• Title/Summary/Keyword: NIR spectroscopy

Search Result 466, Processing Time 0.026 seconds

Determination of water content in alcohol by portable near infrared (NIR) system (휴대용 분광분석기를 이용한 알코올 중에 함유되어 있는 물의 측정)

  • Ahn, Jhii-Weon;Woo, Young-Ah;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • In this study, water content in the mixture of methanol and ethanol was nondestructively measured by near infrared (NIR) spectroscopy. Two types of NIR instruments, portable NIR system with a photo-diode array and scanning type NIR spectrometer were used and the calibration results were compared. Partial least squares regression (PLSR) was applied for the calibration and validation for the quantitative analysis. The calibration results from both instruments showed good correlation with actual values. The calibration with the use of PLS model predicted water concentration with a standard error of prediction (SEP) of 0.10% and 0.12% for photo diode array and scanning type, respectively. During 6 days, routine analyses for 3%, 5% and 7% water in ethanol solution with 2% methanol were performed to validate the robustness of the developed calibration model. The routine analyses showed good results with coefficient of variation (CV) of within 3% for both types of NIR spectrometers. This study showed that the rapid determination of water in the mixture of methanol and ethanol was successfully performed by NIR spectroscopy and the performance of the portable NIR system with a photo diode array detector was comparable to that of the scanning type NIR spectrometer.

Discrimination of Alismatis Rhizoma According to Geographical Origins using Near Infrared Spectroscopy (근적외선분광법을 이용한 택사의 산지 판별법 연구)

  • Lee, Dong Young;Kim, Seung Hyun;Kim, Hyo Jin;Sung, Sang Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.44 no.4
    • /
    • pp.344-349
    • /
    • 2013
  • Near infrared spectroscopy (NIRS) combined with multivariate analysis was used to discriminate the geographical origin of Alisma orientale from Korea (n=94) and China (n=72). Two-thirds of samples were selected randomly for the training set, and one-third of samples for the test set. Second derivative was used for the pretreatment of NIR spectra. Partial least square discriminant analysis (PLS-DA) models correctly discriminated 100% of the Korean and Chinese A. orientale samples. These results demonstrate the potential use of NIR spectroscopy combined with multivariate analysis as a rapid and accurate method to discriminate A. orientale according to their geographical origin.

NEAR INFRARED BIO-SPECTROSCOPY : APPROACHES FOR MEASUREMENTS IN CRITICAL CARE

  • Burns, David
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2102-2102
    • /
    • 2001
  • Near infrared, diffuse reflectance spectroscopy has shown significant potential for in vitro and in vivo assessment of metabolic status. However, the complexity of living samples can lead to ambiguous results. This presentation will focus on methods that provide controls for scattering and absorption estimation in tissue. For robust estimations, normalization procedures will be shown which can greatly improve interpretability of results. Normalization based on time, location and spectral property will be shown with data from models, tissue phantoms and in vivo measurements. In particular, interpretation of NIR spectra associated with major respiratory constituents will be examined. Measurement of constituents such as hemoglobin, myoglobin, tissue edema, and lactate will be shown. Results suggest that NIR may provide a valuable tool for physiological monitoring in critical care research and practice.

  • PDF

Potential of near infrared spectroscopy for non-destructive estimation of soluble solids in growing melons

  • Ito, Hidekazu;Morimoto, Susumu;Yamauchi, Ryougo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1525-1525
    • /
    • 2001
  • Non-destructive determination of soluble solids(Brix) in harvested fruits using near infrared(hereafter, NIR) spectroscopy has been reported by many researchers. We have just reported on non-destructive estimation of Brix in harvested melons using a NIR Systems Model 6500 spectrophotometer(Ito et al., 2000). There is a melon cultivar that is difficult to judge the harvest time from the external appearance. If we can determine Brix in growing fruits non-destructively in the field, immature fruits will not be harvested. A portable m spectrophotometer for field use has been just developed by Kubota Corporation. The spectral data of growing melons were measured by the portable spectrophotometer. A commercial program was used for multiple linear regression analysis. Brix in growing melons could be estimated by a multiple regression equation calibrated with harvested melons. Absorbances of 906 and 874 nm were included as the independent variables in the multiple regression equation, and these wavelengths are key wavelengths for non-destructive Brix determination.

