• Title/Summary/Keyword: NPP concrete

Search Result 53, Processing Time 0.025 seconds

Development of Aging Management System for the Concrete Structure (원전 콘크리트 구조물의 열화관리시스템 개발)

  • 조명석;방기성;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.546-550
    • /
    • 1996
  • The personal-computer software program named SAMS(Structural Aging Management System) was developed for the concrete structure of NPP(Nuclear Power Plant). SAMS is constituted of three part, detabase system containing various inspection data, operation program for standard input/output of the inspection data, and application program for efficient operation of database system. Using the SAMS, the field engineers can easily acquire the information about the various inspection data, repair and accidental histories of NPP structures. SAMS will contribute to the effcient maintenance of NPP structures.

  • PDF

Investigation on damage development of AP1000 nuclear power plant in strong ground motions with numerical simulation

  • Chen, Wanruo;Zhang, Yongshan;Wang, Dayang;Wu, Chengqing
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1669-1680
    • /
    • 2019
  • Seismic safety is considered to be one of the key design objectives of AP1000 nuclear power plant (NPP) in strong earthquakes. Dynamic behavior, damage development and aggravation effect are studied in this study for the three main components of AP1000 NPP, namely reinforced concrete shield building (RCSB), steel vessel containment (SVC) and reinforced concrete auxiliary building (RCAB). Characteristics including nonlinear concrete tension and compressive constitutions with plastic damage are employed to establish the numerical model, which is further validated by existing studies. The author investigates three earthquakes and eight input levels with the maximum magnitude of 2.4 g and the results show that the concrete material of both RCSB and RCAB have suffered serious damage in intense earthquakes. Considering RCAB in the whole NPP, significant damage aggravation effect can be detected, which is mainly concentrated at the upper intersection between RCSB and RCAB. SVC and reinforcing bar demonstrate excellent seismic performance with no obvious damage.

Long-Term Performance of Safety Related Concrete Structures in Nuclear Power Plants (원전 콘크리트 구조물의 장기내구성능 평가)

  • Yoon, Eui-Sik;Paek, Yong-Lak;Lim, Jae-Ho;Chung, Yun-Suk;Choi, Kang-Ryong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.237-240
    • /
    • 2006
  • Almost 30 years have been passed since the first nuclear power plant was operated in Korea. Many studies have been actively conducted from the early 1990's in order to develop the deterioration management system for concrete structures in NPPs(Nuclear Power Plants) accordingly. Base on these studies, a systematic deterioration management program has developed and operated since 1997. According to this program, systematic inspections to provide database and evaluation were periodically performed (every overhaul at intervals of $12{\sim}18$ month and every five years). Accumulated deterioration database was usefully utilized for the NPP PSR (Periodic Safety Review). In this paper, the long-term durability and integrity of Kori 1,2 NPP concrete structures which are the oldest ones in Korea were evaluated based on the precise inspection database and regulatory inspection results including compressive strength, depth of carbonation, amount of chlorination and spontaneous potential of reinforcing bar, etc. It was noted that Kori 1,2 NPP structures have not any serious durability problems.

  • PDF

ASSESSMENT OF PROPERTIES AND DURABILITY OF FLY ASH CONCRETE USED IN KOREAN NUCLEAR POWER PLANTS

  • Cho, Myung-Sug;Noh, Jae-Myoung
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.331-342
    • /
    • 2012
  • Since the opening of the Shin-Kori #1,2 in 2005, fly ash mixed concrete has been used for NPP concrete structures under construction in Korea with the aim of preventing aging and improving durability. In this paper, the quality suitability of fly ash manufactured in Korea is assessed and the basic physical properties of fly ash mixed concrete and its durability against primary causes of aging are verified through experimental methods. Because of the internal structure filling effect from the pozzolanic reaction of fly ash and the resulting improvements in mechanical performance in such areas as strength and salt damage resistance, the durability of fly ash mixed concrete is shown to be superior. It is judged that this result can be applied in measures not only for improving the safety of NPP structures in operation in Korea but also for implementing effective structure life management should extending the life of structures be needed in the future.

