• Title/Summary/Keyword: NOTCH4

Search Result 450, Processing Time 0.035 seconds

Effects of Mandibular Midline Shift and Difference of Mandibular Height on the Masticatory Muscle Activity (하악 정중선의 편위와 하악골의 높이차가 저작근 활성에 미치는 영향)

  • Jung, Dae-Yeon;Han, Kyung-Soo;Hyun, Tae-Yeon;Kwag, Dong-Kon
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.1
    • /
    • pp.75-85
    • /
    • 2001
  • This study was performed to investigate the effect of mandibular midline shift and difference of mandibular height between both sides on the electromyo- graphic(EMG) activity of the masticatory muscles on clenching or gum chewing movement. For this study, 105 patients with temporomandibular disorders(TMD) were selected and panoramic radiograph were taken. Amount and side of the midline shift and height of the mandible from antegonial notch to the top of the condylar head were measured on panoramic view. $BioEMG^{(R)}$ (Bioresearch Inc., Milwaukee, USA) was used for recording of EMG activity(${\mu}V$) of the anterior temporalis and the superficial masseter on clenching or gum chewing movement. EMG activity on clenching during 533msec period were measured for activity of the starting point and the one second-after activity as the early EMG and the maximum EMG, respectively. EMG activity on gum chewing movement were measured for activity of the first and the second chewing stroke. The data collected were analysed by SPSS windows program, and the results of this study were as follows : 1. Height of the mandible was 8.06cm on right side and 8.03cm on left side, and showed no difference by age, but significantly differed by sex with higher in male subjects. 2. Mean value of the midline shift was 0.1mm with range of 0~5mm on both sides. The amount and side of the midline shift did not related with height difference of the mandible and/or the EMG activity of the masticatory muscles on clenching. 3. Prevalence of higher right side and higher left side of the mandible were almost same, and the EMG activity of higher side was not higher than that of the other side. 4. In the subjects with height difference of more than 5mm between both sides of the mandible, the early EMG activity on clenching were differed for the anterior temporalis, but the maximum activity were differed for the superficial masseter. 5. In the subjects with height difference of more than 5mm between both sides of the mandible, EMG activity of the anterior temporalis of the gum chewing side was not higher than that of the other side when chewing on the side of lower height, but in the subjects with height difference of less than 5mm, the EMG activity was higher than that of the other side.

  • PDF

Preservation and Utilitization of Uninhabited Islets in Busan Metropolitan City (부산광역시 해안 무인도서의 보전(保全)과 활용)

  • Kim, Hang-Muk;Yu, Je-U
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.475-486
    • /
    • 2009
  • The geological survey of the Mokdo island is for the fist time conduted in Korea history. The island had erupted before $70{\sim}80$ million years as a strato-volcano. The original volcano had been dissected for long periods up to the skeletal stage through the planeze stage. If the island area is surveyed afterwrds in detail, the position of crater is available to be found, either. The coastal terrace is found at 50m level in Mokdo island which is correlated to its fourth plane. The microgeomorphological features as coastal terrace, cliff, sea cave, wave-cut bench, sea stacks, notch, and tafoni, etc. were described. The Mogdo island is located off Molundae at the extension of Nagdong Jeongmaeg(낙동정맥 洛東正脈) showing a "floating turtle". The name of Mogdo island is needed to change to the "Yoo-goo-do" which means the swimming turtle. The Mokdo island is as suitable tourist attraction for if has enough touism sesouccesein sea. The deuelopsment of coartal sightseeing anound lighthoure and uninhabited islands will hare an impontant effect upon construction of the oceanic capitol city of Busan Haabor. The master plan built up an arboretum on the island, a coastal oceanarium, a seaweeds garden under sea coast, and other oceanic culture-spaces is completed in the study.

