inhibit RNA synthesis of the HCV subgenomic replicon when transfected into Huh-7 hepatoma cell lines. These results suggest that the RNA aptamers selected in vitro could be useful not only as therapeutic agents of HCV infection but also as a powerful tool for the study of the HCV RNA-dependent RNA polymerase mechanism.

Implementation of TCP Retransmitted Packet Loss Recovery using ns-2 Simulator (ns-2 시뮬레이터를 이용한 TCP 재전송 손실 복구 알고리듬의 구현)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.741-746
    • /
    • 2012
  • Transmission control protocol(TCP) widely used as a transport protocol in the Internet includes a loss recovery function that detects and recovers packet losses by retransmissions. The loss recovery function consists of the two algorithms; fast retransmit and fast recovery. There have been researches to avoid nonnecessary retransmission timeouts (RTOs), which leads to selective acknowledgement (SACK) option and limited transmit scheme that are standardized by IETF (Internet Engineering Task Force). Recently, a method that covers the case in which a retransmitted packet is lost again has been propsed. The method, however, is not proved in terms of the additive increase multiplicative decrease (AIMD) principle of TCP congestion control. In this paper, therefore, we analyzed the method in terms of the principle by ns-simulations.

Circuit Design of Voltage Down Converter for High Speed Application (고속 스위칭 Voltage Down Converter 회로 설계에 대한 연구)

  • Lee, Seung-Wook;Kim, Myung-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.2
    • /
    • pp.38-49
    • /
    • 2001
  • This paper presents a new voltage down converter(VDC) using charge and discharge current adjustment circuitry that provides high frequency application. This VDC consist of a common driving circuit and compensation circuits: 2 sensors and each driving transistors for controlling gate current of driving transistor. These sensors are operated as adaptive biasing method with high speed and low power consumption. This circuit is designed with a $0.62{\mu}m$ N well CMOS technology. In H-spice simulation results, internal voltage is bounded ( IV, +0.6V) in proposed circuitry when load current rapidly increases and decreases during Gns between 0 and $200m{\Lambda}$. And the recovery time of internal voltage is about 7ns and 10ns when load current increases and decreases respectively. That is fast better than common driving circuit. Total power consumption is about 1.2mW.

  • PDF

A Study on the local thermal changes following herbal acupuncture on D.I.T.I.

  • Yook, Tae-Han
    • Journal of Pharmacopuncture
    • /
    • v.4 no.1
    • /
    • pp.103-104
    • /
    • 2001
  • This study was done to observe the effect on the local thermal changes of herbal acupuncture on D.I.T.I.. The objects of this study are as follows; If there are remarkable local thermal changes between pre and post herbal acupuncture therapy on D.I.T.I.or not. If there are those, We examine how long that changes are maintained, what the adequate interval is on herbal acupuncture therapy, and what the reaction in a .local or whole body are on that therapy Materials and Methods : To study the local thermal changes in herbal acupuncture therapy, D.I.T.I. was used. Determination of this analysis periods are pre and post-therapy(1 hour, 24hours, 48hours and 7days later). The study group was divided into three groups(comprised 23 students in oriental medical college, Woosuk University). One was NS(Normal Saline) group, another was CF(CARTHAMI SEMEN) group and the other was BU(FEL URSI + BENZOAR BOVIS) group. The Herbal Acupunture solution was injected 0.2ml divide into 0.05ml at tile P'ungmun(B12), P'yesu(B13), Pubun(B41), Paek'o(B42) 4 points. Then, in order to analyze the clinical form, we have observed response of 23 students whenever we checked the thermal changes of their after perfoming Results : The results were obtained as follows ; 1. There is no significant dermatothermal changes at NS group and CF group, but BU group have remarkable changes in 24, 48, 72 hours. 2. From post-therapy 1 hour to 48 hours, there is a significant change (P<0.01) at NS-BU group and CF-BU group, But there is none 7 days later. 3. In the analysis of whole or local body reaction, local pain appears at NS group(22%), CF group(11%), BU group(91%), discomfort reaction appears at CF group(14%), BU group(30%). BU groilp has feel vertigo(13%), drowsy (70%) and pain in action(52%). 4. In the analysis of the duration of physic진 reaction, BU group is most lately maintained. Conclusions : These results suggest that in the physical reaction of herbal acupuncture solutions, BU solution is more sensitive than CF solution or NS.