  • PDF

Quality Prediction of Alfalfa Hay by Near Infraced Recfletance Spectroscopy (NIRS) (Near Infraced Recfletance Spectroscopy ( NIRS ) 에 의한 알팔파 건초의 품질 평가)

  • ;N. P. Martin
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.9 no.3
    • /
    • pp.163-167
    • /
    • 1989
  • Near infrared reflectance spectroscopy (NIRS) analysis of commercial farm alfalfa hay for crude prowin (CP), neutral detergent fiber(NDF), and acid detergent fiber(ADF) was compared with wet chemistry results. There were no differences between NIRS and wet chemistry results in CP and ADF content, but there were differences (P <.05) between NIRS and wet chemistry results for sample No.2, 4, 5 in NDF content.

  • PDF

IN-LINE NIR SPECTROSCOPY AS A TOOL FOR THE CONTROL OF FERMENTATION PROCESSES IN THE FERMENTED MEATS INDUSTRY

  • Tamburini, Elena;Vaccari, Giuseppe;Tosi, Simona;Trilli, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3104-3104
    • /
    • 2001
  • The research described here was undertaken with the aim of monitoring, optimizing and ultimately controlling the production of heterofermentative microbes used as starters in the salami industry. The use of starter cultures in the fermented meats industry is a well-established technique used to shorten and standardize the ripening process, and to improve and control the organoleptic quality of the final product. Starter cultures are obtained by the submerged cultivation of suitable microorganisms in stirred, and sometimes aerated, fermenters where monitoring of key physiological parameters such as the concentration of biomass, substrates and metabolites suffers from the general lack of real-time measurement techniques applicable to aseptic processes. In this respect, the results of the present work are relevant to all submerged fermentation processes. Previous work on the application of on-line NIR spectroscopy to the lactic acid fermentation (Dosi et al. - Monreal NIR1995) had successfully used a system based on a measuring cell included in a circulation loop external to the fermenter. The fluid handling and sterility problems inherent in an external circulation system prompted us to explore the use of an in-line system where the NIR probe is immersed in the culture and is thus exposed to the hydrodynamic conditions of the stirred and aerated fluid. Aeration was expected to be a potential source of problems in view of the possible interference of air bubbles with the measurement device. The experimental set-up was based on an in-situ sterilizable NIR probe connected to the instrument by means of an optical fiber bundle. Preliminary work was carried out to identify and control potential interferences with the measurement, in particular the varying hydrodynamic conditions prevailing at the probe tip. We were successful in defining the operating conditions of the fermenter and the geometrical parameters of the probe (flow path, positioning, etc.) were the NIR readings were reliable and reproducible. The system thus defined was then used to construct and validate calibration curves for tile concentration of biomass, carbon source and major metabolites of two different microorganisms used as salami starters. Real-time measurement of such parameters coupled with the direct interfacing of the NIR instrument with the PC-based measurement and control system of the fermenter enabled the development of automated strategies for the interactive optimization of the starter production process.

  • PDF

Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source (음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구)

  • Jang, Hansol;Kim, Gyeong Hun;Han, Ga-Hee;Cho, Jaedu;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Time-encoded near-infrared spectroscopy (NIRS) system is proposed, based on a near-infrared (NIR) swept laser source, for comparison to the conventional NIRS method using a detector-type spectrometer. The cavity of the NIR swept laser source consists of a semiconductor optical amplifier (SOA) with a gain region around 800 nm, and several fiber-optic components. To change the output wavelength in time using an applied electric radio-frequency signal, an acousto-optic tunable filter (AOTF) is introduced in the fiber ring cavity configuration. To demonstrate the feasibility of an NIR swept laser source for NIRS imaging, the spectroscopic comparison of two kinds of absorbance-measuring systems a detector-type spectrometer using a white light source, and a source-type spectrometer using an NIR swept laser is successfully performed with an NIR-absorbing dye.

Partial Least Squares Analysis on Near-Infrared Absorbance Spectra by Air-dried Specific Gravity of Major Domestic Softwood Species