  • PDF

Genetic diversity and selection of Tibetan sheep breeds revealed by whole-genome resequencing

  • Dehong Tian;Buying Han;Xue Li;Dehui Liu;Baicheng Zhou;Chunchuan Zhao;Nan Zhang;Lei Wang;Quanbang Pei;Kai Zhao
    • Animal Bioscience
    • /
    • v.36 no.7
    • /
    • pp.991-1002
    • /
    • 2023
  • Objective: This study aimed to elucidate the underlying gene regions responsible for productive, phenotypic or adaptive traits in different ecological types of Tibetan sheep and the discovery of important genes encoding valuable traits. Methods: We used whole-genome resequencing to explore the genetic relationships, phylogenetic tree, and population genetic structure analysis. In addition, we identified 28 representative Tibetan sheep single-nucleotide polymorphisms (SNPs) and genomic selective sweep regions with different traits in Tibetan sheep by fixation index (Fst) and the nucleotide diversity (θπ) ratio. Results: The genetic relationships analysis showed that each breed partitioned into its own clades and had close genetic relationships. We also identified many potential breed-specific selective sweep regions, including genes associated with hypoxic adaptability (MTOR, TRHDE, PDK1, PTPN9, TMTC2, SOX9, EPAS1, PDGFD, SOCS3, TGFBR3), coat color (MITF, MC1R, ERCC2, TCF25, ITCH, TYR, RALY, KIT), wool traits (COL4A2, ERC2, NOTCH2, ROCK1, FGF5, SOX9), and horn phenotypes (RXFP2). In particular, a horn-related gene, RXFP2, showed the four most significantly associated SNP loci (g. 29481646 A>G, g. 29469024 T>C, g. 29462010 C>T, g. 29461968 C>T) and haplotypes. Conclusion: This finding demonstrates the potential for genetic markers in future molecular breeding programs to improve selection for horn phenotypes. The results will facilitate the understanding of the genetic basis of production and adaptive unique traits in Chinese indigenous Tibetan sheep taxa and offer a reference for the molecular breeding of Tibetan sheep.

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

Purification Efficiency of Slop & Plane Water Treatment Part of SRT System Using Eco-Concrete (Eco-Concrete를 이용한 SRT System의 사면수처리부와 평면수처리부의 정화효율분석)

