• Title/Summary/Keyword: NIR spectrometer

Search Result 89, Processing Time 0.024 seconds

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

Silicon Prism-based NIR Spectrometer Utilizing MEMS Technology

  • Jung, Dong Geon;Son, Su Hee;Kwon, Sun Young;Lee, Jun Yeop;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2017
  • Recently, infrared (IR) spectrometers have been required in various fields such as environment, safety, mobile, automotive, and military. This IR dispersive sensor detection method of substances is widely used. In this study, we fabricated a silicon (Si) prism-based near infrared (NIR) spectrometer utilizing micro electro mechanical system (MEMS) technology. Si prism-based NIR spectrometer utilizing MEMS technology consists of upper, middle, and lower substrates. The upper substrate passes through the incident IR ray selectively. The middle substrate, acting as a prism, disperses and separates the incident IR beam. The lower substrate has an amorphous Si (a-Si)-based bolometer array to detect the IR spectrum. The fabricated Si prism-based NIR spectrometer utilizing MEMS technology has the advantage of a simple structure, easy fabrication steps, and a wide NIR region operating range.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Design and Fabrication of an NIR Grism Si Optical Area Sensor Spectrometer with In-band Reference Wavelength (대역 내 기준 파장을 갖는 근적외선 그리즘 실리콘 광 면 센서 분광기 설계 및 제작)

  • Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • An NIR grism Si optical area sensor spectrometer with in-band reference wavelength is designed and fabricated. It is composed of a transmission type diffraction grating (spatial density 300 line/mm), a rectangular N-BK7 prism (apex angle 30 degree), NIR filter(cutoff wavelength 720 nm), an imaging convex lens(focal length 50 mm F1.8) and an IR modified DSLR camera (Canon EOS40D) of Si optical area sensor ($3,888{\times}2,592$ pixels, pixel size $5.710{\mu}m$). "In-band reference wavelength function" is implemented using non-dispersive 0th diffraction order optical beam. The NIR grism spectrometer is tested in a laboratory using a halogen lamp and a Neon lamp. And the spectrometer is used in an astronomy field for obtaining the planet Jupiter NIR spectrum. In-band reference wavelength i.e. un-deviation wavelength is 846 nm, an wavelength resolution is 0.3027 nm/pixel, an wavelength resolving power is 2,794 and an wavelength range is 650~1,000 nm.

Food Powder Classification Using a Portable Visible-Near-Infrared Spectrometer

  • You, Hanjong;Kim, Youngsik;Lee, Jae-Hyung;Jang, Byung-Jun;Choi, Sunwoong
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.186-190
    • /
    • 2017
  • Visible-near-infrared (VIS-NIR) spectroscopy is a fast and non-destructive method for analyzing materials. However, most commercial VIS-NIR spectrometers are inappropriate for use in various locations such as in homes or offices because of their size and cost. In this paper, we classified eight food powders using a portable VIS-NIR spectrometer with a wavelength range of 450-1,000 nm. We developed three machine learning models using the spectral data for the eight food powders. The proposed three machine learning models (random forest, k-nearest neighbors, and support vector machine) achieved an accuracy of 87%, 98%, and 100%, respectively. Our experimental results showed that the support vector machine model is the most suitable for classifying non-linear spectral data. We demonstrated the potential of material analysis using a portable VIS-NIR spectrometer.

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.

Determination of water content in alcohol by portable near infrared (NIR) system (휴대용 분광분석기를 이용한 알코올 중에 함유되어 있는 물의 측정)

  • Ahn, Jhii-Weon;Woo, Young-Ah;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • In this study, water content in the mixture of methanol and ethanol was nondestructively measured by near infrared (NIR) spectroscopy. Two types of NIR instruments, portable NIR system with a photo-diode array and scanning type NIR spectrometer were used and the calibration results were compared. Partial least squares regression (PLSR) was applied for the calibration and validation for the quantitative analysis. The calibration results from both instruments showed good correlation with actual values. The calibration with the use of PLS model predicted water concentration with a standard error of prediction (SEP) of 0.10% and 0.12% for photo diode array and scanning type, respectively. During 6 days, routine analyses for 3%, 5% and 7% water in ethanol solution with 2% methanol were performed to validate the robustness of the developed calibration model. The routine analyses showed good results with coefficient of variation (CV) of within 3% for both types of NIR spectrometers. This study showed that the rapid determination of water in the mixture of methanol and ethanol was successfully performed by NIR spectroscopy and the performance of the portable NIR system with a photo diode array detector was comparable to that of the scanning type NIR spectrometer.

The Quantification and Validation of Loxoprofen using Near-infrared(NIR) Spectrum Method (근적외부스펙트럼 측정법을 이용한 록소프로펜의 정량화 및 밸리데이션)

  • Choi, Sung-Up
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.396-401
    • /
    • 2014
  • In this study, we used NIR spectrum method instead of conventional HPLC method to shorten the analysis and manufacturing time of the loxoprofen products. Loxoprofen mixtures with other pharmaceutical additives were prepared and evaluated by the NIR spectrometer and the HPLC system. Validation of both methods was performed for specificity, accuracy and precision. NIR spectrometer method was validated and revealed proper results for the in-process quality control in the pharmaceutical field. In conclusion, NIR spectrometry can be replaced by HPLC method.

Determination of NaOH, $Na_2CO_3$ and $Na_2S$ Concentration in a Naphtha Cracking Process by FT-NIR Spectroscopy (FT-NIR를 이용한 Naphtha Cracking 공정중 NaOH, $Na_2CO_3$$Na_2S$ 정량분석)

  • Jang, Mijin;Kim, Hyunwook;Cho, Ilyoung
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.448-451
    • /
    • 1998
  • The feasibility of using FT-NIR (Fourier Transform Near Infrared) spectrometer to measure NaOH, $Na_2CO_3$ and $Na_2S$ concentration in a naphtha cracking process, and an outline of the method development to identify spectral feature of the hydroxide whose band is overlapped by a strong water absorption were demonstrated. For measuring NaOH, $Na_2CO_3$ and $Na_2S$, FT-NIR spectrometer is a rapid and possible alternative to the current titration method with a standard deviation of 0.1.

  • PDF

The study for analysis of acidity and moisture in paper record by mobile small NIR spectrometer (이동 가능한 소형 근적외선 분광 분석기를 사용한 종이 기록물 내 산성도 및 함수율 분석에 대한 연구)

  • Lee, Chang Yong;Kim, Chan Bong;Lee, Seong Uk;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.370-374
    • /
    • 2012
  • As for quality evaluation of paper records, it is very important to measure acidity and moisture in paper. In the case important paper records, it should be measured directly in field. But ISO standard analytical method would be limited to measure directly in field for quality evaluation of paper records until now. Therefore it could be to use mobile small NIR spectrometer for being analyzed by direct and non-invasive method in field. The wavelength range of small spectrometer has from 900 to 1700 nm, and the surface of paper could be measured by diffused reflected optical fiber probe. Thus, the acidity and moisture could be analyzed on the paper record with from 1970 to 2003. As the result, it could be confirmed to have each more than 0.9 as the correlation of acidity and moisture. Thus, it will be possible to develope the evaluation system of paper record with mobile small NIR spectrometer and optical fiber by the result.