• Title/Summary/Keyword: NK55 material

Search Result 4, Processing Time 0.02 seconds

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials

  • Soygun, Koray;Bolayir, Giray;Boztug, Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.153-160
    • /
    • 2013
  • PURPOSE. This in vitro study intended to investigate the mechanical and thermal characteristics of Valplast, and of polymethyl methacrylate denture base resin in which different esthetic fibers (E-glass, nylon 6 or nylon 6.6) were added. MATERIALS AND METHODS. Five groups were formed: control (PMMA), PMMA-E glass, PMMA-nylon 6, PMMA-nylon 6.6 and Valplast resin. For the transverse strength test the specimens were prepared in accordance with ANSI/ADA specification No.12, and for the impact test ASTM D-256 standard were used. With the intent to evaluate the properties of transverse strength, the three-point bending (n=7) test instrument (Lloyd NK5, Lloyd Instruments Ltd, Fareham Hampshire, UK) was used at 5 mm/min. A Dynatup 9250 HV (Instron, UK) device was employed for the impact strength (n=7). All of the resin samples were tested by using thermo-mechanical analysis (Shimadzu TMA 50, Shimadzu, Japan). The data were analyzed by Kruskal-Wallis and Tukey tests for pairwise comparisons of the groups at the 0.05 level of significance. RESULTS. In all mechanical tests, the highest values were observed in Valplast group (transverse strength: $117.22{\pm}37.80$ MPa, maximum deflection: $27.55{\pm}1.48$ mm, impact strength: $0.76{\pm}0.03$ kN). Upon examining the thermo-mechanical analysis data, it was seen that the E value of the control sample was 8.08 MPa, higher than that of the all other samples. CONCLUSION. Although Valplast denture material has good mechanical strength, its elastic modulus is not high enough to meet the standard of PMMA materials.

Analysis of the Correlation between atrophy of exocervical epithelial cell and osteoporosis (자궁경부 상피세포위축과 골다공증의 상관관계 분석)

  • Lee, Dae-Il;Nam, Ha-Gyeong;Lee, Mi-Hwa;Gwak, Min-Jeong;Lee, Hyeon-Jeong;Lee, Su-Bae;Hong, Gwang-Seon
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.75-84
    • /
    • 2006
  • Background : Osteoporosis and atrophic cell pattern in Pap smear are frequent findings In postmenopausal women due to loss of ovarian function, The present study attempted to find out possible correlation between morphologic characteristics of Pap smear and osteoporosis. Material & methods: The subjects were 825 women(age from 35 to 80) who had undergone Pap smear and bone mineral density(BMD) at The Korea Association of Health Promotion, Seoul Branch, from March 8 to May 10, 2005. Pap smears from 825 women were reviewed and classified either mature cell pattern or atrophic cell pattern by their cytologic patterns, BMD were measured using LUNAR DPX MdIQ(Minster, Ohio, USA). BMD value of lumbar spine(Ll, L2,L3 and L4) were measured from 825 women and BMD value of proximal region off emur(neck NK, Wards triangle WT, and trochanter TR) were measured from 818 women and their bone status were classified as normal( T-sore:>-1.0), osteopenia (T-score: -l~<-2,5) and osteoporosis(T-score: ≤ -2.5). And age distribution of Pap smear, average T-value andfrequency ofsteoporo-sis of each region of the bone, percentage of osteoporosis of each boneregion by age group and changing pattern of percentage of osteopenia and osteoporosis in certain postmenopausal period were compared between mature and atrophic cell pattern. Results: Pap smears revealed total mature cell pattern 53,9%(445/825) and total atrophic cell pattern 46.1%(380/825), Percentage of mature cell pattern decreased from 98.2%(168/171)under 44 age group to 13,3%(17/128) over 65 age group and mature cell pattern increased from 1.8%(3/171) under 44 age group to 86.7%(111/128) oyer 65 age group. Mean T-value of each region of lumbar spine and femur of mature cell pattern were lower than that of atrophic cell pattern about -1,5. And osteoporosis has noted in atrophic cell pattern showing odds ratio Ll 13.9, L2 15.3, L3 12.0, L4 10,4, UK 6.7, WT 10.9 and TR 4.1.Atrophic cell pattern started to increase after 45 years of age and osteoporosis of a trophic cell pattern started after 55 years of age. During 50 to 64 years of age period, L3, L4 and WT revealed parallel increased of osteopenia and osteoporosis and Ll, L2 revealed decreased of osteopenia and increased of osteoporosis. nia Conclusion: Above findings suggest that atrophic cell pattern of Pap smear precedes osteoporosis about 10 years and one of predictor of osteoporosis.

  • PDF