• Title/Summary/Keyword: NO emission index

Search Result 65, Processing Time 0.02 seconds

Changes in Profitability of a Double Cropping using the Carbon Fixation Method (탄소고정방식을 활용한 농작물 이모작의 수익성 변화)

  • Mo, Tae-Jun;Kim, Brian H.S.
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.2
    • /
    • pp.61-70
    • /
    • 2020
  • The purpose of this study is to calculate the annual carbon reduction of crops according to the carbon fixation method of agricultural land, therefore to analyze whether the economic inducement of farmers to switch from single cropping to double cropping if the amount of carbon reduction were traded on the Korea Exchange. The analysis targets were Gyeonggi Province, which was divided into four areas to compare the difference between agricultural income and carbon income by crop and cropping system. Agricultural profit was estimated by multiplying the prior data of 2012 by the change rate of the consumer price index, and carbon income was calculated through the carbon reduction for each crop and the average transaction price of KAU19 traded on the Korea Exchange. According to the analysis, the profit rate of double cropping in all areas is -110.4% to 23% compared to single cropping, when only agricultural profit is taken into account, with no economic inducement for farmers to change the cropping system. However, when carbon income is taken into account together, the profit rate of double cropping rises significantly from 122.5% to 238.9% over a single operation in all areas, resulting in an economic inducement to switch the cropping system. This research is meaningful in that farming households could raise their income by additional carbon income, and that carbon credits could be supplied at Korea Exchange to further boost the carbon emission exchange.

TWO-COLOR VR CCD PHOTOMETRY OF OLD NOVA V603 AQUILAE

  • Andronov Ivan L.;Ostrova Nataliya I.;Kim, Yong-Gi;Burwitz V.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.211-222
    • /
    • 2005
  • Results of 6 nights of CCD VR photometry of the nova-like variable V603 Aquilae (Nova Aquilae 1918) obtained at the Mallorcian 35-cm telescope in July 2004 are reported. The ephemeris for the superhump maximum is Max.HJD=2453213.60546(96)+0.14813(10)E. The waves with $3.^d9,\;1.^d4,\;0.^d135$ are statistically significant, which may be interpreted as the negative superhump-orbital, the beat periods (negative superhump- positive superhump) and the negative superhump with low amplitude, respectively. Another possible time-scale is $0.^d8,$ which has no coincidence with the beat periods. Quasi-periodic oscillations with an effective period of 18 minutes have been detected, which are close to 15.6 minutes reported by some authors. Their effective semi-amplitudes are $^m.045\;and\;0^m.051$ for V and R, respectively. This corresponds to the 0.12 mag excess in the color index V-R as compared with the mean color, which can be understood as the pulsed emission in the hotter inner parts of the accretion disk, similar to that observed in TT Ari and MV Lyr.

The Influence of CH3Cl on CH4/CH3Cl/O2/N2 Premixed Flames Under the O2 Enrichment (산소부화 조건인 CH4/CH3Cl/O2/N2 예혼합 화염에서 CH3Cl의 영향)

  • Shin Sung Su;Lee Ki Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.255-262
    • /
    • 2005
  • A comprehensive experimental and numerical study has been conducted to understand the influence of $CH_{3}Cl$ addition on $CH_4/O_2/N_2$ premixed flames under the oxygen enrichment. The laminar flame speeds of $CH_4/CH_{3}Cl/O_2/N_2$ premixed flames at room temperature and atmospheric pressure are experimentally measured using Bunsen nozzle flame technique, varying the amount of $CH_{3}Cl$ in the fuel, the equivalence ratio of the unburned mixture, and the level of the oxygen enrichment. The flame speeds predicted by a detailed chemical kinetic mechanism employed are found to be in excellent agreement with those deduced from experiments. Even though the molar amount of $CH_{3}Cl$ in a methane flame is increased, temperature at the postflame is not significantly varied, but the calculated heat release rate and emission index of NO are largely decreased for the oxygen enhanced flame. The function of $CH_{3}Cl$ as inhibitor on hydrocarbon flames becomes weakened as the level of the oxygen enrichment is increased from 0.21 to 0.5.