  • Jang, Won-Geun;Park, Jae-Young;Choi, I-Song;Chang, Jun-Young;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1860-1864
    • /
    • 2006
  • 본 연구는 강우시 발생되는 강우유출수와 합류식하수관거월류수에 의해 하천으로 유입되는 오염부하를 저감시키기 위한 공법으로, 고수부지 및 제방사면부와 둔치부를 형상화하여 pilot를 제작하였고, 연속적으로 시운전을 한 SRTS(Stormwater Runoff Treatment System)에 관한 것이다. SRT system 내부의 사면수처리부와 평면수처리부에는 다공성 콘크리트를 충진하였다. system 상부에는 식생을 조성하여 뿌리가 수면에 닿아 영양물질을 흡수하는 목적으로 사면수처리부와 평면수처리부에 각각 정육각형과 직사각형인 식생포트를 탈.부착이 가능하도록 고안하였다. 내부에서는 토양과 수처리조 사이에 연결관을 부착하였고, 모세관현상에 의해 토양이 수분을 흡수하도록 구성하였다. pilot plant는 유입부, 사면 수처리부, 평면 수처리부, 유출부로 나누었다. 유입부는 유입펌프와 V-notch로 구성하였고, 유입펌프는 2대를 설치하여 1시간 간격으로 연속적 유입으로 유량조절이 가능하도록 상호교대 운전을 하였다. 평면 수처리부$(W(1.0m){\times}(L(2.4m){\times}H(0.6m))$는 장방형의 접촉산화조로서 하부에 슬러지 침전 및 저류를 위한 hopper를 설치하여 슬러지의 원활한 수집 및 인발이 가능하도록 하였다. 유출부는 사각weir를 설치하였다. 강우유출수의 pH는 $7.27{\sim}7.92$이고, DO농도는 $7.12{\sim}7.88mg/l$로 관측되었다. 2차처리수의 pH는 평균7.4이고 DO농도는 최저 4.5 mg/l에서 최고 8.9 mg/l로 평균 6.8 mg/l로 관측되었다. 또한 강우유출수의 유입수의 T-N, T-P 농도는 각각 $17.5{\sim}22.5mg/l,\;8.9{\sim}11.4mg/l$의 범위이고, 2차 처리수의 유입수의 T-N, T-P 농도와 유사하였다.적인 방법론을 제시할 수 있을 것으로 사료된다.첨두홍수량을 저류하기 위해서 상대적으로 넓은 저류면적이 필요한 것으로 나타난다. 대등한 수위감소값의 홍수저감효과를 발휘하기 위해서 본 연구에서는 On-Line 저류지 면적은 Off-Line 저류지에 비 두배 이상이 필요한 것으로 보여졌다.들에 관한 정보는 종종 현장관측에서 조차 무시되는 경우가 많다. 이에 본 연구에서는 수질모형의 매개변수 중 특히 수리특성에 관련된 매개변수들이 수질에 미치는 영향을 파악하는 것을 목적으로 하고 있다. 이를 위해 적용된 수질모형은 QualKo를 사용하였으며, 대상 하천은 낙동강 본류 경남구간 시점 부근인 회천 합류 전부터 낙동강 본류 경남구간 종점 부근인 밀양강 합류 전까지의 경남 오염총량관리 기본계획 시 구축된 모형 매개변수를 바탕으로 분석을 수행하였다. 일차오차분석을 이용하여 수리매개변수와 수질매개변수의 수질항목별 상대적 기여도를 파악해 본 결과, 수리매개변수는 DO, BOD, 유기질소, 유기인 모든 항목에 일정 정도의 상대적 기여도를 가지고 있는 것을 알 수 있었다. 이로부터 수질 모형의 적용 시 수리 매개변수 또한 수질 매개변수의 추정 시와 같이 보다 세심한 주의를 기울여 추정할 필요가 있을 것으로 판단된다.변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하

  • PDF

The relationship between condyle position, morphology and chin deviation in skeletal Class III patients with facial asymmetry using cone-beam CT (안면비대칭을 동반한 골격성 III급 부정교합자에서 하악 과두의, 위치 형태와 이부 편위의 관계: cone-beam CT를 이용한 연구)

  • Lee, Bo-Ram;Kang, Dae-Keun;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.87-97
    • /
    • 2011
  • Objective: Facial asymmetry is usually evaluated from the difference in length and angulation of the maxilla and mandible. However, asymmetric position or shape of the condyle can also affect the expression of asymmetry. The purpose of this study was to evaluate the correlation between condylar asymmetry and chin point deviation in facial asymmetry. Methods: Cone-beam CT images of fifty adult skeletal Class III patients were studied. Thirty patients who had more than 4 mm menton deviation were categorized in the asymmetric group. Twenty patients with less than 4 mm menton deviation were assigned to the symmetric group. Anteroposterior and transverse condyle positions were evaluated from the cranial base. The greatest mediolateral diameter (GMD) of the condyle in the axial plane and angulation to the coronal plane were measured. The height and volume of the condyles were evaluated. Results: The symmetric group had no statistical difference between both condyles in position, angulation, GMD, height and volume. In the asymmetric group, the non-deviated side condyle was larger in GMD, height and volume than the deviated side. There was no statistical difference in condyle position and angulation. The GMD, height difference and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. From the linear regression analysis, condylar volume ratio was a significant factor affecting chin deviation. Conclusions: These findings suggests that the non-deviated side condyle is larger than the deviated side. In addition, condylar asymmetry can affect the expression of facial asymmetry.