  • Yang, Sang-Yun;Park, Yonggun;Chung, Hyunwoo;Kim, Hyunbin;Park, Se-Yeong;Choi, In-Gyu;Kwon, Ohkyung;Cho, Kyu-Chae;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • Research on the rapid and accurate prediction of physical properties of wood using near-infrared (NIR) spectroscopy has attracted recent attention. In this study, partial least squares analysis was performed between NIR spectra and air-dried specific gravity of five domestic conifer species including larch (Larix kaempferi), Korean pine (Pinus koraiensis), red pine (Pinus densiflora), cedar (Cryptomeria japonica), and cypress (Chamaecyparis obtusa). Fifty different lumbers per species were purchased from the five National Forestry Cooperative Federations of Korea. The air-dried specific gravity of 100 knot- and defect-free specimens of each species was determined by NIR spectroscopy in the range of 680-2500 nm. Spectral data preprocessing including standard normal variate, detrend and forward first derivative (gap size = 8, smoothing = 8) were applied to all the NIR spectra of the specimens. Partial least squares analysis including cross-validation (five groups) was performed with the air-dried specific gravity and NIR spectra. When the performance of the regression model was expressed as $R^2$ (coefficient of determination) and root mean square error of calibration (RMSEC), $R^2$ and RMSEC were 0.63 and 0.027 for larch, 0.68 and 0.033 for Korean pine, 0.62 and 0.033 for red pine, 0.76 and 0.022 for cedar, and 0.79 and 0.027 for cypress, respectively. For the calibration model, which contained all species in this study, the $R^2$ was 0.75 and the RMSEC was 0.37.

Unambiguous Evidence for Phase Transitions of Oleic Acid in Pure Liquid State by Near-Infrared Spectroscopy and Pricipan Comaonent Analysis

  • Nobuya Yokochi;Makio Iwahashi;Masao Suzuki;Yukihiro Ozaki
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.21-27
    • /
    • 2000
  • Temperature-dependent changes in near-infrared (NIR) spectra have been measured for oleic acid, and nonanoic acid in the pure liquid state. Particular attention has been paid to the 5400-4800 cm$\^$-1/ region where a number of combination bands appear. The NIR spectra of oleic acid show that a band at 5303 cm$\^$-1/ increases with temperature while that at 5270 cm/sup-1/ decreases. It ha been found from their second derivative spectra that these spectral changes take place stepwisely with two break points at 30 and 53$\^{C}$, which correspond to the phase transition temperatures oleic acid reported previously. Principle component analysis (PCA) has been carried out for the NIR spectra of oleic acid in the 5400-4800 cm$\^$-1/ region measured over a temperature range of 15-80$\^{C}$. core plots of the first and second principal components (PCs) show that the NIR spectra are classified into three groups; the spectra measured in the temperature range of 15-30$\^{C}$, those in the range of 31-53$\^{C}$, and those in the range of 54-80$\^{C}$. These temperature ranges correspond to those for quasi-smectic liquid crystal, disordered liquid crystal, and isotropic liquid of oleic acid in the pure liquid state. In other words, PCA provides unambiguous evidence for the phase transitions. similar studies have been carried out for petroselinic acid and nonanoic acid in the pure liquid states, but they do not show any evidence for phase transitions.

Application of Near-Infrared Reflectance Spectroscopy (NIR) Method to Rapid Determination of Seed Protein in Coarse Cereal Germplasm

  • Lee, Young-Yi;Kim, Jung-Bong;Lee, Ho-Sun;Lee, Sok-Young;Gwag, Jae-Gyun;Ko, Ho-Cheol;Huh, Yun-Chan;Hyun, Do-Yoon;Kim, Chung-Kon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.4
    • /
    • pp.357-364
    • /
    • 2010
  • Kjeldahl method used in many materials from various plant parts to determine protein contents, is laborious and time-consuming and utilizes hazardous chemicals. Near-infrared (NIR) reflectance spectroscopy, a rapid and environmentally benign technique, was investigated as a potential method for the prediction of protein content. Near-infrared reflectance spectra(1100-2400 nm) of coarse cereal grains(n=100 for each germplasm) were obtained using a dispersive spectrometer as both of grain itself and flour ground, and total protein contents determined according to Kjeldahl method. Using multivariate analysis, a modified partial least-squares model was developed for prediction of protein contents. The model had a multiple coefficient of determination of 0.99, 0.99, 0.99, 0.96 and 0.99 for foxtail millet, sorghum, millet, adzuki bean and mung bean germplasm, respectively. The model was tested with independent validation samples (n=10 for each germplasm). All samples were predicted with the coefficient of determination of 0.99, 0.99, 0.99, 0.91 and 0.99 for foxtail millet, sorghum, millet, adzuki bean and mung bean germplasm, respectively. The results indicate that NIR reflectance spectroscopy is an accurate and efficient tool for determining protein content of diverse coarse cereal germplasm for nutrition labeling of nutritional value. On the other hands appropriate condition of cereal material to predict protein using NIR was flour condition of grains.