1V-2.7ns 32b self-timed parallel carry look-ahead adder with wave pipeline dclock control (웨이브 파이프라인 클럭 제어에 의한 1V-2.7ns 32비트 자체동기방식 병렬처리 덧셈기의 설계)

  • 임정식;조제영;손일헌
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.7
    • /
    • pp.37-45
    • /
    • 1998
  • A 32-b self-timed parallel carry look-ahead adder (PCLA) designed for 0.5.mum. single threshold low power CMOS technology is demonstrated to operate with 2.7nsec delay at 8mW under 1V power supply. Compared to static PCLA and DPL adder, the self-timed PCLA designed with NORA logic provides the best performance at the power consumption comparable to other adder structures. The wave pipelined clock control play a crucial role in achieving the low power, high performance of this adder by eliminating the unnecessary power consumption due to the short-circuit current during the precharge phase. Th enoise margin has been improved by adopting the physical design of staic CMOS logic structure with controlled transistor sizes.

  • PDF

Study on the Electro-Optic Characteristics Depending on UV Condition in the Normally Scattering(NS)/Normally Transparent(NT) Polymer Dispersed Liquid Crystal Mode (Normally Scattering(NS)/Normally Transparent (NT) 고분자 분산형 액정 모드에서 UV 조건에 따른 전기 광학특성 연구)

  • Kim, M.S.;Seo, Y.H.;Lee, M.H.;Rhee, J.M.;Lee, T.S.;Lee, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1050-1053
    • /
    • 2003
  • Polymer dispersed liquid crystal mode can be classified into two cases, normally scattering mode (NS) and normally transparent (NT) mode according to an initial state. Electro-optic characteristic NS/NT PDLC mode can be improved by controlling the factors to influence the phase separation. In case of NS PDLC mode, we inspected change of a phase separation as a function of curing temperature for the mixture of E7 and NOA65 with different ratios. When the LC concentration is less than polymer such as LC : NOA65 = 40 : 60wt%, the PDLC cell is influenced strongly by the curing temperature. However, when LC concentration is much less than polymer such as LC : NOA65 : 80 : 20wt%, it is influenced slightly by the curing temperature. In case of NT PDLC mode, we observed change of a phase separation as a function of the ratio of the mixture and UV conditions such as curing temperature, UV intensity The cell made with strong UV intensity and curing temperature of $20^{\circ}C$, in case that the ratio of LC to polymer is 70:30wt%, showed good electro-optic characteristics.

  • PDF

The Effect of Cutting Positions and Temperature on the Rooting of Bitter Gourd (여주 삽목 시 삽수절단 위치와 온도조건이 발근에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Choi, Chang Sun;Kim, Sang Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.162-167
    • /
    • 2016
  • This study was carried out to investigate proper stem cutting position and air temperature to regenerate roots from cuttings of bitter gourd. 'NS454' (NS) and 'Dragon' (DR) cultivars were tested and the cutting position was cut at the 3rd node in the stem (treatment I) and cut at the central part (stem segment) between 3rd leaf and 4th leaf in the stem (treatment II). The air temperature was maintained at 18, 23, 28 and $35^{\circ}C$ in the growth chambers, respectively. The photosynthetic photon flux at the ground of a chamber was maintained in approximately $150-200{\mu}mol\;m^{-2}s^{-1}$ during the 16-hour photoperiod. The relative humidity in the chambers was maintained over 85%. After 10 days of cuttings, regardless of cutting position, DR and NS cultivars showed 100% the survival rate in the $18^{\circ}C$ or $23^{\circ}C$ treatments, however, most of plants $18^{\circ}C$ treatment had not rooting. In the $28^{\circ}C$ treatment, regardless of cutting position, DR and NS cultivars showed 100% of the rooting rate. In the $23^{\circ}C$ treatment, for DR cultivar, the node cutting showed 90% of rooting rate and the stem segment cutting showed 40% rooting rate. For NS cultivar, the node cutting showed 50% of rooting rate and the stem segment cutting showed 40% rooting rate. DR and NS cultivars have high rooting rate, while the rooting rate remarkably decreased in the $35^{\circ}C$ treatment. For DR cultivar, the stem segment cutting showed 5.3 of the highest rooting number and the node cutting showed 2.7 rooting number in the $28^{\circ}C$ treatment. NS cultivar was not significantly different the rooting regardless of cutting position. The results suggested that cutting at the stem segment cutting of bitter gourd is an effective cutting method for increasing survival rate and the air temperature should be maintained at $28^{\circ}C$.