Cosmetic Results of Conservative Treatment for Early Breast Cancer (조기유방암에서 유방보존수술 및 방사선치료후의 미용적 결과)

  • Kim Bo Kyoung;Shin Seong Soo;Kim Seong Deok;Ha Sung Whan;Noh Dong-Young
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.21-26
    • /
    • 2001
  • Purpose : This study was peformed to evaluate the cosmetic outcome of conservative treatment for early breast cancer and to analyze the factors influencing cosmetic outcome. Materials and Methods : From February 1992 through January 1997, 120 patients with early breast cancer were treated with conservative surgery and postoperative radiotherapy. The types of conservative surgery were quadrantectomy and axillary node dissection for 108 patients $(90\%)$ and lumpectomy or excisional biopsy for 10 patients $(8.3\%)$. Forty six patients $(38\%)$ received adjuvant chemotherapy (CMF or CAF). Cosmetic result evaluation was carried out between 16 and 74 months (median, 33 months) after surgery. The cosmetic results were classified into four categories, i.e., excellent, good, fair, and poor. The appearances of the patients' breasts were also analyzed for symmetry using the differences in distances from the sternal notch to right and left nipples. A logistic regression analysis was performed to identify independent variables influencing the cosmetic outcome. Results : Cosmetic score was excellent or good in $76\%$ (91/120), fair in $19\%$ (23/120) and poor in $5\%$ (6/120) of the patients. Univariate analysis showed that tumor size (T1 versus T2) (p=0.04), axillary node status (N0 versus N1) (p=0.0002), extent of surgery (quadrantectomy versus lumpectomy or excisional biopsy) (p=0.02), axillary node irradiation (p=0.0005) and chemotherapy (p=0.0001) affected cosmetic score. Multivariate analysis revealed that extent of surgery (p=0.04) and chemotherapy (p=0.0002) were significant factors. For breast symmetry, univariate analysis confirmed exactly the same factors as above. Multivariate analysis revealed that tumor size (p=0.003) and lymph node status (p=0.007) affected breast symmetry. Conclusion : Conservative surgery and postoperative radiotherapy resulted in excellent or good cosmetic outcome in a large portion of the patients. Better cosmetic results were achieved generally in the group of patients with smaller tumor size, without axillary node metastasis and treated with less extensive surgery without chemotherapy.

  • PDF

Femoral Tunnel Obliquity between the Transtibial and Anteromedial Portal Technique in Single Bundle Anterior Cruciate Ligament Reconstruction (전방십자인대 단일 다발 재건술에서 경경골 술기 및 전내측 삽입구를 이용한 대퇴골 터널의 기울기)

  • Lee, Ju-Hong;Park, Jong-Hyuk;Bae, Hyeon-Kyeong;Kim, Jong-Gil;Wang, Sung-Il
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose: To compare the obliquity of femoral tunnels prepared with transtibial (TT) versus anteromedial portal technique (AM) using x-ray in single-bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: Among one-hundred thirty two patients who were undergoing ACL reconstruction from January 2007 to December 2009, thirty patients using TT and twenty patients using AM, those who had single-bundle ACL reconstruction, were evaluated with plain radiographs including anteroposterior, intercondylar notch and lateral view to compare the obliquity of bone tunnels. Results: The mean coronal obliquity of femoral tunnel for TT was $71^{\circ}$ (range; $65^{\circ}{\sim}77^{\circ}$), while for AM was $51^{\circ}$ (range; $39^{\circ}{\sim}60^{\circ}$) and the mean sagittal obliquity of femoral tunnel for TT was $22.7^{\circ}{\pm}7.8$, while for AM was $30.2^{\circ}{\pm}6.9$, their differences between them were statistically significant (P<0.05). However, there were no differences between two techniques on the tibial tunnel obliquity in coronal and sagittal plane. Conclusion: Anterior cruciate ligament reconstruction using AM portal technique allows more horizontally oriented and divergent femoral tunnel compared to that of transtibial technique. This seems to enable the graft placement into the femoral footprint and preserve the posterior cortical wall.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).