Effective Thermal Conductivity and Diffusivity of Containment Wall for Nuclear Power Plant OPR1000

  • Noh, Hyung Gyun;Lee, Jong Hwi;Kang, Hie Chan;Park, Hyun Sun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.459-465
    • /
    • 2017
  • The goal of this study is to evaluate the effective thermal conductivity and diffusivity of containment walls as heat sinks or passive cooling systems during nuclear power plant (NPP) accidents. Containment walls consist of steel reinforced concrete, steel liners, and tendons, and provide the main thermal resistance of the heat sinks, which varies with the volume fraction and geometric alignment of the rebar and tendons, as well as the temperature and chemical composition. The target geometry for the containment walls of this work is the standard Korean NPP OPR1000. Sample tests and numerical simulations are conducted to verify the correlations for models with different densities of concrete, volume fractions, and alignments of steel. Estimation of the effective thermal conductivity and diffusivity of the containment wall models is proposed. The Maxwell model and modified Rayleigh volume fraction model employed in the present work predict the experiment and finite volume method (FVM) results well. The effective thermal conductivity and diffusivity of the containment walls are summarized as functions of density, temperature, and the volume fraction of steel for the analysis of the NPP accidents.

Evaluation on Sulfate Attack for Concrete Structures of Nuclear Power Plants (원자력발전소 콘크리트 구조물의 황산염 침식 평가)

  • Lee, Jong-Suk;Moon, Han-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.169-176
    • /
    • 2004
  • The Mechanistic model, considering expansion stress, coefficient of diffusion etc. to time, is applied to predict the deterioration of concrete structures of the nuclear power plant(NPP) due to sulfate attack. Mix design for the test was three kinds of specified compressive strength 385, 280 and $210kgf/cm^2$ which are used to construct NPPs and cement was type I and V. The immersion test was performed with 10% $Na_2SO_4$ solution to cement type and strength for a year. The coefficient of diffusion on each concrete mix is calculated based on the results of immersion test, and it is used for predicting the sulfate attack of the concrete structures of NPP. The coefficient of diffusion of the target concrete ranged $0.5763{\sim}3.9002{\times}10^{-12}m^2/sec.$, and the sulfate attack rate of concrete structures of the NPP was predicted as 0.1~7.1 mm/year.

Evaluation for Mechanical Properties of Compress Strength and Dry Density of Concrete at NPP (원전 시설용 콘크리트의 압축강도 및 건조밀도 특성 평가)

  • Lee, Young-Dae;Kim, Gyu-Yong;Shin, Kyoung-Su;Nam, Jeong-Soo;Lee, Tae-Gyu;Choe, Gyeong-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.53-54
    • /
    • 2011
  • The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=1.0913X-0.2458) and developed a correlation expression considering standard deviation of bulk dry density (y=1.0913X-0.3358).

  • PDF

Structural safety reliability of concrete buildings of HTR-PM in accidental double-ended break of hot gas ducts

  • Guo, Quanquan;Wang, Shaoxu;Chen, Shenggang;Sun, Yunlong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1051-1065
    • /
    • 2020
  • Safety analysis of nuclear power plant (NPP) especially in accident conditions is a basic and necessary issue for applications and commercialization of reactors. Many previous researches and development works have been conducted. However, most achievements focused on the safety reliability of primary pressure system vessels. Few literatures studied the structural safety of huge concrete structures surrounding primary pressure system, especially for the fourth generation NPP which allows existing of through cracks. In this paper, structural safety reliability of concrete structures of HTR-PM in accidental double-ended break of hot gas ducts was studied by Exceedance Probability Method. It was calculated by Monte Carlo approaches applying numerical simulations by Abaqus. Damage parameters were proposed and used to define the property of concrete, which can perfectly describe the crack state of concrete structures. Calculation results indicated that functional failure determined by deterministic safety analysis was decided by the crack resistance capability of containment buildings, whereas the bearing capacity of concrete structures possess a high safety margin. The failure probability of concrete structures during an accident of double-ended break of hot gas ducts will be 31.18%. Adding the consideration the contingency occurrence probability of the accident, probability of functional failure is sufficiently low.