Eclipse Spectrum of Her X-1 Observed by ASCA in the Low Intensity State

  • Choi, C.S.;Seon, K.I.
    • Bulletin of the Korean Space Science Society
    • /
    • 1995.10a
    • /
    • pp.30-30
    • /
    • 1995
  • We present the results of analysis on the X-ray observations of the binary X-ray pulsar Her X-I. made with ASCA/SIS on August 13-14. 1993. An eclipse transition from ingress to egress was fully covered by the observations. The main findings are as follows; (1) a model of power-law plus black-body is required to interpret the entire eclipse spectrum. and the black-body component appears at < 0.7 keV. (2) the power-law continuum which has photon index ${\alpha}\;=\;{0.84^{\;+0.14}}_{\;-0.19}$ is very similar to that of detected by Ginga/LAC (${\alpha}\;=\;0.80\;{\pm}\;0.04$), (3) the calculated eclipse flux of $2^{-10}\;keV.{\;}~{\;}1.8{\pm}10^{-11}{\;}ergs{\;}cm^{-2}s^{-1}$, is consistent with the Ginga observation carried out in the high intensity state ~2.0{\pm}10^{-11}{\;}ergs{\;}cm^{-2}s^{-1}$, (4) there is no significant absorption feature. and an upper limit of the aborption column $NH{\;}\leq{\;}3{\pm}10^{20}\;cm^{-2}$ is determined at the 90% confidence limit. Based on these results, we suggest that extended matter surrounding the binary system should be existed persistently with stable conditions, and scattering of the source continuum by the matter is responsible for the eclipse emission.ission.

  • PDF

Design of Asymmetric Pre-swirl Stator for KVLCC2 Considering Angle of Attack in Non-uniform Flow Fields of the Stern (선미의 불균일 유동장에서 받음각을 고려한 비대칭 전류고정날개 설계)

  • Lee, Ki-Seung;Kim, Moon-Chan;Shin, Yong-Jin;Kang, Jin-Gu
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.352-360
    • /
    • 2019
  • International Maritime Organization (IMO) regulates an emission of greenhouse gases by creating an Energy Efficiency Design Index (EEDI) to reduce environmental pollution. In propulsion system field, studies are under way on Energy Saving Device (ESD), which can improve propulsion efficiency with the propeller, to reduce the EEDI. Among the studies, the study of Pre-Swirl Stator (PSS) has been actively conducted from long time ago. Recently the variable pith angle type pre-swirl stator has been studied to improve the propulsion efficiency in non-uniform flow fields of the Stern. However, for traditional design methods, no specific design method has been established on the blade or location of radius. In this study, proper design method is proposed for each blade or location for radius according to hydrodynamic pitch angle.

Value of Bone Scintigraphy and Single Photon Emission Computed Tomography (SPECT) in Lumbar Facet Disease and Prediction of Short-term Outcome of Ultrasound Guided Medial Branch Block with Bone SPECT

  • Koh, Won-Uk;Kim, Sung-Hoon;Hwang, Bo-Young;Choi, Woo-Jong;Song, Jun-Gul;Suh, Jeong-Hun;Leem, Jeong-Gill;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2011
  • Background: Facet joint disease plays a major role in axial low-back pain. Few diagnostic tests and imaging methods for identifying this condition exist. Single photon emission computed tomography (SPECT) is reported that it has a high sensitivity and specificity in diagnosing facet disease. We prospectively evaluated the use of bone scintigraphy with SPECT for the identification of patients with low back pain who would benefit from medial branch block. Methods: SPECT was performed on 33 patients clinically suspected of facet joint disease. After SPECT, an ultrasound guided medial branch block was performed on all patients. On 28 SPECT-positive patients, medial branch block was performed based on the SPECT findings. On 5 negative patients, medial branch block was performed based on clinical findings. For one month, we evaluated the patients using the visual analogue scale (VAS) and Oswestry disability index. SigmaStat and paired t-tests were used to analyze patient data and compare results. Results: Of the 33 patients, the ones who showed more than 50% reduction in VAS score were assigned 'responders'. SPECT positive patients showed a better response to medial branch blocks than negative patients, but no changes in the Oswestry disability index were seen. Conclusions: SPECT is a sensitive tool for the identification of facet joint disease and predicting the response to medial branch block.

Luminescence Characteristics of Blue Phosphor and Fabrication of a UV-based White LED (UV 기반 백색 LED용 청색 형광체의 발광특성 및 백색 LED 제조)

  • Jung, Hyungsik;Park, Seongwoo;Kim, Taehoon;Kim, Jongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.4
    • /
    • pp.216-220
    • /
    • 2014
  • We have synthesized a $CaMgSi_2O_6:Eu^{2+}$ blue phosphor via a solid-state reaction method. The $CaMgSi_2O_6:Eu^{2+}$ phosphor has monoclinic structure with a space group of C2/c (15), and an emission band peaking at 450 nm (blue) due to the $4f^7-4f^65d$ transition of the $Eu^{2+}ion$. The emission intensity at $100^{\circ}C$ is 54% of the value at room temperature. A white LED was fabricated by integrating a UV LED (400 nm) with our blue phosphor plus two commercial green and red phosphors. The white LED shows a color temperature of 3500 K with a color rendering index of 87 (x = 0.3936, y = 0.3605), and a luminous efficiency of 18 lm/W. The white LED shows a luminance maintenance of 97% after operation at 350 mA for 400 hours at $85^{\circ}C$.

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF

Influences of Environmental Conditions and Refractory Organic Matters on Organic Carbon Oxidation Rates Measured by a High Temperature Combustion and a UV-sulfate Methods (다양한 환경요인과 난분해성 유기물에 따른 고온산화 및 UV산화방식 총 유기탄소 산화율 변화)

  • Jung, Heon-Jae;Lee, Bo-Mi;Lee, Keun-Heon;Shin, Hyun-Sang;Hur, Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.98-107
    • /
    • 2016
  • This study examined the effects of environmental conditions and the presence of refractory organic matter on oxidation rates of total organic carbon (TOC) measurements based on high temperature combustion and ultraviolet-sulfate methods. Spectroscopic indices for prediction of oxidation rates were also explored using the UV spectra and fluorescence excitation-emission matrix (EEM) of humic acids. Furthermore, optimum TOC instrument conditions were suggested by comparing oxidation rates of a standard TOC material under various conditions. Environmental conditions included salts, reduced ions, and suspended solids. Salts had the greatest influence on oxidation rates in the UV-sulfate method. However, no effect was detected in the high temperature combustion method. The UV-sulfate method showed lower humic substance oxidation rates, refractory natural organic matter, compared to the other methods. TOC oxidation rates for the UV-sulfate method were negatively correlated with higher specific-UV absorbance, humification index, and humic-like EEM peak intensities, suggesting that these spectroscopic indices could be used to predict TOC oxidation rates. TOC signals from instruments using the UV-sulfate method increased with increasing chamber temperature and increasing UV exposure durations. Signals were more sensitive to the former condition, suggesting that chamber temperature is important for improving the TOC oxidation rates of refractory organic matter.

Pelvic insufficiency fracture after radiotherapy in patients with cervical cancer in the era of PET/CT

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong-Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.29 no.4
    • /
    • pp.269-276
    • /
    • 2011
  • Purpose: To determine the incidence, risk factors, and clinical characteristics of pelvic insufficiency fracture (PIF) in patients with cervical cancer. Materials and Methods: Between July 2004 and August 2009, 235 patients with non-metastatic cervical cancer were treated with definitive chemoradiation or postoperative radiotherapy. Among 235 patients, 117 (49.8%) underwent the first positron emission tomography/computed tomography (PET/CT) within 1 year after radiotherapy. The median radiation dose was 55 Gy (range, 45 to 60 Gy). Medical charts and imaging studies, including PET/CT, magnetic resonance imaging (MRI), CT. bone scintigraphy were reviewed to evaluate the patients with PIF. Results: Among 235 patients, 16 developed PIF. The 5-year detection rate of PIF was 9.5%. The 5-year detection rate of PIF in patients who underwent the first PET/CT within a year was 15.6%. The median time to development of PIF was 12.5 months (range, 5 to 30 months). The sites of fracture included 12 sacroiliac joints, 3 pubic rami, 3 iliac bones, and 1 femoral neck. Eleven of 16 patients having PIF complained of hip pain requiring medications. One patient required hospitalization for pain control. The significant risk factors of PIF were old age, body mass index less than 23, bone mineral density less than -3.5 SD, and the first PET/CT within a year after radiotherapy. Radiation dose and concurrent chemotherapy had no impact on PIF rate. Conclusion: PIFs were not rare after pelvic radiotherapy in cervical cancer patients in the era of PET/CT. Timely diagnosis and management of PIF can improve quality of life in patients with cervical cancer, in addition to reducing unnecessary medical expenses.